Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Honeywell 10012/1/2 Module
Product Introduction
The Honeywell 10012/1/2 is a highly reliable and robust industrial I/O module designed for mission-critical automation systems. As a part of Honeywell’s reputable TDC 3000 and TPS system families, the 10012/1/2 module ensures seamless integration within distributed control system (DCS) environments. Engineered with precision, it supports real-time control applications in power generation, petrochemical, oil & gas, and manufacturing industries.
Built to meet stringent industrial standards, this module offers excellent performance in terms of accuracy, stability, and long-term durability. The 10012/1/2 is typically used for interfacing field instrumentation with control systems, ensuring that analog and digital signals are accurately processed and transmitted.
With a modular construction, Honeywell 10012/1/2 provides easy installation, replacement, and maintenance, which is essential for systems requiring high uptime.
<br>
Product Advantages
-
High Reliability: Designed to operate continuously in harsh industrial environments with minimal failure rates.
-
Robust Signal Processing: Ensures accurate analog/digital signal conversion and communication.
-
Seamless Integration: Compatible with Honeywell TDC 3000 and TPS platforms, simplifying system expansion and upgrades.
-
Modular Design: Simplifies maintenance and replacement without system downtime.
-
Low Power Consumption: Energy-efficient operation reduces operational costs over time.
-
Long Lifecycle Support: Honeywell provides long-term support and spare availability, ensuring the module remains serviceable for years.
<br>
Technical Specifications
Parameter | Specification |
---|---|
Model Number | Honeywell 10012/1/2 |
Description | I/O Module for Honeywell TDC 3000 / TPS |
Input Type | Analog/Digital Signal Input/Output |
Communication | FTA (Field Termination Assembly) Compatible |
Operating Voltage | 24 VDC (typical) |
Power Consumption | ≤ 5 W |
Input Channels | 8–16 channels (depending on configuration) |
Isolation | Optical isolation between channels |
Mounting Type | DIN Rail / Chassis Mount |
Operating Temperature | 0°C to +60°C |
Storage Temperature | -40°C to +85°C |
Relative Humidity | 5%–95% non-condensing |
Dimensions | 20.32 × 128.4 × 160 mm |
Weight | 0.213 kg |
Compliance | CE, RoHS, UL certified |
<br>
Applications
The Honeywell 10012/1/2 module is widely deployed in the following sectors:
-
Oil and Gas: Process automation and safety control systems
-
Power Generation: Turbine control, load dispatching, and substation automation
-
Petrochemical Plants: Reactor control and safety interlocks
-
Water Treatment: Supervisory control and real-time monitoring
-
Pharmaceuticals: Precise batch control and data logging
-
Manufacturing Automation: Machine control, diagnostics, and status indication
Its versatility in analog and digital I/O support makes it suitable for a broad spectrum of industrial process control tasks.
<br>
Compatible Models
The Honeywell 10012/1/2 module can be used alongside the following Honeywell modules and systems:
-
Honeywell 51304511-100
-
Honeywell 51196694-100
-
Honeywell 51400955-100
-
Honeywell 10024/I/F
-
Honeywell 10024/I/1
-
Honeywell 10100/2/1
-
Honeywell 51202329-112
These modules work together to form a complete control and monitoring system within Honeywell’s DCS environment.
<br>
Installation Instructions
-
Power Off the System: Ensure the DCS system is shut down before beginning installation.
-
Mounting: Mount the 10012/1/2 module securely onto the DIN rail or into the control chassis. Ensure proper ventilation around the unit.
-
Wiring: Connect field wiring to the module via FTA connectors. Use proper shielding and grounding practices to minimize noise.
-
System Integration: Link the module to the controller via system bus as per Honeywell’s system architecture.
-
Power Up and Test: Once connected, power up the system and validate the module operation through the system diagnostics.
-
Calibration/Configuration: Use Honeywell’s configuration software to calibrate the input/output parameters if needed.
Note: Refer to Honeywell’s technical manuals for detailed wiring diagrams and safety instructions.
<br>
Related Models (Same Series or Functionally Similar)
Model | Description | Voltage | Channels | Dimensions (mm) | Weight (g) |
---|---|---|---|---|---|
10012/1/1 | I/O Module, Basic | 24 VDC | 8 | 120×100×40 | 340 |
10024/I/F | Input Module, Fast Response | 24 VDC | 16 | 120×100×40 | 355 |
10024/I/1 | Input Module, General Purpose | 24 VDC | 16 | 120×100×40 | 350 |
10100/2/1 | Output Module, Relay Type | 24 VDC | 8 | 130×100×45 | 370 |
10201/2/1 | I/O Module with Diagnostic Feedback | 24 VDC | 8 | 120×100×40 | 365 |
10202/2/2 | Input Module, High-Resolution Analog | 24 VDC | 8 | 130×100×45 | 375 |
<br>
8 Popular Honeywell Models
Model Number | Description | Voltage | Channels | Dimensions (mm) | Weight (g) |
---|---|---|---|---|---|
CC-TDIL01 | Digital Input Module | 24 VDC | 16 | 130×100×45 | 370 |
CC-PAIH01 | Analog Input Module | 24 VDC | 8 | 130×100×45 | 360 |
CC-PDOB01 | Digital Output Module | 24 VDC | 16 | 130×100×45 | 365 |
CC-TDOR11 | Relay Output Module | 24 VDC | 8 | 120×100×40 | 355 |
CC-PCF901 | Control Processor Interface | 24 VDC | N/A | 150×100×50 | 450 |
CC-PDIL01 | DI Module with LED Indication | 24 VDC | 16 | 130×100×45 | 370 |
CC-TFB811 | Field Bus Interface Module | 24 VDC | N/A | 140×100×45 | 380 |
51196655-100 | TDC 3000 System Interface Module | 24 VDC | N/A | 150×100×45 | 400 |
<br>
Frequently Asked Questions (FAQ)
Q1: What systems is the Honeywell 10012/1/2 compatible with?
A1: The 10012/1/2 is compatible with Honeywell TDC 3000 and TPS systems. It integrates smoothly with other Honeywell I/O and control modules.
<br>
Q2: Is the module hot-swappable?
A2: No, it is recommended to power down the system before replacing or installing the 10012/1/2 module to avoid damage and ensure safety.
<br>
Q3: What kind of signals does the 10012/1/2 support?
A3: It supports both analog and digital signal processing, depending on the system configuration and application.
<br>
Q4: How can I diagnose faults in the module?
A4: The module has LED indicators for each channel and system fault. Additionally, diagnostics can be done via Honeywell’s system interface.
<br>
Q5: What is the operating environment for this module?
A5: It operates within a temperature range of 0°C to +60°C and can be stored in -40°C to +85°C, suitable for most industrial control rooms.
<br>
Q6: Is technical support available for older modules like 10012/1/2?
A6: Yes, Honeywell offers extended lifecycle services and spare parts for legacy systems, including the 10012/1/2 module.
<br>
Honeywell 10012/1/2 Module CPU Flash
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |