Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introduction
The ABB 07KT98B GIR5253100R3160 is a high-performance industrial circuit breaker designed for reliable protection and control of electrical circuits. It is part of ABB’s renowned series of circuit breakers, known for their durability, precision, and advanced safety features. This model is suitable for a wide range of applications, including industrial automation, power distribution, and machinery protection.
The breaker incorporates advanced trip technology, ensuring quick response to overloads and short circuits, thereby minimizing downtime and equipment damage. Its robust construction ensures long-term performance even in harsh environments.
Product Advantages
- High Reliability – Engineered for consistent performance under varying load conditions.
- Advanced Protection – Features precise tripping mechanisms for overload and short-circuit protection.
- Durability – Constructed with high-quality materials for extended service life.
- Easy Installation – Modular design allows for straightforward integration into existing systems.
- Wide Compatibility – Works seamlessly with various ABB accessories and panels.
- Safety Compliance – Meets international standards for electrical safety.
Technical Parameters
Parameter | Value |
---|---|
Model | ABB 07KT98B GIR5253100R3160 |
Rated Current | 100A |
Rated Voltage | 690V AC / 250V DC |
Breaking Capacity | 36kA at 415V AC |
Poles | 3P (3-Pole) |
Trip Unit | Thermal-Magnetic |
Mounting | Fixed |
Dimensions | 240 x 140 x 85 mm |
Weight | 1.6 kg |
Operating Temp. | -25°C to +60°C |
Standards | IEC 60947-2, CE Certified |
Applications
The ABB 07KT98B GIR5253100R3160 is widely used in:
- Industrial control panels
- Power distribution systems
- Motor protection circuits
- HVAC systems
- Renewable energy installations
- Machinery and automation systems
Compatible Accessories & Models
This breaker can be paired with:
- Mounting Adapters: ABB 1SDA072510R1
- Auxiliary Contacts: ABB 1SCA022253R1001
- Shunt Releases: ABB 1SDA072616R1
- Terminal Covers: ABB 1SDA072817R1
Installation Instructions
- Power Off – Ensure the circuit is de-energized before installation.
- Mounting – Secure the breaker onto a DIN rail or panel using appropriate fasteners.
- Wiring – Connect the input and output terminals as per the wiring diagram.
- Testing – After installation, perform a functional test to verify proper operation.
- Safety Check – Confirm all connections are tight and insulated.
Recommended Similar Models (Same Series)
Model | Rated Current | Voltage | Breaking Capacity | Poles | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
ABB 07KT96B GIR5252100R3160 | 63A | 690V AC | 25kA | 3P | 90 x 135 x 65 | 0.9 kg |
ABB 07KT97B GIR5252200R3160 | 80A | 690V AC | 36kA | 3P | 95 x 140 x 68 | 1.0 kg |
ABB 07KT99B GIR5254100R3160 | 125A | 690V AC | 36kA | 3P | 110 x 150 x 75 | 1.5 kg |
ABB 07KT95B GIR5251100R3160 | 50A | 690V AC | 25kA | 3P | 85 x 130 x 60 | 0.8 kg |
ABB 07KT94B GIR5250100R3160 | 40A | 690V AC | 25kA | 3P | 80 x 125 x 55 | 0.7 kg |
ABB 07KT93B GIR5249100R3160 | 32A | 690V AC | 25kA | 3P | 75 x 120 x 50 | 0.6 kg |
Recommended Popular ABB Models
Model | Rated Current | Voltage | Breaking Capacity | Poles | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
ABB S201M-C25 | 25A | 440V AC | 6kA | 1P | 18 x 90 x 67 | 0.2 kg |
ABB Tmax XT2N160 | 160A | 690V AC | 36kA | 3P | 150 x 180 x 85 | 2.5 kg |
ABB DS260C | 60A | 240V AC | 10kA | 2P | 72 x 90 x 70 | 0.5 kg |
ABB SH202L-C25 | 25A | 400V AC | 4.5kA | 2P | 36 x 90 x 67 | 0.3 kg |
ABB Emax E2.2N1600 | 1600A | 690V AC | 65kA | 3P | 300 x 400 x 150 | 15 kg |
ABB F202A-63/0.03 | 63A | 400V AC | 10kA | 2P | 72 x 90 x 70 | 0.6 kg |
ABB MS116-1.6 | 16A | 230V AC | 6kA | 1P | 18 x 90 x 67 | 0.15 kg |
ABB XT1N160 | 160A | 440V AC | 36kA | 3P | 140 x 170 x 80 | 2.0 kg |
FAQ (Frequently Asked Questions)
Q1: What is the operating temperature range of the ABB 07KT98B GIR5253100R3160?
A1: The breaker operates within -25°C to +60°C.
Q2: Can this breaker be used for DC applications?
A2: Yes, it supports 250V DC in addition to 690V AC.
Q3: What is the breaking capacity at 415V AC?
A3: The breaking capacity is 36kA at 415V AC.
Q4: Is this breaker compatible with DIN rail mounting?
A4: Yes, it can be mounted on a standard DIN rail.
Q5: Does this model include a thermal-magnetic trip unit?
A5: Yes, it features a thermal-magnetic trip mechanism.
Q6: What standards does this breaker comply with?
A6: It meets IEC 60947-2 and is CE certified.
ABB 07KT98B GIR5253100R3160 Basic Unit
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |