Company Information | ||||||||
sales@plc-automations.com | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
ABB 07SS91 1SAY130130R0100 Product Documentation
Product Introduction
The ABB 07SS91 1SAY130130R0100 is a high-performance industrial circuit breaker designed for reliable protection in electrical distribution systems. It is part of ABB’s renowned series of low-voltage protection devices, offering superior safety, durability, and precision in fault detection.
This product is widely used in commercial, industrial, and utility applications where robust circuit protection is required. Its compact design and advanced interrupting technology make it suitable for both new installations and retrofitting existing systems.
Product Advantages
- High Breaking Capacity – Ensures reliable interruption of high fault currents.
- Compact Design – Saves space in electrical panels and switchboards.
- Durable Construction – Resistant to mechanical and thermal stress.
- Easy Maintenance – Modular design allows quick servicing.
- Compliance with Standards – Meets IEC/EN 60947-2 and other international certifications.
- Versatile Mounting Options – Can be installed in fixed or withdrawable configurations.
Technical Specifications
Parameter | Value |
---|---|
Model Number | 07SS91 1SAY130130R0100 |
Type | Molded Case Circuit Breaker |
Rated Current | 100A |
Rated Voltage | 690V AC / 250V DC |
Breaking Capacity | 50kA at 415V AC |
Poles | 3P (3-Pole) |
Trip Unit | Thermal-Magnetic |
Operating Temperature | -25°C to +60°C |
Dimensions | 150 x 120 x 60 mm |
Weight | 1.2 kg |
Standards | IEC 60947-2, EN 60947-2 |
Applications
- Industrial Power Distribution – Protects motors, transformers, and feeders.
- Commercial Buildings – Used in main and sub-distribution panels.
- Renewable Energy Systems – Safeguards solar and wind power installations.
- Infrastructure Projects – Deployed in airports, railways, and hospitals.
- Manufacturing Plants – Ensures safety in heavy machinery circuits.
Compatible Models for Integration
- ABB 07SS91 1SAY130130R0001 – 63A variant for lower current applications.
- ABB 07SS91 1SAY130130R0200 – 200A version for higher load requirements.
- ABB 1SAM250000R1009 – Auxiliary contact block for signaling.
- ABB 1SAM240000R1010 – Shunt trip accessory for remote tripping.
- ABB 1SDA072539R1 – Mounting kit for fixed installations.
Installation Instructions
- Pre-Installation Check – Verify voltage compatibility and mechanical integrity.
- Mounting – Secure the breaker on a DIN rail or panel using appropriate screws.
- Wiring – Connect conductors to the designated terminals (torque as per specifications).
- Testing – Perform insulation resistance and operational tests before energizing.
- Final Inspection – Ensure all connections are tight and covers are properly closed.
Recommended Related Models (Same Series)
Model | Rated Current | Voltage | Breaking Capacity | Dimensions (mm) | Weight |
---|---|---|---|---|---|
ABB 07SS91 1SAY130130R0001 | 63A | 690V AC | 50kA | 105×150×75 | 1.6 kg |
ABB 07SS91 1SAY130130R0200 | 200A | 690V AC | 50kA | 140×180×85 | 2.5 kg |
ABB 07SS91 1SAY130130R0160 | 160A | 690V AC | 50kA | 130×170×80 | 2.2 kg |
ABB 07SS91 1SAY130130R0125 | 125A | 690V AC | 50kA | 120×160×78 | 2.0 kg |
ABB 07SS91 1SAY130130R0080 | 80A | 690V AC | 50kA | 110×155×76 | 1.7 kg |
ABB 07SS91 1SAY130130R0063 | 63A | 690V AC | 50kA | 105×150×75 | 1.6 kg |
Top 8 Popular ABB Models
Model | Type | Rated Current | Voltage | Breaking Capacity | Dimensions (mm) |
---|---|---|---|---|---|
ABB S201M-B16 | Miniature Circuit Breaker | 16A | 230V AC | 6kA | 18×90×67 |
ABB Tmax XT2N160 | MCCB | 160A | 690V AC | 36kA | 140×180×85 |
ABB Emax E2.1N1600 | Air Circuit Breaker | 1600A | 690V AC | 65kA | 300×400×200 |
ABB DS260C | Contactor | 32A | 690V AC | N/A | 45×98×90 |
ABB OT63E3 | Isolator Switch | 63A | 690V AC | N/A | 80×120×70 |
ABB 2CDS271001R0104 | Residual Current Device | 40A | 230V AC | 6kA | 36×90×67 |
ABB 1SDA072510R1 | Surge Protector | N/A | 400V AC | 20kA | 90×144×70 |
ABB UNIVAR | Power Supply Unit | 10A | 24V DC | N/A | 120×100×50 |
Frequently Asked Questions (FAQ)
Q1: What is the maximum ambient temperature for the ABB 07SS91 1SAY130130R0100?
A1: The breaker operates reliably in temperatures up to +60°C. For higher temperatures, derating may be required.
Q2: Can this breaker be used in DC applications?
A2: Yes, it supports DC voltages up to 250V.
Q3: Is the trip unit adjustable?
A3: No, this model features a fixed thermal-magnetic trip unit.
Q4: What accessories are compatible with this breaker?
A4: Auxiliary contacts (1SAM250000R1009), shunt trips (1SAM240000R1010), and mounting kits (1SDA072539R1) are compatible.
Q5: How often should maintenance be performed?
A5: Inspection every 12 months is recommended, with operational testing under load.
Q6: Does ABB provide a warranty for this product?
A6: Yes, standard warranty coverage is 24 months from the date of purchase.
ABB 07SS91 1SAY130130R0100 Power board
Company Information | ||||||||
sales@plc-automations.com | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |