Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
HIMA F2302 Safety Relay Module
Product Introduction
The HIMA F2302 is a dual-channel safety relay module specifically designed for high-integrity process automation systems. Manufactured by HIMA, a global leader in safety-related automation solutions, this module serves as a critical component in safety instrumented systems (SIS). The F2302 is engineered to deliver reliable and fail-safe switching operations, ensuring the protection of personnel, equipment, and the environment in hazardous industrial applications.
It operates by processing binary signals from field devices and actuating safety outputs in compliance with international safety standards such as IEC 61508 (SIL 3). With its robust design, the F2302 is ideally suited for industries such as oil & gas, chemical, petrochemical, power generation, and more.
The HIMA F2302 integrates seamlessly into HIMA’s advanced safety systems, providing exceptional diagnostic coverage and enhanced operational reliability. Its compact form factor also enables flexible installation in space-constrained control panels.
Product Advantages
-
Certified SIL 3 Safety Compliance
Fully compliant with IEC 61508 for Safety Integrity Level 3 applications, ensuring the highest standards of safety performance. -
Dual-Channel Redundancy
Features independent dual-channel architecture, enhancing reliability and fault tolerance. -
High Diagnostic Coverage
Advanced diagnostic features allow early detection of faults, reducing downtime and maintenance efforts. -
Robust Build Quality
Designed for harsh industrial environments, with resistance to vibration, shock, and extreme temperatures. -
Easy Integration
Seamlessly integrates with HIMA safety systems and supports diverse field devices. -
Compact Design
Space-saving module suitable for installations with limited panel space. -
Wide Operating Range
Supports a wide voltage range and can operate under varied environmental conditions.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | HIMA F2302 |
Function | Dual-channel safety relay module |
Safety Integrity Level (SIL) | SIL 3 (IEC 61508) |
Input Voltage | 24 V DC (nominal) |
Voltage Range | 18 V DC to 30 V DC |
Power Consumption | Approx. 2.5 W |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +85°C |
Dimensions | 150 x 120 mm |
Weight | 0.5 kg |
Output Type | Relay output, NO (Normally Open) contacts |
Contact Rating | 250 V AC / 6 A or 24 V DC / 6 A |
Channel Configuration | Dual-channel independent |
Installation | DIN rail mounting |
Diagnostics | Integrated self-diagnostics and fault reporting |
Vibration Resistance | 10 Hz to 150 Hz, 2 g |
Shock Resistance | 15 g / 11 ms |
Protection Class | IP20 |
Approvals | CE, TÜV, ATEX, IECEx |
Applications
-
Oil and Gas Industry
Emergency shutdown systems, fire and gas detection, blowout preventers. -
Chemical and Petrochemical Plants
Process safety controls, overpressure protection systems. -
Power Generation
Turbine control systems, generator protection. -
Pharmaceutical Manufacturing
Ensuring safe operation of critical production processes. -
Water Treatment Facilities
Safety interlocking systems for pumps and chemical dosing units. -
Steel and Metal Processing Plants
High-temperature area safety interlocks and emergency stops.
Compatible Models
-
HIMA F35 Series Controllers
-
HIMA HIMax Series
-
HIMA H41/H51q Systems
-
HIMA F7133 Relay Modules
-
HIMA F8650E CPU Modules
-
HIMA X20 Safety System
Installation Instructions
-
Preparation
Ensure the power supply is turned off before installation. Verify the compatibility of the module with your system. -
Mounting
Install the F2302 onto a standard DIN rail inside the control panel. Secure the module properly to prevent vibration-induced loosening. -
Wiring Connections
Connect the input and output wiring as per the wiring diagram provided in the HIMA installation manual. Use ferrules to ensure secure connections. -
System Integration
Integrate the module into the safety system configuration using HIMA’s engineering tools (e.g., SILworX). -
Commissioning
Power up the system and perform functional tests. Verify all diagnostics indicators to ensure proper operation. -
Maintenance
Periodically inspect wiring connections and clean the module using non-static tools. Utilize built-in diagnostics for regular system health checks.
Related Models (Same Series or Similar Functionality)
Model Number | Function | Voltage Range | Dimensions (mm) | Weight |
---|---|---|---|---|
HIMA F2301 | Safety relay module, single channel | 18-30 V DC | 48 x 128 x 118 | 215 g |
HIMA F7133 | Relay module, output expansion | 18-30 V DC | 48 x 128 x 118 | 225 g |
HIMA F3330 | Digital input module, safe inputs | 24 V DC | 48 x 128 x 118 | 210 g |
HIMA F3221 | Analog input module, high accuracy | 18-30 V DC | 48 x 128 x 118 | 220 g |
HIMA F8650E | CPU module, high-performance | 18-30 V DC | 160 x 128 x 118 | 750 g |
HIMA F7553 | Power supply module for safety systems | 24 V DC | 160 x 128 x 118 | 720 g |
Popular HIMA Models (Recommended with Specifications)
Model Number | Function | Voltage Range | Dimensions (mm) | Weight |
---|---|---|---|---|
HIMA HIMax | High-performance safety controller | 24 V DC | 482.6 x 177 x 320 | 15 kg |
HIMA F7133 | Relay module, output expansion | 18-30 V DC | 48 x 128 x 118 | 225 g |
HIMA F8627X | CPU module for HIMax | 24 V DC | 175 x 150 x 160 | 1.2 kg |
HIMA F8650E | CPU module, high-performance | 18-30 V DC | 160 x 128 x 118 | 750 g |
HIMA F6208 | Analog output module | 24 V DC | 48 x 128 x 118 | 220 g |
HIMA F3330 | Digital input module | 24 V DC | 48 x 128 x 118 | 210 g |
HIMA H51q | High-reliability controller | 24 V DC | 482.6 x 177 x 320 | 14.5 kg |
HIMA X20 | Compact safety control system | 24 V DC | 100 x 200 x 150 | 2.8 kg |
FAQ (Frequently Asked Questions)
Q1: What is the main function of the HIMA F2302?
A1: The HIMA F2302 serves as a dual-channel safety relay module, providing reliable signal processing and safe switching operations in critical safety applications.
Q2: Can the HIMA F2302 operate in high-temperature environments?
A2: Yes, the F2302 is designed to operate reliably in temperatures ranging from -20°C to +60°C, making it suitable for harsh industrial environments.
Q3: What safety standards does the F2302 comply with?
A3: The F2302 complies with IEC 61508 and is certified for Safety Integrity Level 3 (SIL 3), ensuring the highest level of operational safety.
Q4: How is the F2302 installed?
A4: The module is installed on a standard DIN rail within the control panel, with all connections made following the wiring diagrams and installation manual provided by HIMA.
Q5: Does the F2302 have diagnostic capabilities?
A5: Yes, the module features advanced self-diagnostics and fault reporting to ensure early detection of issues and to enhance system reliability.
Q6: Is the F2302 compatible with older HIMA systems?
A6: Absolutely. The F2302 is compatible with multiple HIMA systems, including the H41/H51q, HIMax, and F35 series, making it versatile for new and legacy installations.
HIMA F2302 PLCs/Machine Control
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |