Honeywell CC-PAIN01 Product Documentation
Product Description
The Honeywell CC-PAIN01 is an advanced Analog Input Module, designed as part of Honeywell’s Experion Process Knowledge System (PKS) Series C family. It delivers superior performance in process automation environments, supporting multiple analog input signals and providing accurate, real-time data acquisition for critical process control applications. With robust industrial-grade construction, this module ensures reliable operation in challenging conditions, making it ideal for industries such as oil & gas, chemical processing, power generation, and manufacturing.
The CC-PAIN01 features integrated diagnostic capabilities and seamless communication with the Control Processor, enhancing system reliability and simplifying maintenance activities. It supports HART pass-through functionality, enabling remote configuration and monitoring of field devices, which increases operational efficiency and minimizes downtime.
Product Advantages
-
High Precision Measurement
Provides accurate and stable analog signal measurements to ensure process accuracy. -
Wide Compatibility
Fully compatible with Honeywell’s Experion PKS Series C and supports HART-enabled devices for flexible integration. -
Enhanced Diagnostics
Built-in diagnostics detect wiring issues and module faults, reducing troubleshooting time. -
Hot-Swappable Module
Can be replaced without shutting down the system, improving system availability and reducing downtime. -
Robust Design
Designed for harsh industrial environments, ensuring long-term reliability and performance. -
Ease of Installation and Maintenance
User-friendly design with clear labeling and simple wiring configuration speeds up installation and reduces maintenance complexity.
Technical Specifications
Parameter | Specification |
---|---|
Product Name | Honeywell CC-PAIN01 |
Module Type | Analog Input Module |
Supported Signals | 4-20 mA, HART |
Number of Channels | 16 Channels |
Voltage Range | 24 VDC nominal |
Power Consumption | 3.5 W |
Dimensions | 63.5 x 124.46 x 307.34 mm |
Weight | 0.299 kg |
Operating Temperature Range | -40°C to +70°C |
Storage Temperature Range | -40°C to +85°C |
Relative Humidity | 5% to 95%, non-condensing |
Isolation Voltage | 1500 VDC channel-to-channel and to system |
Communication Protocol | FTE (Fault Tolerant Ethernet) |
Certification | CE, ATEX, UL, IECEx |
Applications
-
Oil & Gas Industry
Reliable data acquisition for pipeline monitoring, refining operations, and wellhead control systems. -
Chemical Processing
Precise input measurement for chemical reaction monitoring and process control. -
Power Generation
Accurate input for monitoring temperature, pressure, and flow rates in power plants. -
Water & Wastewater Treatment
Supports automation for water quality monitoring and process optimization. -
Pharmaceutical Manufacturing
Provides critical input data for batch process control and environmental monitoring. -
Pulp and Paper Industry
Ensures proper control in pulp preparation, bleaching, and paper production processes.
Compatible Models
-
CC-PCNT01 — ControlNet Interface Module
-
CC-PCF901 — Fieldbus Interface Module
-
CC-PDIL01 — Digital Input Module
-
CC-PDOB01 — Digital Output Module
-
CC-TAIX11 — Analog Input Terminal Assembly
-
CC-TAOX11 — Analog Output Terminal Assembly
Installation Guide
-
Preparation
Ensure power is turned off before installation. Verify the environment meets Honeywell’s installation specifications. -
Mounting
Install the CC-PAIN01 module into the appropriate slot on the Universal IO baseplate. -
Wiring
Connect the field wiring to the terminal assembly. Use shielded twisted-pair cables for analog signals and follow Honeywell wiring diagrams. -
Power Supply Connection
Connect the module to the 24 VDC power supply, ensuring correct polarity. -
Module Configuration
Use Honeywell’s Experion Engineering Tools to configure channel types, scaling, and diagnostics settings. -
Verification
Power up the system, verify module recognition by the controller, and test each channel with simulated inputs. -
Commissioning
Perform system commissioning according to the site procedure, including full loop checks.
Related Models (Same Series or Similar)
Model Number | Description | Voltage | Channels | Dimensions (mm) | Weight |
---|---|---|---|---|---|
CC-PAOH01 | Analog Output Module | 24 VDC | 8 Channels | 145 x 55 x 136 | 0.38 kg |
CC-PDIL01 | Digital Input Module | 24 VDC | 32 Channels | 145 x 55 x 136 | 0.40 kg |
CC-PDOB01 | Digital Output Module | 24 VDC | 32 Channels | 145 x 55 x 136 | 0.42 kg |
CC-TAIX11 | Analog Input Terminal Assembly | – | – | 145 x 55 x 136 | 0.30 kg |
CC-TAOX11 | Analog Output Terminal Assembly | – | – | 145 x 55 x 136 | 0.30 kg |
CC-PCNT01 | ControlNet Interface Module | – | – | 145 x 55 x 136 | 0.45 kg |
Popular Honeywell Models
Model Number | Description | Voltage | Channels | Dimensions (mm) | Weight |
---|---|---|---|---|---|
CC-PAIH01 | High-Level Analog Input Module | 24 VDC | 16 Channels | 145 x 55 x 136 | 0.38 kg |
CC-PDIL01 | Digital Input Module | 24 VDC | 32 Channels | 145 x 55 x 136 | 0.40 kg |
CC-PDOB01 | Digital Output Module | 24 VDC | 32 Channels | 145 x 55 x 136 | 0.42 kg |
CC-PAOH01 | Analog Output Module | 24 VDC | 8 Channels | 145 x 55 x 136 | 0.38 kg |
CC-PCNT01 | ControlNet Interface Module | – | – | 145 x 55 x 136 | 0.45 kg |
CC-PCF901 | Fieldbus Interface Module | – | – | 145 x 55 x 136 | 0.45 kg |
CC-TDIL01 | Digital Input Terminal Assembly | – | – | 145 x 55 x 136 | 0.30 kg |
CC-TDOX01 | Digital Output Terminal Assembly | – | – | 145 x 55 x 136 | 0.30 kg |
FAQ (Q&A Format)
Q1: What is the main function of the Honeywell CC-PAIN01 module?
A1: The Honeywell CC-PAIN01 is an analog input module designed to collect and process analog signals from field devices for accurate process monitoring and control.
Q2: Can the CC-PAIN01 module be hot-swapped during operation?
A2: Yes, the CC-PAIN01 supports hot-swapping, allowing the module to be replaced without shutting down the control system.
Q3: Is the CC-PAIN01 compatible with HART communication protocol?
A3: Yes, the module fully supports HART-enabled devices, enabling remote configuration and diagnostics.
Q4: What is the operating temperature range of the CC-PAIN01?
A4: The module operates reliably within a temperature range of -40°C to +70°C.
Q5: How many input channels does the CC-PAIN01 support?
A5: The CC-PAIN01 module supports 16 analog input channels.
Q6: What certifications does the CC-PAIN01 have for industrial use?
A6: The module is certified with CE, ATEX, UL, and IECEx standards, ensuring safe operation in various industrial environments.