Product Overview for Honeywell 2MLF-AD16A
The Honeywell 2MLF-AD16A is a high-performance, industrial-grade analog input module designed for use in complex control systems. This module is part of Honeywell’s extensive line of advanced process control solutions, offering precise measurement and data acquisition capabilities for a variety of applications. It is commonly used in industries such as manufacturing, oil and gas, chemical processing, and energy production, providing reliable and accurate monitoring of various analog signals.
Product Advantages
-
High Accuracy: The 2MLF-AD16A module ensures precise conversion of analog signals into digital data, with minimal error rates.
-
Wide Input Range: This module supports a wide range of input voltages and currents, offering versatility for different types of sensor integrations.
-
Rugged and Reliable: Built to withstand harsh industrial environments, the module is designed with durability in mind to ensure long-term reliability in various operational conditions.
-
Compatibility with Honeywell Systems: It seamlessly integrates into Honeywell’s control systems, ensuring smooth communication and control for industrial processes.
-
Easy Installation: The 2MLF-AD16A is designed for straightforward installation and setup, reducing downtime and simplifying maintenance.
-
Enhanced Signal Processing: This module can process signals quickly, making it ideal for applications requiring real-time data monitoring and control.
Technical Specifications
Parameter | Value |
---|---|
Dimensions | 113 x 98 x 27mm |
Weight | 0.115kg |
Voltage | 24V DC (nominal) |
Input Range | ±10V or 4-20mA |
Resolution | 16-bit |
Accuracy | ±0.1% of full scale |
Operating Temp | -20°C to 60°C |
Mounting | DIN rail or panel mounting |
Signal Isolation | 1500V AC |
Applications
The Honeywell 2MLF-AD16A module is used in several industries where high-precision control is required. Its applications include:
-
Process Control: In manufacturing plants, it helps monitor and control the processes that involve analog signals, such as temperature, pressure, and flow.
-
Energy Management: It is ideal for monitoring power usage and controlling energy systems within industrial facilities.
-
Automation: In automated production systems, it interfaces with sensors and other control systems to ensure optimal performance and minimal downtime.
-
Oil and Gas: Used for monitoring critical variables in production and refining processes, where continuous, real-time data is crucial.
Compatible Models
The 2MLF-AD16A is compatible with several other Honeywell products, including:
-
Honeywell 2MLF-D16A (Digital Input Module)
-
Honeywell 2MLF-AD08A (Analog Input Module with 8 Channels)
-
Honeywell 2MLF-D08A (Digital Output Module)
-
Honeywell 2MLF-AP16A (Analog Output Module)
-
Honeywell 2MLF-D32A (32-Channel Digital Input Module)
-
Honeywell 2MLF-AP08A (Analog Output Module with 8 Channels)
Installation Instructions
-
Preparation: Ensure the power supply is turned off before installation to prevent any electrical accidents.
-
Mounting: The module is designed for DIN rail or panel mounting. Secure it using appropriate mounting screws or clips, ensuring a stable and vibration-free installation.
-
Wiring: Connect the input signals to the module’s terminals according to the manufacturer’s wiring diagram, ensuring the connections are tight and secure.
-
System Integration: Once the module is physically installed, integrate it into the control system via the appropriate communication protocols, such as MODBUS or Profibus.
-
Powering Up: After all connections are confirmed, power on the system. Verify the module’s status indicators to ensure it is functioning correctly.
-
Testing: Perform a system check by inputting known signals and verifying the readings from the module.
Recommended Models (Similar or Related)
Model | Description | Voltage | Channels | Weight | Dimensions |
---|---|---|---|---|---|
Honeywell 2MLF-AD08A | 8-channel analog input module | 24V DC | 8 | 300g | 130mm x 95mm x 45mm |
Honeywell 2MLF-D16A | 16-channel digital input module | 24V DC | 16 | 320g | 135mm x 100mm x 50mm |
Honeywell 2MLF-AP08A | 8-channel analog output module | 24V DC | 8 | 320g | 130mm x 95mm x 45mm |
Honeywell 2MLF-D32A | 32-channel digital input module | 24V DC | 32 | 500g | 150mm x 110mm x 60mm |
Honeywell 2MLF-AD32A | 32-channel analog input module | 24V DC | 32 | 500g | 150mm x 110mm x 60mm |
Honeywell 2MLF-AP16A | 16-channel analog output module | 24V DC | 16 | 350g | 135mm x 100mm x 50mm |
Popular Honeywell Models
Model | Description | Voltage | Weight | Dimensions |
---|---|---|---|---|
Honeywell 2MLF-AD16A | Analog input module (16 channels) | 24V DC | 350g | 130mm x 95mm x 45mm |
Honeywell 2MLF-D16A | Digital input module (16 channels) | 24V DC | 320g | 135mm x 100mm x 50mm |
Honeywell 2MLF-AP08A | Analog output module (8 channels) | 24V DC | 320g | 130mm x 95mm x 45mm |
Honeywell 2MLF-D08A | Digital output module (8 channels) | 24V DC | 300g | 130mm x 95mm x 45mm |
Honeywell 2MLF-AD08A | Analog input module (8 channels) | 24V DC | 300g | 130mm x 95mm x 45mm |
Honeywell 2MLF-D32A | Digital input module (32 channels) | 24V DC | 500g | 150mm x 110mm x 60mm |
Honeywell 2MLF-AP16A | Analog output module (16 channels) | 24V DC | 350g | 135mm x 100mm x 50mm |
Honeywell 2MLF-AD32A | Analog input module (32 channels) | 24V DC | 500g | 150mm x 110mm x 60mm |
FAQ
Q1: What types of signals can the Honeywell 2MLF-AD16A module accept?
A1: The module can accept both voltage signals (±10V) and current signals (4-20mA), making it versatile for a wide range of applications.
Q2: How many channels does the 2MLF-AD16A module support?
A2: The module supports 16 analog input channels.
Q3: Can the Honeywell 2MLF-AD16A module be integrated with third-party control systems?
A3: Yes, it is compatible with systems using standard communication protocols such as MODBUS and Profibus.
Q4: What is the operating temperature range for the 2MLF-AD16A module?
A4: The module operates in a temperature range of -20°C to 60°C.
Q5: How is the module mounted?
A5: The module can be mounted on a DIN rail or directly onto a panel, providing flexibility for various installation setups.
Q6: Is the Honeywell 2MLF-AD16A module suitable for use in hazardous environments?
A6: While it is designed for industrial environments, for hazardous applications, it’s recommended to consult Honeywell’s specific product guidelines for compatibility with hazardous area requirements.
Honeywell 2MLF-AD16A analog/digital conversion module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |