Product Introduction: HIMA F30 03
The HIMA F30 03 is a high-performance fail-safe digital input module designed for use in HIMA’s renowned HIMax and HIQuad safety systems. Known for their rigorous safety integrity and reliability, HIMA modules like the F30 03 are widely deployed in safety instrumented systems (SIS) across various critical industries such as oil & gas, petrochemicals, power generation, and more.
The F30 03 module features robust diagnostic functions and is engineered to comply with SIL 3 requirements under IEC 61508. It enables real-time monitoring and safe status feedback for digital input signals, ensuring immediate reaction to process changes or failures. Its hot-swappable design and compatibility with HIMA’s safety platforms make it an ideal solution for critical control and automation environments where system availability and functional safety are paramount.
Product Advantages
-
SIL 3 Certified: Meets stringent IEC 61508 safety standards, making it suitable for high-integrity applications.
-
Comprehensive Diagnostics: Integrated fault detection and reporting increase system reliability and reduce downtime.
-
Hot-Swappable Design: Enables module replacement during operation without interrupting the system.
-
Modular Integration: Seamlessly integrates with HIMax and HIQuad systems for scalable, flexible configurations.
-
High Electromagnetic Compatibility: Ensures reliable performance in electrically noisy industrial environments.
-
Extended Lifecycle Support: Backed by HIMA’s long-term availability and lifecycle services, reducing total cost of ownership.
Technical Specifications
Parameter | Specification |
---|---|
Product Model | HIMA F30 03 |
Input Channels | 16 digital inputs |
Input Voltage Range | 18–30 V DC |
Nominal Voltage | 24 V DC |
Input Current | Typically 4 mA at 24 V DC |
Diagnostic Functions | Short circuit, wire break, cross fault detection |
Safety Integrity Level | SIL 3 (IEC 61508) |
Mounting Type | Backplane rack installation |
Operating Temperature Range | -20°C to +60°C |
Storage Temperature Range | -40°C to +85°C |
Dimensions | 257 x 114 x 66 mm |
Weight | 1.2 kg |
Power Consumption | < 3 W |
Isolation | Galvanic isolation per channel |
System Compatibility | HIMax, HIQuad systems |
Applications
The HIMA F30 03 module is specifically designed for use in safety-critical systems that require real-time processing of digital input signals. It is ideal for:
-
Emergency Shutdown Systems (ESD)
-
Fire and Gas Detection Systems (F&G)
-
Burner Management Systems (BMS)
-
Turbo Machinery Control (TMC)
-
Subsea Safety Systems
-
Railway Automation and Signaling
-
Chemical and Petrochemical Processing Units
Compatible Models
The HIMA F30 03 is typically used in conjunction with the following HIMA modules:
-
F20 01 – Digital Output Module
-
F60 16 – Analog Input Module
-
F35 01 – Communication Interface Module
-
F3221 – Relay Output Module
-
F7133 – CPU Processor Module
-
F8621A – Power Supply Module
These modules together form an integrated safety control system tailored to specific industry requirements.
Installation Instructions
-
Power Down (if not hot-swapping): If not replacing a module during live operation, ensure system power is turned off before installation.
-
Slot Verification: Confirm the correct slot location on the backplane. The F30 03 should be installed only in slots approved for digital input modules.
-
Module Insertion: Align the module’s connectors with the backplane and press firmly until it clicks into place.
-
Wiring Connections: Connect the field wiring to the terminal blocks. Ensure polarity and terminal numbers match the wiring diagram.
-
System Configuration: Use HIMA’s programming tools (e.g., ELOP II, SILworX) to configure the module and assign input addresses.
-
Diagnostics Check: After powering on, verify module operation through the diagnostic LEDs and the system software interface.
-
Functional Testing: Run a system-wide test to ensure the new module is correctly integrated and functional.
6 Related Models
Model | Description | Input/Output | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
F20 01 | Digital Output Module | 16 DO | 24 V DC | 30 x 100 x 120 | 180 g |
F60 16 | Analog Input Module | 8 AI | 0-10 V / 4-20 mA | 30 x 100 x 120 | 190 g |
F3221 | Relay Output Module | 4 Relay DO | 24 V DC | 40 x 100 x 120 | 200 g |
F8621A | Power Supply Module | – | 24 V DC IN | 50 x 120 x 130 | 400 g |
F35 01 | Communication Interface Module | – | – | 30 x 100 x 120 | 170 g |
F7133 | CPU Processor Module | – | 5 V DC | 40 x 100 x 120 | 220 g |
8 Popular HIMA Models
Model | Function | I/O Type | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
F30 03 | Digital Input Module | 16 DI | 24 V DC | 30 x 100 x 120 | 180 g |
F20 01 | Digital Output Module | 16 DO | 24 V DC | 30 x 100 x 120 | 180 g |
F60 16 | Analog Input Module | 8 AI | 0–10 V / 4–20 mA | 30 x 100 x 120 | 190 g |
F8650X | CPU Module with Ethernet | – | 5 V DC | 40 x 100 x 130 | 230 g |
F7126 | Redundant Power Supply Controller | – | 24 V DC | 50 x 120 x 140 | 420 g |
F35 01 | Communication Module | – | – | 30 x 100 x 120 | 170 g |
F8627X | Digital I/O Mixed Module | 8 DI / 8 DO | 24 V DC | 40 x 100 x 120 | 200 g |
F7553 | Profibus Communication Module | – | 5 V DC | 30 x 100 x 120 | 180 g |
FAQs – HIMA F30 03
Q1: What is the primary function of the HIMA F30 03 module?
A1: The F30 03 serves as a digital input module for receiving and monitoring discrete signals in safety-related applications.
Q2: Is the F30 03 suitable for use in SIL 3 applications?
A2: Yes, it is certified for SIL 3 per IEC 61508 and is widely used in critical safety instrumented systems.
Q3: Can the F30 03 be replaced while the system is running?
A3: Yes, it supports hot-swapping, allowing the module to be replaced without shutting down the entire system.
Q4: Which tools are used for configuring the F30 03 module?
A4: HIMA’s SILworX or ELOP II software is used for programming and configuration.
Q5: How can I tell if the F30 03 is malfunctioning?
A5: The module features onboard diagnostic LEDs and can report faults to the system software interface.
Q6: Is the F30 03 compatible with older HIMA systems?
A6: The F30 03 is compatible with HIMax and HIQuad platforms; compatibility with older systems should be verified case-by-case.