Honeywell CC-TDOR01 51307087-175 Product Documentation
Product Introduction
The Honeywell CC-TDOR01 51307087-175 is a high-performance digital output module designed for industrial automation and control systems. It is part of Honeywell’s Experion® Process Knowledge System (PKS) and is widely used in process control applications. This module provides reliable and precise digital output signals to control various field devices such as valves, relays, and actuators.
The CC-TDOR01 module is known for its robust construction, high reliability, and compatibility with Honeywell’s control systems. It is designed to operate in harsh industrial environments, ensuring long-term stability and minimal maintenance requirements.
Product Advantages
- High Reliability: Built with industrial-grade components to ensure continuous operation in demanding environments.
- Easy Integration: Compatible with Honeywell’s Experion PKS and other control systems for seamless integration.
- Flexible Configuration: Supports multiple output configurations to meet diverse application requirements.
- Durability: Designed to withstand extreme temperatures, vibrations, and electrical noise.
- Diagnostic Capabilities: Provides real-time diagnostics for quick troubleshooting and maintenance.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | CC-TDOR01 51307087-175 |
Type | Digital Output Module |
Dimensions (LxWxH) | 120 mm x 45 mm x 110 mm |
Weight | 0.5 kg |
Operating Voltage | 24V DC (±10%) |
Output Channels | 16 channels |
Output Type | Relay / Transistor |
Current Rating | 2A per channel |
Isolation Voltage | 1500V AC |
Operating Temp. | -20°C to +70°C |
Protection Class | IP20 |
Communication | Backplane communication with Experion |
Applications
The CC-TDOR01 module is widely used in industries such as:
- Oil & Gas: For controlling valves and pumps in refinery processes.
- Chemical Processing: To manage actuators and safety shutdown systems.
- Power Generation: For turbine control and auxiliary system automation.
- Water Treatment: In pump control and filtration systems.
- Manufacturing: For automated production line controls.
Compatible & Recommended Models
The CC-TDOR01 module is often used alongside the following Honeywell products:
- CC-PDIL01 (Digital Input Module)
- CC-PAOX01 (Analog Output Module)
- CC-TAOX01 (Analog Input Module)
- CC-PDOR01 (Alternative Digital Output Module)
- CC-TDOX01 (High-Density Digital Output Module)
- CC-TAOD11 (Advanced Analog Output Module)
Installation Instructions
- Power Off: Ensure the control system is powered down before installation.
- Mounting: Secure the module in the designated slot of the Experion rack.
- Wiring: Connect field devices to the output terminals as per the wiring diagram.
- Configuration: Use Experion software to configure the module parameters.
- Testing: Power on the system and verify output functionality.
- Final Check: Ensure all connections are secure and diagnostics show no errors.
Recommended Related Models (Same Series)
Model Number | Type | Channels | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
CC-TDOR02 | Digital Output Module | 32 | 24V DC | 120x45x110 | 0.6 kg |
CC-TDOR03 | High-Speed DO Module | 16 | 24V DC | 120x45x110 | 0.55 kg |
CC-TDOR04 | Relay Output Module | 8 | 24V DC | 100x40x90 | 0.4 kg |
CC-TDOR05 | Isolated DO Module | 16 | 24V DC | 120x45x110 | 0.5 kg |
CC-TDOR06 | Fail-Safe DO Module | 16 | 24V DC | 120x45x110 | 0.5 kg |
CC-TDOR07 | Redundant DO Module | 16 | 24V DC | 130x50x120 | 0.7 kg |
Top 8 Popular Honeywell Models
Model Number | Type | Channels | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
CC-PDIL01 | Digital Input Module | 32 | 24V DC | 120x45x110 | 0.6 kg |
CC-PAOX01 | Analog Output Module | 8 | 24V DC | 120x45x110 | 0.5 kg |
CC-TAOX01 | Analog Input Module | 16 | 24V DC | 120x45x110 | 0.55 kg |
CC-TAOD11 | Advanced AO Module | 8 | 24V DC | 120x45x110 | 0.5 kg |
CC-PDOX01 | High-Density DI Module | 64 | 24V DC | 150x50x120 | 0.8 kg |
CC-PAID01 | Analog Input Module | 16 | 24V DC | 120x45x110 | 0.55 kg |
CC-TCNT01 | Counter Module | 4 | 24V DC | 100x40x90 | 0.4 kg |
CC-TRTD01 | RTD Input Module | 8 | 24V DC | 120x45x110 | 0.5 kg |
FAQ (Frequently Asked Questions)
Q1: What is the maximum load current per channel for the CC-TDOR01?
A1: The maximum load current per channel is 2A.
Q2: Can this module be used in hazardous environments?
A2: No, it is rated for general industrial use (IP20) and is not certified for hazardous areas.
Q3: Is the CC-TDOR01 compatible with non-Honeywell control systems?
A3: It is designed for Honeywell Experion PKS but may work with third-party systems with proper interface configuration.
Q4: What is the isolation voltage between channels?
A4: The isolation voltage between channels is 1500V AC.
Q5: How do I troubleshoot a faulty output channel?
A5: Use the built-in diagnostics in Experion software to check for errors and verify wiring connections.
Q6: Can the module be hot-swapped?
A6: No, the module should only be installed or removed when the system is powered off.
Honeywell CC-TDOR01 51307087-175 Digital Output Relay Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |