Honeywell 900A01-0202 Product Overview
The Honeywell 900A01-0202 is a high-performance pressure transmitter designed for industrial applications. It provides accurate and reliable pressure measurement in harsh environments, making it suitable for industries such as oil & gas, chemical processing, water treatment, and HVAC.
This transmitter features robust construction, advanced signal conditioning, and long-term stability, ensuring consistent performance even under extreme conditions.
Product Advantages
- High Accuracy – Delivers precise pressure measurements with minimal deviation.
- Durability – Built with industrial-grade materials for resistance to corrosion and vibration.
- Wide Operating Range – Suitable for various pressure ranges and media types.
- Easy Installation – Compact design with multiple mounting options.
- Long-Term Stability – Minimal drift over time, reducing maintenance needs.
- Compliance – Meets industry standards for safety and performance.
Technical Specifications
Parameter | Value |
---|---|
Model Number | 900A01-0202 |
Pressure Range | 0-100 psi (adjustable) |
Output Signal | 4-20 mA, 2-wire |
Accuracy | ±0.25% of full scale |
Power Supply | 12-30 VDC |
Operating Temp. | -40°C to 85°C (-40°F to 185°F) |
Process Connection | 1/4″ NPT male |
Housing Material | Stainless steel |
Electrical Connection | M12 connector |
Dimensions | 68 x 107 x 78 mm |
Weight | 0.44kg |
Ingress Protection | IP67 |
Applications
- Oil & Gas – Wellhead monitoring, pipeline pressure measurement.
- Chemical Processing – Reactor pressure control, corrosive media handling.
- Water Treatment – Pump protection, tank level monitoring.
- HVAC Systems – Air and refrigerant pressure sensing.
- Industrial Automation – Hydraulic and pneumatic systems.
Compatible & Recommended Accessories
- Mounting Bracket – 900M01-0001 (for secure installation).
- Signal Conditioner – 900S02-0100 (for signal amplification).
- Protective Enclosure – 900E03-0050 (for extreme environments).
- Extension Cable – 900C01-0150 (for remote installations).
Installation Instructions
- Mounting – Secure the transmitter using the provided bracket or direct threading.
- Wiring – Connect the 4-20 mA output to the control system using shielded cable.
- Calibration – Verify zero and span settings before operation.
- Testing – Apply pressure and check signal output for accuracy.
- Sealing – Ensure all connections are properly sealed for IP67 compliance.
Recommended Similar Models (Same Series)
Model | Pressure Range | Output | Accuracy | Voltage | Dimensions | Weight |
---|---|---|---|---|---|---|
900A01-0201 | 0-50 psi | 4-20 mA | ±0.25% | 12-30 VDC | 120x80x50 mm | 0.5 kg |
900A01-0203 | 0-200 psi | 4-20 mA | ±0.25% | 12-30 VDC | 120x80x50 mm | 0.5 kg |
900A01-0204 | 0-500 psi | 4-20 mA | ±0.35% | 12-30 VDC | 120x80x50 mm | 0.6 kg |
900A01-0205 | 0-1000 psi | 4-20 mA | ±0.5% | 12-30 VDC | 130x90x60 mm | 0.8 kg |
900A01-0206 | -14.7 to 15 psi | 4-20 mA | ±0.25% | 12-30 VDC | 120x80x50 mm | 0.5 kg |
900A01-0207 | 0-10,000 psi | 4-20 mA | ±1.0% | 12-30 VDC | 150x100x70 mm | 1.2 kg |
Popular Honeywell Models (Other Series)
Model | Type | Range | Output | Voltage | Dimensions | Weight |
---|---|---|---|---|---|---|
HPT304-0001 | Absolute Pressure | 0-30 psi | 0.5-4.5 V | 5 VDC | 25x25x10 mm | 0.05 kg |
HSCDRRN005ND | Differential | ±5 psi | I2C/SPI | 3.3 VDC | 15x15x8 mm | 0.02 kg |
TSCDANN150PG | Gauge Pressure | 0-150 psi | Analog | 10-30 VDC | 50x50x20 mm | 0.3 kg |
MLH100PSB01A | High Pressure | 0-100 psi | 4-20 mA | 12-30 VDC | 80x60x40 mm | 0.4 kg |
PX3AN1BS100P | Industrial | 0-100 psi | RS485 | 24 VDC | 100x70x50 mm | 0.7 kg |
MIPAN2AB0100 | Miniature | 0-100 psi | Analog | 5 VDC | 20x20x10 mm | 0.03 kg |
PXN2AN1BS050 | OEM Pressure | 0-50 psi | I2C | 3.3 VDC | 18x18x8 mm | 0.01 kg |
HSCDANN001BA | Board Mount | 0-1 psi | Analog | 5 VDC | 10x10x5 mm | 0.005 kg |
Frequently Asked Questions (FAQ)
Q1: What is the operating temperature range of the 900A01-0202?
A1: The transmitter operates between -40°C to 85°C (-40°F to 185°F).
Q2: Can this transmitter measure corrosive media?
A2: Yes, the stainless steel housing and diaphragm provide resistance to corrosive substances.
Q3: What is the expected lifespan of this sensor?
A3: With proper installation, the sensor can last 10+ years under normal conditions.
Q4: Is the output signal adjustable?
A4: Yes, the 4-20 mA output can be calibrated for different pressure ranges.
Q5: Does it require regular recalibration?
A5: For optimal performance, annual recalibration is recommended.
Q6: Can it be used in explosive environments?
A6: No, this model is not ATEX-certified. For hazardous areas, consider the 900A01-EX series.