Emerson KJ3001X1-BA1 12P0549X112 Product Overview
The Emerson KJ3001X1-BA1 12P0549X112 is a high-performance pressure transmitter designed for industrial applications. It offers precise measurement and reliable operation in harsh environments, making it suitable for industries such as oil & gas, chemical processing, and power generation.
Product Advantages
- High Accuracy: Delivers precise pressure measurements with minimal deviation.
- Robust Construction: Built to withstand extreme temperatures, vibrations, and corrosive environments.
- Easy Installation: Features a user-friendly design for quick setup and maintenance.
- Long-Term Stability: Ensures consistent performance over extended periods.
- Wide Compatibility: Works seamlessly with various industrial control systems.
Technical Parameters
Parameter | Value |
---|---|
Model Number | KJ3001X1-BA1 12P0549X112 |
Pressure Range | 0-1000 psi |
Accuracy | ±0.1% of full scale |
Output Signal | 4-20 mA, HART Protocol |
Power Supply | 10-30 VDC |
Operating Temperature | -40°C to 85°C |
Process Connection | 1/2″ NPT Female |
Housing Material | Stainless Steel (316L) |
Dimensions | 120 × 80 × 30 mm |
Weight | 0.2 kg |
Ingress Protection | IP67 |
Applications
- Oil & gas pipeline monitoring
- Chemical processing pressure control
- Power plant boiler systems
- Water and wastewater treatment
- HVAC system pressure regulation
Compatible Models for Integration
- Emerson KJ3001X1-BA2 (Higher pressure range variant)
- Emerson KJ4002X1-CA1 (Explosion-proof version)
- Emerson KJ2001X1-DA1 (Compact design for tight spaces)
Installation Instructions
- Mounting: Secure the transmitter using the provided brackets or direct process connection.
- Wiring: Connect the power supply (10-30 VDC) and output signal wires as per the wiring diagram.
- Calibration: Use a calibrated source to verify accuracy before commissioning.
- Sealing: Ensure all seals and gaskets are properly installed to prevent leaks.
- Testing: Perform a functional test under controlled conditions before full operation.
Recommended 6 Related/Series Models
Model | Pressure Range | Accuracy | Output | Voltage | Dimensions | Weight |
---|---|---|---|---|---|---|
KJ3001X1-BA2 | 0-2000 psi | ±0.1% | 4-20 mA/HART | 10-30 VDC | 4.5″ x 3.2″ x 2.1″ | 2.3 lbs |
KJ4002X1-CA1 | 0-5000 psi | ±0.15% | 4-20 mA/RS485 | 12-36 VDC | 5.1″ x 3.5″ x 2.4″ | 3.0 lbs |
KJ2001X1-DA1 | 0-500 psi | ±0.2% | 4-20 mA | 10-28 VDC | 3.9″ x 2.8″ x 1.8″ | 1.8 lbs |
KJ5001X1-EA1 | 0-10,000 psi | ±0.05% | 4-20 mA/HART | 15-30 VDC | 5.5″ x 4.0″ x 2.8″ | 3.5 lbs |
KJ3002X1-FA1 | 0-3000 psi | ±0.1% | 4-20 mA/Foundation Fieldbus | 10-30 VDC | 4.7″ x 3.3″ x 2.2″ | 2.5 lbs |
KJ1001X1-GA1 | 0-100 psi | ±0.25% | 4-20 mA | 9-26 VDC | 3.5″ x 2.5″ x 1.5″ | 1.2 lbs |
Top 8 Popular Emerson Models
Model | Type | Pressure Range | Accuracy | Voltage | Dimensions | Weight |
---|---|---|---|---|---|---|
Rosemount 3051S | Pressure Transmitter | 0-5000 psi | ±0.075% | 10-32 VDC | 5.3″ x 4.2″ x 2.6″ | 4.0 lbs |
Rosemount 2088 | Temperature Sensor | N/A | ±0.5°C | 12-24 VDC | 6.0″ x 1.8″ x 1.2″ | 1.5 lbs |
Micro Motion 2700 | Coriolis Flow Meter | 0-500 GPM | ±0.1% | 18-36 VDC | 8.7″ x 6.3″ x 4.9″ | 12.0 lbs |
Fisher D2T | Control Valve | 0-6000 psi | N/A | 24-120 VAC | 12″ x 8″ x 6″ | 22.0 lbs |
Rosemount 3144P | Temperature Transmitter | N/A | ±0.1°C | 12-42 VDC | 4.0″ x 3.0″ x 1.5″ | 1.0 lb |
Daniel 3410 | Ultrasonic Flow Meter | 0-30 m/s | ±0.5% | 100-240 VAC | 10″ x 8″ x 5″ | 15.0 lbs |
Bettis RTS | Actuator | N/A | N/A | 24-480 VAC | 15″ x 10″ x 8″ | 30.0 lbs |
Roxar 2600 | Multiphase Meter | 0-5000 psi | ±1.0% | 24 VDC | 20″ x 15″ x 12″ | 50.0 lbs |
FAQ (Q&A Format)
Q1: What is the operating temperature range of the KJ3001X1-BA1?
A1: The transmitter operates reliably between -40°C and 85°C.
Q2: Can this transmitter be used in explosive environments?
A2: No, the KJ3001X1-BA1 is not explosion-proof. For hazardous areas, consider the KJ4002X1-CA1.
Q3: What is the warranty period for this product?
A3: Emerson typically offers a 5-year warranty for this model, subject to terms and conditions.
Q4: Is calibration required before installation?
A4: Yes, it is recommended to calibrate the device using a certified pressure source.
Q5: What is the expected lifespan of this transmitter?
A5: With proper maintenance, the transmitter can last over 10 years in standard industrial conditions.
Q6: Can the output signal be customized?
A6: The default output is 4-20 mA with HART, but other protocols (e.g., RS485) may require a different model.
Emerson KJ3001X1-BA1 12P0549X112 A Isolated Discrete Input Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
12P0549X112, A Isolated Discrete Input Module, Emerson, Emerson KJ3001X1-BA1 12P0549X112, KJ3001X1-BA1