ABB 88FT05 GJR2393100R1200
Product Introduction
The ABB 88FT05 GJR2393100R1200 is a high-performance communication interface module designed for ABB’s automation systems. Built for robust and reliable industrial control environments, this unit ensures seamless signal transmission between field devices and control systems. Its modular design and superior communication capabilities make it a critical component in ABB’s Symphony and INFI 90 process control platforms.
The 88FT05 provides both analog and digital communication pathways, serving as an intermediary between various subsystems. With its integrated circuitry and advanced diagnostics, it supports system integrity while minimizing downtime. This product is widely adopted in large-scale industries such as oil & gas, chemical, power generation, and water treatment, where process reliability is critical.
Product Advantages
-
High Reliability: Engineered with industrial-grade components for long-term use in harsh conditions.
-
Seamless Integration: Easily integrates with ABB Symphony and INFI 90 systems, enhancing system flexibility and scalability.
-
Modular Architecture: Facilitates quick replacement and upgrades, reducing mean time to repair (MTTR).
-
Enhanced Communication: Supports robust data exchange across analog and digital interfaces.
-
Diagnostic Capability: Built-in self-monitoring functions for real-time fault detection and easier maintenance.
-
Compact Design: Optimized for space-constrained installations with minimal footprint.
Technical Specifications
Parameter | Value |
---|---|
Model Number | 88FT05 GJR2393100R1200 |
Description | Communication Interface Module |
Compatible System | ABB INFI 90, Symphony |
Voltage Supply | 24 V DC ±10% |
Power Consumption | < 5 W |
Communication Ports | Serial, RS-232/RS-485 |
Diagnostic Features | Yes (LED Indicators, Error Logging) |
Dimensions | 198x 261x 40mm |
Weight | 0.5 kg |
Operating Temperature | 0°C to +60°C |
Storage Temperature | -40°C to +85°C |
Humidity Range | 5% to 95% non-condensing |
Mounting Type | DIN Rail / Rack Mount |
Certifications | CE, UL, RoHS |
Applications
The ABB 88FT05 GJR2393100R1200 is widely used in a variety of industrial automation environments, including:
-
Power Generation Facilities: For process monitoring, generator control, and turbine automation.
-
Oil and Gas Industries: Facilitates safe and efficient production through integrated control systems.
-
Chemical Plants: Ensures accurate communication between process units and control rooms.
-
Water and Wastewater Treatment: Provides robust data communication for pump control, water quality monitoring, and SCADA systems.
-
Steel and Metal Manufacturing: Used in real-time monitoring of critical operations and machine automation.
Compatible Models
The 88FT05 works seamlessly with other ABB modules from the Symphony and INFI 90 series, including:
-
INNIS01
-
INNPM11
-
INICT03A
-
IMMPI01
-
IMMFP11
-
INFI90
These modules form part of a larger distributed control system (DCS), with each contributing specific functionalities to achieve integrated plant control.
Installation Instructions
-
Pre-Installation Check:
-
Inspect the module for visible damages.
-
Verify part number and compatibility with the existing control system.
-
-
Mounting:
-
Secure the module on a DIN rail or control rack.
-
Ensure adequate ventilation to prevent overheating.
-
-
Wiring:
-
Connect power supply (24 V DC).
-
Wire communication ports according to system architecture (RS-232/RS-485).
-
Double-check terminal connections and tighten all screws.
-
-
System Integration:
-
Configure the module within the DCS software environment.
-
Assign proper node IDs and communication parameters.
-
-
Testing:
-
Power up the system and observe diagnostic LEDs.
-
Perform loop checks and communication validation.
-
Document the setup for future maintenance reference.
-
6 Related or Series-Compatible Models
Model | Description | Voltage | Dimensions (mm) | Weight (kg) | System |
---|---|---|---|---|---|
INNIS01 | Network Interface Slave Module | 24 V DC | 102 x 240 x 190 | 1.2 | INFI 90 |
INICT03A | INFI-Net to Ethernet Communication | 24 V DC | 102 x 240 x 190 | 1.3 | Symphony / INFI |
IMMFP11 | Multi-Function Processor | 24 V DC | 102 x 240 x 190 | 1.35 | INFI 90 |
IMMPI01 | Multi-Point Interface Module | 24 V DC | 102 x 240 x 190 | 1.2 | INFI 90 |
IMDSO14 | Digital Output Module | 24 V DC | 102 x 240 x 190 | 1.1 | Symphony Plus |
INNPM11 | Network Processing Module | 24 V DC | 102 x 240 x 190 | 1.25 | INFI 90 |
8 Popular ABB Models
Model | Description | Voltage | Dimensions (mm) | Weight (kg) | System |
---|---|---|---|---|---|
CI854AK01 | PROFIBUS DP Communication Module | 24 V DC | 120 x 110 x 50 | 0.3 | AC 800M |
PM864AK01 | CPU Controller | 24 V DC | 186 x 186 x 40 | 0.6 | AC 800M |
AI810 | Analog Input Module (8 channels) | 24 V DC | 120 x 110 x 60 | 0.4 | S800 I/O |
DO810 | Digital Output Module (16 channels) | 24 V DC | 120 x 110 x 60 | 0.45 | S800 I/O |
CI801 | Communication Interface Module | 24 V DC | 120 x 110 x 50 | 0.35 | AC 800F |
PM572 | Compact PLC CPU | 24 V DC | 150 x 100 x 75 | 0.5 | ABB AC500-eCo |
TU830V1 | Compact I/O Terminal | N/A | 120 x 100 x 70 | 0.25 | S800 I/O |
CI532V02 | Communication Interface Module | 24 V DC | 100 x 100 x 60 | 0.3 | Freelance 800F |
FAQs (Q&A Format)
Q1: What system platforms is the ABB 88FT05 compatible with?
A1: The 88FT05 is designed for integration with ABB Symphony and INFI 90 control systems.
Q2: Can the 88FT05 be hot-swapped during operation?
A2: No, it is recommended to power down the system before replacing or installing the module to avoid damage or data loss.
Q3: What are the available communication protocols?
A3: The module supports RS-232 and RS-485 serial communication standards.
Q4: How do I know if the module is operating correctly?
A4: The module is equipped with diagnostic LEDs indicating status, communication activity, and fault conditions.
Q5: Is the 88FT05 suitable for outdoor use?
A5: No, it should be installed in a controlled indoor environment with protection from dust, moisture, and temperature extremes.
Q6: Where can I get technical support or firmware updates?
A6: Technical documentation, firmware, and support can be accessed through ABB’s official website or authorized ABB service providers.
ABB 88FT05 GJR2393100R1200 Station Modem Module