Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Description: HIMA F2108
The HIMA F2108 is a high-performance digital output module designed for use in HIMA’s renowned safety-related programmable electronic systems. It plays a crucial role in processing and controlling safety-critical outputs in industrial automation environments. Specifically engineered to ensure secure shutdown, control, and emergency operations, the F2108 module features robust architecture and enhanced reliability, making it suitable for applications that demand the highest safety integrity levels (SIL).
This module operates with 8 digital outputs and is typically used to drive actuators or interface with field devices. It offers advanced diagnostic functions to monitor system health, provides galvanic isolation between field and system circuits, and meets international safety and electromagnetic compatibility standards.
Product Advantages
-
High Safety Compliance: Certified for use in SIL3 applications according to IEC 61508 standards, ensuring the highest safety levels.
-
Robust Output Channels: Offers 8 secure digital outputs for precise and fail-safe operations.
-
Advanced Diagnostics: Built-in diagnostics allow early detection of failures and enhanced system availability.
-
Electromagnetic Compatibility: Strong EMC protection enables stable operation in harsh industrial environments.
-
Redundancy Support: Compatible with redundant configurations, minimizing downtime and enhancing reliability.
-
Compact Design: Space-saving construction suitable for high-density cabinet installations.
-
Long Service Life: Engineered for durability and low maintenance over extended operational periods.
Technical Specifications
Parameter | Description |
---|---|
Model | HIMA F2108 |
Function | Digital Output Module |
Number of Outputs | 8 |
Output Type | Digital (24 V DC) |
Operating Voltage | 24 V DC (nominal) |
Output Current (per channel) | Up to 0.5 A |
Power Consumption | Approx. 2.5 W |
Isolation | Galvanic isolation between field/system |
Diagnostic Functions | Channel diagnostics, wire-break detection |
Protection Class | IP20 |
Safety Integrity Level | SIL3 (IEC 61508) |
Operating Temperature | 0°C to +60°C |
Storage Temperature | -40°C to +85°C |
Humidity | 5–95% RH, non-condensing |
Dimensions | 160 x 120 mm |
Weight | 0.231kg |
Mounting | DIN Rail Mounting |
Housing Material | High-quality industrial-grade plastic |
Applications
The HIMA F2108 module is ideal for applications that require fail-safe control and output in mission-critical environments. Some common areas of application include:
-
Petrochemical plants
-
Oil and gas platforms
-
Nuclear and thermal power plants
-
Railway safety systems
-
Industrial automation lines
-
Emergency shutdown systems (ESD)
-
Burner management systems (BMS)
It is extensively used in systems where safety, reliability, and availability are paramount.
Compatible Models (System Use)
The F2108 module is designed for seamless integration with the following HIMA safety controller platforms and modules:
-
HIMatrix F-series
-
HIQuad X
-
F8627X CPU Module
-
F8650X CPU Module
-
F7133 Power Supply Module
-
F7553 I/O Bus Coupler
-
F8621A Communication Processor
Installation Guide
-
Pre-Installation Checks
-
Ensure the system is powered off.
-
Verify compatibility with the safety controller system.
-
Check for visible damage or deformities on the module.
-
-
Mounting the Module
-
Snap the F2108 module onto a standard DIN rail.
-
Ensure proper grounding of the control cabinet to avoid electrostatic discharge.
-
-
Wiring
-
Connect the field devices to the output terminals.
-
Maintain correct polarity for DC connections.
-
Use shielded cables in environments with high EMI.
-
-
System Integration
-
Connect the module to the appropriate CPU and communication modules via the backplane.
-
Configure output channels using the system configuration tool (e.g., SILworX).
-
-
Powering and Testing
-
Apply power and check the module LED indicators.
-
Perform system diagnostics to verify communication and channel status.
-
Conduct a functional test to confirm output signals.
-
-
Documentation
-
Record installation details, wiring diagrams, and test results in the system logbook.
-
Related Models (Same Series or Compatible)
Here are six related or similar HIMA modules:
-
HIMA F2201 – Digital Input Module, 16 channels
-
HIMA F3108 – Analog Output Module
-
HIMA F7133 – Power Supply Module
-
HIMA F8650X – Advanced CPU Module for High-Availability Systems
-
HIMA F8627X – Compact Safety Controller
-
HIMA F6705 – Communication Interface Module
Popular HIMA Models with Parameters
Model | Description | Channels | Voltage | Dimensions (mm) | Weight | SIL Level |
---|---|---|---|---|---|---|
F2108 | Digital Output Module | 8 | 24 V DC | 160×35×120 | 320 g | SIL3 |
F2201 | Digital Input Module | 16 | 24 V DC | 160×35×120 | 310 g | SIL3 |
F3108 | Analog Output Module | 8 | 0–20 mA | 160×35×120 | 330 g | SIL3 |
F8627X | CPU Module | — | 24 V DC | 160×60×120 | 500 g | SIL3 |
F8650X | Advanced CPU Module | — | 24 V DC | 160×60×120 | 550 g | SIL3 |
F6705 | Communication Interface | — | 24 V DC | 160×35×120 | 290 g | SIL3 |
F7133 | Power Supply Module | — | 24–60 V DC | 160×35×120 | 370 g | — |
F7553 | I/O Bus Coupler | — | 24 V DC | 160×35×120 | 300 g | SIL3 |
Frequently Asked Questions (FAQ)
Q1: What is the primary function of the HIMA F2108?
A1: The HIMA F2108 functions as a digital output module, used to control and switch external actuators in a safety-critical automation system.
Q2: Can the F2108 be used in SIL3 certified systems?
A2: Yes, the F2108 is certified for use in SIL3 systems according to IEC 61508 standards, making it suitable for high-integrity safety applications.
Q3: How many output channels does the F2108 support?
A3: It supports 8 independent digital output channels with diagnostic capabilities.
Q4: What type of devices can be controlled using the F2108?
A4: The F2108 can control solenoid valves, relays, lamps, contactors, and other field devices requiring digital switching.
Q5: Is the F2108 module hot-swappable?
A5: No, the F2108 should not be inserted or removed while the system is powered. Always power down before handling the module.
Q6: What software is used to configure the F2108?
A6: The module can be configured and diagnosed using HIMA’s SILworX software, which supports project design, safety logic, and testing.