HIMA F3 AIO 8/4 01 Product Documentation
Product Introduction
The HIMA F3 AIO 8/4 01 is a high-performance safety controller designed for industrial automation and process safety applications. It combines robust hardware with advanced safety logic solvers to ensure reliable operation in critical environments. This all-in-one (AIO) unit integrates multiple safety functions, including emergency shutdown (ESD), fire and gas detection (F&G), and burner management systems (BMS).
The F3 AIO 8/4 01 is part of HIMA’s F3 series, known for its modularity, scalability, and compliance with international safety standards such as IEC 61508 and IEC 61511. It is widely used in oil & gas, chemical, power generation, and other high-risk industries.
Product Advantages
- High Reliability – Built with fail-safe architecture and redundant components to minimize downtime.
- Modular Design – Allows for easy expansion and customization based on application requirements.
- Certified Safety – Complies with SIL 3 (Safety Integrity Level 3) standards.
- User-Friendly Configuration – Supports HIMA’s proprietary safety software for seamless programming and diagnostics.
- Robust Construction – Designed to withstand harsh industrial environments (wide temperature range, vibration resistance).
- Fast Response Time – Ensures immediate action in critical safety scenarios.
Technical Parameters
Parameter | Specification |
---|---|
Dimensions | 207 x 114 x 97 mm |
Weight | 1 kg |
Input Voltage | 24 V DC (18–32 V range) |
Power Consumption | 15 W (typical) |
Operating Temp. | -40°C to +70°C |
Safety Certification | SIL 3 (IEC 61508), TÜV certified |
Number of Channels | 8 digital inputs / 4 digital outputs |
Communication | Ethernet, RS-485, PROFIBUS DP (optional) |
Response Time | < 10 ms |
Applications
- Oil & Gas: Emergency shutdown systems (ESD), pipeline monitoring.
- Chemical Plants: Process safety management, leak detection.
- Power Generation: Turbine protection, boiler safety.
- Manufacturing: Machine safety interlocks, robotic cell protection.
- Transportation: Rail signaling, tunnel safety systems.
Compatible Models
The HIMA F3 AIO 8/4 01 can be paired with:
- HIMA F3 DI 16/8 (16-input/8-output module)
- HIMA F3 AI 8 (8-channel analog input module)
- HIMA F3 COM (communication gateway for PROFIBUS/Modbus)
- HIMA F3 PS (redundant power supply unit)
Installation Instructions
- Mounting: Secure the unit on a DIN rail or flat surface using provided screws.
- Wiring: Connect power supply (24 V DC) and I/O signals as per the terminal diagram.
- Grounding: Ensure proper grounding to avoid electrical interference.
- Configuration: Use HIMA Safety Software to program logic and test functionality.
- Testing: Perform a full diagnostic test before commissioning.
Recommended Related Models (F3 Series)
Model | Dimensions | Weight | Voltage | Channels | Key Feature |
---|---|---|---|---|---|
F3 AIO 16/8 01 | 200×150×80 mm | 2.0 kg | 24 V DC | 16 IN / 8 OUT | High-density I/O |
F3 DI 32/16 | 250×180×90 mm | 2.5 kg | 24 V DC | 32 IN / 16 OUT | Large-scale digital control |
F3 AI 16 | 200×150×80 mm | 1.9 kg | 24 V DC | 16 analog inputs | Precision signal processing |
F3 COM PROFIBUS | 150×100×60 mm | 1.2 kg | 24 V DC | N/A | PROFIBUS-DP integration |
F3 PS Redundant | 120×80×60 mm | 0.8 kg | 24 V DC | Dual power inputs | Fail-safe power supply |
F3 CPU SIL 4 | 200×150×80 mm | 2.2 kg | 24 V DC | Configurable | SIL 4 compliance |
Popular HIMA Models (Other Series)
Model | Dimensions | Weight | Voltage | Channels | Key Feature |
---|---|---|---|---|---|
HIMA H51q | 300×200×100 mm | 3.5 kg | 24 V DC | 32 IN / 16 OUT | Modular SIL 3 system |
HIMA HIMatrix | 400×250×120 mm | 5.0 kg | 24 V DC | Up to 512 I/O | Large-scale safety solutions |
HIMA HIQuad X | 200×150×80 mm | 2.0 kg | 24 V DC | 16 IN / 8 OUT | Compact quad-redundant design |
HIMA H41q | 250×180×90 mm | 2.8 kg | 24 V DC | 24 IN / 12 OUT | High availability system |
HIMA H20 | 150×100×60 mm | 1.0 kg | 24 V DC | 8 IN / 4 OUT | Cost-effective SIL 2 solution |
HIMA H10 | 120×80×50 mm | 0.7 kg | 24 V DC | 4 IN / 2 OUT | Basic safety controller |
HIMA H30 | 180×120×70 mm | 1.5 kg | 24 V DC | 12 IN / 6 OUT | Mid-range SIL 2/3 controller |
HIMA HIPro | 350×220×110 mm | 4.5 kg | 24 V DC | 64 IN / 32 OUT | Industrial process safety |
FAQ (Q&A)
Q1: What is the maximum operating temperature for the F3 AIO 8/4 01?
A1: The unit operates reliably between -40°C and +70°C.
Q2: Can I expand the I/O capacity of the F3 AIO 8/4 01?
A2: Yes, additional I/O modules (e.g., F3 DI 16/8) can be connected via the backplane.
Q3: Is the F3 AIO 8/4 01 suitable for SIL 4 applications?
A3: No, it is certified for SIL 3. For SIL 4, consider the F3 CPU SIL 4 model.
Q4: What communication protocols are supported?
A4: Ethernet, RS-485, and optional PROFIBUS-DP.
Q5: How do I troubleshoot a fault in the system?
A5: Use HIMA Safety Software for diagnostics, or check LED indicators on the front panel.
Q6: Is redundancy supported for critical applications?
A6: Yes, redundant configurations can be achieved using the F3 PS Redundant power supply and dual CPU setups.
HIMA F3 AIO 8/4 01 Remote I/O Modules
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |