Product Introduction: HIMA F31 SPS D0171
The HIMA F31 SPS D0171 is a high-performance safety controller module specifically engineered for use in functional safety applications within critical industrial sectors such as oil and gas, chemical processing, and power generation. Designed and manufactured by HIMA, a global leader in safety automation solutions, the F31 SPS D0171 is part of the HIMax and HIQuad X series, known for their exceptional reliability, scalability, and SIL 3 certification under IEC 61508 standards.
This module is a programmable safety logic controller that ensures seamless integration within distributed control systems. It supports safe input/output processing and communicates through high-integrity protocols, making it a vital component for maintaining system uptime and protecting both people and infrastructure.
Product Advantages
-
Certified Safety: Complies with IEC 61508 SIL 3 requirements, ensuring the highest level of functional safety.
-
Robust Construction: Designed for harsh environments with high resistance to vibration, temperature fluctuations, and electromagnetic interference.
-
Redundant Architecture: Supports redundant configurations, increasing fault tolerance and minimizing downtime.
-
Flexible Integration: Seamlessly integrates with HIMA’s HIMax or HIQuad X systems and interfaces with third-party systems.
-
Long Service Life: Industrial-grade build with low maintenance and a long operational lifespan.
-
Real-Time Processing: Fast cycle times and deterministic behavior ensure rapid and reliable decision-making.
Technical Specifications
Parameter | Specification |
---|---|
Model | F31 SPS D0171 |
Manufacturer | HIMA |
Series | HIMax / HIQuad X |
Function | Safety PLC Module / Safety Controller |
Certification | IEC 61508 SIL 3 |
Voltage Supply | 24 V DC (±20%) |
Power Consumption | Max. 5 W |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +85°C |
Humidity | 5% to 95%, non-condensing |
Dimensions | 257 x 114 x 66 mm |
Weight | 1.2 kg |
Mounting | DIN rail mounting |
Communication Interfaces | RS485, SafeEthernet |
Programming | HIMA ELOP II / SILworX |
Response Time | < 10 ms |
Redundancy Support | Yes |
Diagnostic Features | Integrated self-monitoring, fault logging |
Applications
The HIMA F31 SPS D0171 is widely deployed across industries where safety and availability are paramount. Common application areas include:
-
Oil and Gas: Emergency shutdown systems (ESD), fire and gas systems (F&G)
-
Chemical Processing Plants: Process safety interlock systems
-
Power Generation: Turbine control, boiler protection, and safety shutdown systems
-
Railway Technology: Safety control for signaling and interlocking systems
-
Pharmaceuticals: Batch process control with functional safety
-
Industrial Automation: Machine safety, robotic safety interfaces
Compatible Models / Systems
The F31 SPS D0171 is designed to work with and complement various HIMA components. Below are some key compatible models:
-
HIMax X-CPU 01
-
HIMax X-SIO 01/02
-
HIQuad X-BI 01
-
HIQuad X-AI 01
-
H41q/H51q Controllers
-
X-COM Communication Modules
These modules can be integrated together using SafeEthernet or other high-integrity industrial bus systems to form a complete safety system.
Installation Instructions
-
Preparation: Before installation, ensure the system is powered down and ESD protection is in place.
-
DIN Rail Mounting: Mount the F31 SPS D0171 module securely on a 35 mm DIN rail in a protected enclosure.
-
Wiring: Connect the 24V DC power supply to the terminal block as per the HIMA wiring schematic.
-
Communication Setup: Use certified cables to connect to SafeEthernet or RS485 interfaces. Ensure proper shielding and grounding.
-
Configuration: Use the SILworX or ELOP II configuration tools to set up logic, test interlocks, and enable diagnostics.
-
Testing: Run system diagnostics to verify module health, I/O functionality, and system redundancy.
-
Commissioning: After all tests pass, proceed with safety validation and commissioning.
Related Models (Same Series or Functionality)
Model | Description | Voltage | Dimensions (mm) | Weight | Series |
---|---|---|---|---|---|
F30 CPU D0011 | HIMax CPU Module | 24 VDC | 50 x 160 x 120 | 580 g | HIMax |
F60 DI D0241 | Digital Input Module, 24 ch | 24 VDC | 50 x 160 x 120 | 500 g | HIMax |
F35 AI D0012 | Analog Input Module, SIL 3 | 24 VDC | 50 x 160 x 120 | 540 g | HIMax |
F31 DO D0014 | Digital Output Module | 24 VDC | 50 x 160 x 120 | 510 g | HIQuad X |
H41q-HS | High-speed Safety Controller | 24 VDC | 45 x 160 x 115 | 480 g | HIQuad |
X-COM 01 | Communication Module for SafeEthernet | 24 VDC | 35 x 160 x 100 | 430 g | HIMax |
Popular HIMA Models
Model | Function | Voltage | Dimensions (mm) | Weight | Application |
---|---|---|---|---|---|
H51q | Programmable Safety Controller | 24 VDC | 80 x 160 x 120 | 650 g | ESD / BMS |
X-CPU 01 | Central Processor Unit for HIMax | 24 VDC | 50 x 160 x 120 | 560 g | SIL 3 Control Systems |
F60 DI D0241 | Digital Input, 24-channel | 24 VDC | 50 x 160 x 120 | 500 g | Input Redundancy |
F60 DO D0202 | Digital Output, 16-channel | 24 VDC | 50 x 160 x 120 | 510 g | Safety Actuator Controls |
F35 AI D0012 | Analog Input SIL Module | 24 VDC | 50 x 160 x 120 | 540 g | Process Signal Monitoring |
X-HART | HART Communication Interface | 24 VDC | 50 x 160 x 120 | 500 g | Field Device Integration |
H41q-HS | High-Speed Controller | 24 VDC | 45 x 160 x 115 | 480 g | Machine Safety |
F30 PSU D1002 | Power Supply Unit | 24 VDC | 100 x 160 x 120 | 700 g | HIMax System Powering |
Frequently Asked Questions (FAQ)
Q1: What type of system is the F31 SPS D0171 suitable for?
A1: It is ideal for safety-critical systems requiring SIL 3 certification, such as ESD, F&G, and other process safety applications.
Q2: Can the F31 SPS D0171 be used in a redundant configuration?
A2: Yes, it supports full redundancy, including CPU, I/O, and communication paths to increase system availability.
Q3: Which software is needed to configure the F31 SPS D0171?
A3: HIMA’s SILworX or ELOP II is used for programming, diagnostics, and system configuration.
Q4: Is it compatible with third-party systems?
A4: Yes, it supports open communication protocols and interfaces for integration with third-party DCS or SCADA systems.
Q5: What diagnostics features does the module provide?
A5: It includes continuous self-monitoring, fault detection, time-stamped logging, and remote diagnostics.
Q6: What maintenance is required for the F31 SPS D0171?
A6: Very minimal maintenance is needed. Routine system diagnostics and visual inspections are recommended to ensure continuous performance.
HIMA F31 SPS D0171 Output Amplifier Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |