HIMA F2 DO 16 02 Product Documentation
Product Introduction
The HIMA F2 DO 16 02 is a high-performance digital output module designed for safety-critical applications in industrial automation and process control. It is part of HIMA’s renowned F2 series, known for its reliability and robust design. This module provides 16 digital outputs with high switching capacity, making it suitable for demanding environments such as oil & gas, chemical plants, and power generation.
The F2 DO 16 02 ensures fail-safe operation and complies with international safety standards, including SIL 3 (Safety Integrity Level) as per IEC 61508. Its rugged construction allows for deployment in harsh conditions, ensuring long-term stability and minimal maintenance requirements.
Product Advantages
- High Reliability: Designed for mission-critical applications with a focus on fail-safe operation.
- Robust Construction: Suitable for harsh industrial environments with wide temperature and humidity ranges.
- Compliance with Safety Standards: Meets SIL 3 requirements (IEC 61508) for safety applications.
- Easy Integration: Compatible with HIMA’s safety systems and third-party PLCs via standard communication protocols.
- High Switching Capacity: Supports high-current loads, reducing the need for additional relays.
- Diagnostic Features: Built-in diagnostics for quick fault detection and troubleshooting.
Technical Specifications
Parameter | Value |
---|---|
Type | Digital Output Module |
Number of Outputs | 16 |
Output Type | Relay / Transistor (Specify) |
Switching Voltage | 24V DC (Range: 18-30V DC) |
Max. Current per Channel | 2A (for relay type) |
Total Max. Current | 8A (for all channels combined) |
Dimensions | 255 x 114 x 113 mm |
Weight | 2 kg |
Operating Temperature | -20°C to +60°C |
Protection Rating | IP20 (Higher ratings available) |
Certifications | SIL 3, CE, UL, ATEX (Optional) |
Applications
- Process Industries: Emergency shutdown systems (ESD) in oil refineries and chemical plants.
- Power Generation: Turbine control and safety interlocks.
- Manufacturing: Machine safety controls in automotive and heavy industries.
- Rail & Transportation: Signaling and safety-critical control systems.
- Marine & Offshore: Fire and gas detection systems.
Compatible & Recommended Accessories
- Backplane Module: HIMA F2 BP 01 (for mounting in rack systems).
- Power Supply Unit: HIMA F2 PS 24V/5A (dedicated power module).
- Communication Module: HIMA F2 COM 01 (for Profibus/Profinet integration).
- Terminal Blocks: HIMA F2 TB 16 (for secure wiring connections).
Installation Instructions
- Mounting: Secure the module on a DIN rail or within a HIMA F2 rack using the provided clips.
- Wiring: Connect the output channels to the load devices using shielded cables (max. 2.5mm² cross-section).
- Power Connection: Supply 24V DC to the designated terminals, ensuring correct polarity.
- Grounding: Properly ground the module to avoid electrical noise interference.
- Configuration: Use HIMA’s safety software (e.g., Safety Manager) to configure the outputs and diagnostics.
- Testing: Perform a functional test before commissioning to verify all outputs operate correctly.
6 Related Models in the F2 Series
Model | Type | Channels | Voltage | Current | Dimensions | Weight |
---|---|---|---|---|---|---|
F2 DI 16 01 | Digital Input | 16 | 24V DC | 10mA/ch | 100x120x75mm | 400g |
F2 AI 8 01 | Analog Input | 8 | 0-10V/4-20mA | 2mA/ch | 100x120x75mm | 420g |
F2 DO 8 02 | Digital Output | 8 | 24V DC | 2A/ch | 80x120x75mm | 350g |
F2 RTD 4 01 | RTD Input | 4 | 24V DC | 5mA/ch | 80x120x75mm | 380g |
F2 COM 01 | Communication | Profibus/Profinet | 24V DC | 500mA | 100x120x75mm | 450g |
F2 PS 24V | Power Supply | – | 24V DC/5A | 5A total | 120x150x80mm | 600g |
8 Popular HIMA Models (Other Series)
Model | Type | Key Parameters | Dimensions | Weight |
---|---|---|---|---|
H51q CPU | Safety Controller | SIL 3, Dual-core, 2MB Memory | 200x150x90mm | 1.2kg |
HIMatrix | Modular System | Configurable I/O, SIL 3 Certified | Varies | Varies |
H41q ETH | Ethernet Module | 100Mbps, Redundant Ports | 100x120x75mm | 500g |
HIMax | High-availability PLC | SIL 3, Hot-swappable I/O | 300x200x120mm | 2.5kg |
H37q DI | Digital Input | 32 ch, 24V DC, 5mA/ch | 100x120x75mm | 450g |
H29q AI | Analog Input | 16 ch, ±10V/4-20mA, 0.1% Accuracy | 120x150x80mm | 550g |
H10q PS | Power Supply | 24V DC/10A, Redundant Input | 150x200x90mm | 1.8kg |
H23q COM | Communication | Profinet, RS485, Dual-channel | 100x120x75mm | 480g |
FAQ (Frequently Asked Questions)
Q1: What is the maximum load current per channel for the F2 DO 16 02?
A1: Each channel supports up to 2A for relay-type outputs. The total combined current for all channels must not exceed 8A.
Q2: Can this module be used in explosive environments?
A2: Yes, but only with the ATEX-certified variant (order suffix “-EX”). Standard version is rated for IP20.
Q3: Is hot-swapping possible with the F2 DO 16 02?
A3: No, the module must be powered down before installation or removal to prevent damage.
Q4: What software is needed for configuration?
A4: HIMA’s Safety Manager or equivalent engineering tool is required for parameterization.
Q5: Are there redundant output options?
A5: Redundancy must be implemented at the system level using dual modules and voting logic.
Q6: What is the typical lifespan of the relay contacts?
A6: Under normal conditions (2A resistive load), the relays last for ≥100,000 cycles.