Product Introduction: ABB Bailey IISACO1
The ABB Bailey IISACO1 is a high-performance analog input module designed for use in the INFI 90 Distributed Control System (DCS). Developed by ABB’s renowned Bailey line, the IISACO1 module is engineered to offer accurate and reliable analog signal acquisition from field devices such as sensors and transmitters. It converts field analog signals into digital values that are further processed by the controller for process control and monitoring.
This module plays a critical role in industrial automation systems where precision, system integrity, and scalability are required. The IISACO1 is widely recognized for its robust design, high data integrity, and its seamless integration with other ABB DCS components.
Product Advantages
-
High Accuracy Analog Acquisition: Supports a variety of analog signal types with high resolution for precise monitoring.
-
Durable and Industrial-Grade Build: Designed for long-term operation in harsh environments with superior resistance to temperature and vibration.
-
Seamless Integration: Fully compatible with ABB’s INFI 90 control system, allowing smooth deployment within existing infrastructures.
-
Advanced Diagnostic Capabilities: Built-in diagnostics improve system reliability by enabling fast detection and response to faults.
-
Modular Design: Facilitates easy replacement, expansion, and maintenance within DCS architectures.
-
Low Power Consumption: Optimized for energy-efficient operation to reduce overall operational costs.
Technical Specifications
Parameter | Value |
---|---|
Module Type | Analog Input Module |
Model Number | IISACO1 |
Input Channels | 8 analog input channels |
Input Signal Range | 0-10 VDC, 4-20 mA (configurable) |
Resolution | 12-bit |
Conversion Type | Successive Approximation |
Isolation | Channel-to-channel and channel-to-system |
Operating Voltage | 24 VDC |
Power Consumption | < 5 W |
Operating Temperature | 0°C to 60°C (32°F to 140°F) |
Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
Relative Humidity | 5% to 95% (non-condensing) |
Dimensions | 72 x 144 x 381 mm |
Weight | 2.2kg |
Mounting | DIN Rail or Panel Mount |
Certifications | CE, UL, RoHS |
Applications
-
Power Generation Plants: Monitoring temperature, pressure, and flow levels in turbines and boilers.
-
Oil and Gas: Real-time acquisition of pressure and flow signals in upstream and downstream processes.
-
Chemical and Petrochemical: Precise monitoring of analog signals for safe chemical processing.
-
Water and Wastewater Treatment: Acquisition of pH, turbidity, and other sensor data.
-
Manufacturing and Process Industries: General-purpose analog data acquisition for automation and process control.
-
Pharmaceutical and Food Industries: Ensuring quality and consistency in batch and continuous processes.
Compatible Models
The IISACO1 module is typically used in conjunction with the following ABB Bailey modules and controllers:
-
INNIS21 – Network Interface Module
-
IMCPM02 – Central Processor Module
-
IMDSM04 – Digital Slave Module
-
NTCL01-A – Communication Interface
-
IMMPI01 – Multipurpose Interface Module
-
IMCIS22 – Controller Interface Slave
Installation Instructions
-
Power Down the System: Ensure all system power is safely turned off to prevent electric shock or module damage.
-
Mounting: Secure the IISACO1 module to a DIN rail or mount it onto the system chassis using the designated screw holes.
-
Wiring the Inputs: Connect analog input devices to the terminal block according to the wiring diagram in the user manual. Ensure polarity and signal type compatibility.
-
Module Address Configuration: Set the module address using DIP switches if required by the control system configuration.
-
System Integration: Insert the module into the appropriate slot in the I/O rack. Connect to the communication backplane.
-
Power On and Testing: Power up the system and verify module operation through system diagnostics or DCS interface.
6 Related or Series-Compatible Models
Model | Description | Input Type | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
IIAI01 | Analog Input Module | Analog | 24 VDC | 127 x 152 x 38 | 440 g |
IISAC01 | Isolated Analog Input Module | Analog | 24 VDC | 127 x 152 x 38 | 460 g |
IMASI23 | Analog Input Module with HART Support | Analog (HART) | 24 VDC | 130 x 160 x 40 | 470 g |
IIMCP01 | Multi-Channel Analog Input Module | Analog | 24 VDC | 135 x 155 x 40 | 490 g |
IMASO01 | Analog Output Module | Analog | 24 VDC | 127 x 152 x 38 | 450 g |
IIMAM01 | Multiplexer Analog Input Module | Analog | 24 VDC | 125 x 150 x 36 | 435 g |
8 Popular ABB Models
Model | Function | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|
IMDSO14 | Digital Output Module | 24 VDC | 127 x 152 x 38 | 420 g |
IMASI03 | Analog Input Module | 24 VDC | 127 x 152 x 38 | 430 g |
IMMFP12 | Multi-Function Processor | 5 VDC | 160 x 160 x 40 | 550 g |
IMMPI01 | Multipurpose Interface Module | 5 VDC | 127 x 152 x 38 | 460 g |
INNIS21 | Network Interface Module | 24 VDC | 127 x 152 x 38 | 440 g |
INICT13A | Communication Interface Module | 24 VDC | 130 x 160 x 40 | 470 g |
IMCPM02 | Central Processor Module | 5 VDC | 150 x 160 x 40 | 560 g |
IIMCP02 | Multi-Channel Processor | 5 VDC | 135 x 155 x 40 | 490 g |
Frequently Asked Questions (FAQ)
Q1: What is the primary function of the ABB Bailey IISACO1 module?
A1: The IISACO1 module is designed to acquire analog signals from field instruments and convert them into digital values for processing within the DCS.
Q2: Can the IISACO1 handle both voltage and current input types?
A2: Yes, it supports both 0-10 VDC and 4-20 mA input signal types, configurable based on system requirements.
Q3: Is the IISACO1 compatible with HART protocol signals?
A3: No, the IISACO1 does not support HART signals. For HART compatibility, consider using IMASI23.
Q4: How do I mount the IISACO1 module?
A4: It can be DIN rail mounted or fixed to a panel using the screw holes provided on the chassis.
Q5: What environmental conditions can the IISACO1 operate in?
A5: It is designed to operate between 0°C and 60°C with up to 95% non-condensing humidity.
Q6: How can I check if the IISACO1 is functioning properly after installation?
A6: After installation, use the system’s diagnostic tools or controller interface to verify signal acquisition and module status.
ABB Bailey IISACO1 Infi 90 Analog Control Station