HIMA F2304 Product Overview
The HIMA F2304 is a high-performance, safety-related I/O module engineered to meet the rigorous demands of industrial safety systems. Designed and manufactured by HIMA, a globally recognized leader in functional safety technology, the F2304 module plays a critical role in emergency shutdown systems (ESD), fire and gas detection systems, and other safety instrumented systems (SIS).
The F2304 integrates seamlessly into HIMA’s modular safety platforms, providing reliable signal processing for critical safety applications. Built with precision German engineering, the module ensures high availability, outstanding diagnostic coverage, and real-time response capabilities to protect personnel, equipment, and the environment.
Its robust design, certified safety compliance, and exceptional performance make it a preferred choice for industries such as oil & gas, chemical processing, power generation, and industrial automation worldwide.
Product Advantages
-
Certified Safety Integrity
Complies with SIL 3 according to IEC 61508 and related standards, ensuring highest operational safety. -
High Diagnostic Coverage
Advanced diagnostics enable early fault detection, predictive maintenance, and minimized downtime. -
Robust Design
Industrial-grade construction with high vibration resistance and wide temperature tolerance. -
Modular and Scalable
Easy to integrate into existing HIMA systems and scalable for future expansion. -
Real-Time Performance
Fast response time supports time-critical safety applications. -
Global Support and Longevity
Backed by HIMA’s global service network, long product lifecycle, and comprehensive support.
Technical Specifications
Parameter | Description |
---|---|
Model | HIMA F2304 |
Function | Digital Output Module |
Safety Integrity Level (SIL) | SIL 3, IEC 61508 Certified |
Number of Channels | 16 Digital Outputs |
Operating Voltage | 24 V DC (nominal) |
Voltage Range | 18 V DC to 30 V DC |
Output Current per Channel | Max. 2 A |
Module Dimensions | 150 x 120 mm |
Weight | 0.5 kg |
Power Consumption | Approx. 5 W |
Operating Temperature Range | -20°C to +60°C |
Storage Temperature Range | -40°C to +85°C |
Humidity | 5% to 95% non-condensing |
Vibration Resistance | Up to 2 g (10–150 Hz) |
EMC Compliance | EN 61000-6-2, EN 61000-6-4 |
Mounting Type | DIN Rail Mounting |
Connection Type | Plug-in screw terminals |
Diagnostics | Integrated diagnostics with fault indication |
Certification | ATEX, IECEx, SIL 3, CE |
Applications
-
Emergency Shutdown Systems (ESD)
Vital component in emergency shutdown architectures, ensuring safe isolation of critical processes. -
Fire & Gas Detection Systems (F&G)
Processes output signals to actuators during fire or gas leak events. -
Chemical Processing Plants
Provides safe control of hazardous process parameters. -
Oil & Gas Platforms
Supports offshore and onshore safety functions under harsh environmental conditions. -
Power Generation Facilities
Ensures safe operation and shutdown of turbines and associated systems. -
Industrial Automation Safety
Ideal for use in highly automated safety-critical environments.
Compatible Models for System Integration
-
HIMA CPU F8650E
-
HIMA F7133
-
HIMA F3221
-
HIMA F7130
-
HIMA F7553
-
HIMA F8627X
These models are commonly used in combination with the F2304 to build a complete safety solution, ensuring reliable communication and efficient process control.
Installation Instructions
-
Preparation
Ensure the control panel is de-energized before installation. Verify environmental conditions align with the specified operational range. -
Mounting
Mount the F2304 securely on a DIN rail within the system enclosure. Ensure proper spacing for ventilation and heat dissipation. -
Wiring
Connect power supply cables to the designated terminals. Wire the field devices to the output terminals following the wiring diagram. -
Configuration
Use the HIMA engineering tool to configure module parameters and channel assignments. -
Verification
Perform continuity and insulation resistance tests. Validate wiring against the system documentation. -
Testing
Conduct functional tests to ensure correct operation. Check diagnostic indicators for module health status. -
Commissioning
Once testing is complete, commission the system and monitor initial operation to verify stable performance.
Related Models (Same Series or Application)
Model | Description | Channels | Voltage | Dimensions (W x H x D) | Weight |
---|---|---|---|---|---|
HIMA F3330 | Digital Input Module | 16 | 24 V DC | 40 x 160 x 130 mm | 460 g |
HIMA F3221 | Analog Input Module | 8 | 24 V DC | 40 x 160 x 130 mm | 470 g |
HIMA F7133 | Relay Output Module | 8 | 24 V DC | 40 x 160 x 130 mm | 480 g |
HIMA F7553 | Power Supply Module | – | 24 V DC | 40 x 160 x 130 mm | 500 g |
HIMA F8627X | CPU Module for Safety Applications | – | 24 V DC | 40 x 160 x 130 mm | 510 g |
HIMA F7130 | Analog Output Module | 8 | 24 V DC | 40 x 160 x 130 mm | 470 g |
Popular HIMA Models
Model | Description | Channels | Voltage | Dimensions (W x H x D) | Weight |
---|---|---|---|---|---|
HIMA F8650E | High-Performance CPU Module | – | 24 V DC | 80 x 160 x 130 mm | 700 g |
HIMA F7133 | Relay Output Module | 8 | 24 V DC | 40 x 160 x 130 mm | 480 g |
HIMA F3330 | Digital Input Module | 16 | 24 V DC | 40 x 160 x 130 mm | 460 g |
HIMA F3221 | Analog Input Module | 8 | 24 V DC | 40 x 160 x 130 mm | 470 g |
HIMA F8652X | Redundant CPU Module | – | 24 V DC | 80 x 160 x 130 mm | 720 g |
HIMA F7553 | Power Supply Module | – | 24 V DC | 40 x 160 x 130 mm | 500 g |
HIMA F7130 | Analog Output Module | 8 | 24 V DC | 40 x 160 x 130 mm | 470 g |
HIMA F8627X | CPU Module for Safety Applications | – | 24 V DC | 40 x 160 x 130 mm | 510 g |
FAQs
Q1: What safety certifications does the HIMA F2304 hold?
A1: The F2304 is certified to SIL 3 according to IEC 61508 standards and complies with ATEX, IECEx, and CE requirements.
Q2: Can the F2304 operate in extreme temperatures?
A2: Yes, the module operates reliably in a temperature range of -20°C to +60°C and can be stored in temperatures from -40°C to +85°C.
Q3: Is the F2304 module suitable for use in offshore environments?
A3: Absolutely. The robust design and high vibration resistance make it ideal for harsh environments like offshore oil and gas platforms.
Q4: How is the F2304 module installed?
A4: Installation involves DIN rail mounting, proper wiring of power and field connections, configuration through HIMA tools, and system testing before commissioning.
Q5: Does the F2304 support diagnostic features?
A5: Yes, it includes integrated diagnostics for real-time monitoring and fault indication, enhancing system reliability and maintenance efficiency.
Q6: Can I integrate the F2304 with legacy HIMA systems?
A6: Yes, the F2304 is fully compatible with HIMA’s modular safety systems and can be integrated with existing architectures.