ABB 07KR240 GJV3072402R1 Product Documentation
Product Introduction
The ABB 07KR240 GJV3072402R1 is a high-performance surge protection device (SPD) designed to safeguard electrical and electronic equipment from voltage spikes and transient overvoltages. It is part of ABB’s OVR surge protection series, which is widely used in industrial, commercial, and residential applications. This device ensures reliable protection against lightning strikes and switching surges, enhancing the longevity and performance of connected systems.
The 07KR240 model features a robust design with a quick response time, ensuring minimal downtime and maximum protection. Its compact form factor allows for easy integration into various electrical setups.
Product Advantages
- High Surge Current Capacity: Capable of handling large surge currents, ensuring reliable protection.
- Fast Response Time: Reacts swiftly to transient voltages, minimizing potential damage.
- Durable Construction: Built with high-quality materials for long-term performance.
- Visual Status Indication: Equipped with an indicator for easy monitoring of operational status.
- Wide Application Range: Suitable for low-voltage power distribution systems.
- Compliance with Standards: Meets international safety and performance standards.
Technical Parameters
Parameter | Value |
---|---|
Model Number | 07KR240 GJV3072402R1 |
Type | Surge Protection Device (SPD) |
Rated Voltage (Un) | 240V AC |
Max Continuous Voltage (Uc) | 320V AC |
Nominal Discharge Current (In) | 20kA (8/20μs) |
Max Discharge Current (Imax) | 40kA (8/20μs) |
Voltage Protection Level (Up) | ≤1.5kV |
Response Time | <25ns |
Operating Temperature | -40°C to +80°C |
Dimensions (L x W x H) | 90mm x 36mm x 66mm |
Weight | 0.25kg |
Protection Class | IP20 |
Connection Type | Screw Terminal |
Applications
- Industrial Power Systems: Protects machinery and control systems from surges.
- Commercial Buildings: Ensures safety for office equipment and HVAC systems.
- Residential Installations: Safeguards household electronics and appliances.
- Telecommunications: Used in communication infrastructure to prevent damage from surges.
- Renewable Energy Systems: Protects solar inverters and wind power systems.
Recommended Companion Products
- ABB OVR T1 40 275 – For primary surge protection in high-risk areas.
- ABB OVR T2 40 275 – Secondary protection for enhanced safety.
- ABB OVR PV 600 – Designed for photovoltaic systems.
- ABB DS241 – Surge arrester for data line protection.
- ABB 2CSR275101R1164 – Auxiliary contact block for SPD monitoring.
- ABB S201 Circuit Breaker – Provides overcurrent protection in conjunction with SPDs.
Installation Instructions
- Mounting: Secure the device on a DIN rail within the distribution panel.
- Wiring: Connect the phase (L) and neutral (N) wires to the designated terminals.
- Grounding: Ensure proper grounding for effective surge dissipation.
- Verification: Check the status indicator to confirm proper installation.
- Maintenance: Regularly inspect for physical damage or indicator status changes.
Recommended Related Models in the Same Series
Model | Voltage (Un) | Max Current (Imax) | Protection Level (Up) | Dimensions (mm) | Weight |
---|---|---|---|---|---|
ABB 07KR120 | 120V AC | 40kA | ≤1.2kV | 90x36x66 | 0.23kg |
ABB 07KR480 | 480V AC | 40kA | ≤2.5kV | 90x36x66 | 0.26kg |
ABB 07KR600 | 600V AC | 40kA | ≤3.0kV | 90x36x66 | 0.27kg |
ABB OVR T1 40 275 | 275V AC | 40kA | ≤1.4kV | 72x90x65 | 0.30kg |
ABB OVR T2 40 275 | 275V AC | 40kA | ≤1.4kV | 72x90x65 | 0.30kg |
ABB OVR PV 600 | 600V DC | 20kA | ≤3.2kV | 90x36x66 | 0.28kg |
Top 8 Popular ABB Models
Model | Type | Voltage | Current Rating | Dimensions (mm) | Weight |
---|---|---|---|---|---|
ABB S201 | Circuit Breaker | 230V | 16A | 90x18x67 | 0.15kg |
ABB DS241 | Data Line SPD | 24V DC | 5kA | 22x56x40 | 0.10kg |
ABB F202 | Residual Current Device | 230V | 25A | 90x36x67 | 0.20kg |
ABB 2CSR275101R1164 | Auxiliary Contact | 240V | 6A | 18x45x55 | 0.08kg |
ABB OVR BT24 | Telecom SPD | 24V DC | 10kA | 22x56x40 | 0.12kg |
ABB OVR T1+T2 40 | Combined SPD | 275V | 40kA | 144x90x65 | 0.60kg |
ABB OVR PV 1000 | PV SPD | 1000V DC | 20kA | 90x36x66 | 0.30kg |
ABB MS116 | Switch Disconnector | 400V | 16A | 45x78x64 | 0.25kg |
FAQ (Frequently Asked Questions)
Q1: What is the lifespan of the ABB 07KR240 SPD?
A1: The lifespan depends on exposure to surges, but under normal conditions, it can last 5-10 years.
Q2: Can this SPD be used in outdoor installations?
A2: No, it is rated for indoor use (IP20). For outdoor applications, an additional enclosure is required.
Q3: How do I know if the SPD has failed?
A3: The status indicator will show a red or off state when the device is no longer functional.
Q4: Is the ABB 07KR240 suitable for DC systems?
A4: No, this model is designed for AC systems only. For DC, consider the OVR PV series.
Q5: What is the replacement procedure for a failed SPD?
A5: Disconnect power, remove the old unit, and install a new one following the same wiring configuration.
Q6: Can multiple SPDs be connected in parallel?
A6: Yes, for enhanced protection, but they should be coordinated (e.g., T1 + T2 configuration).
ABB 07KR240 GJV3072402R1 programmable logic controller (PLC) module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |