Honeywell CC-TFB412 Product Overview
The Honeywell CC-TFB412 is a high-performance Foundation Fieldbus communication module designed for industrial automation and process control applications. It is part of Honeywell’s Experion® Process Knowledge System (PKS), offering reliable and efficient communication between field devices and control systems.
This module is widely used in industries such as oil & gas, chemical processing, power generation, and pharmaceuticals, where precise and stable communication is critical.
Product Advantages
- High Reliability – Designed for harsh industrial environments with robust construction and long-term stability.
- Seamless Integration – Compatible with Honeywell’s Experion PKS and other Foundation Fieldbus systems.
- Redundancy Support – Ensures continuous operation even in case of a module failure.
- Easy Configuration – Supports plug-and-play functionality with user-friendly configuration tools.
- Low Maintenance – Durable design reduces downtime and servicing requirements.
- Wide Compatibility – Works with multiple Honeywell and third-party field devices.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | CC-TFB412 |
Communication Protocol | Foundation Fieldbus (FF) H1 |
Operating Voltage | 24V DC (±10%) |
Power Consumption | 2.5W (typical) |
Dimensions (L x W x H) | 120mm x 80mm x 40mm |
Weight | 0.5 kg |
Operating Temperature | -40°C to +70°C |
Humidity Range | 5% to 95% (non-condensing) |
Certifications | ATEX, IECEx, CE, SIL 2/3 compliant |
Redundancy Support | Yes (with additional modules) |
Applications
The CC-TFB412 is suitable for various industrial applications, including:
- Process Control Systems – Ensures stable communication in refining and chemical plants.
- Power Plants – Facilitates real-time monitoring and control.
- Oil & Gas – Used in offshore and onshore drilling operations.
- Pharmaceuticals – Supports precise control in sterile environments.
- Water Treatment – Manages flow and pressure control systems.
Compatible & Recommended Models
The CC-TFB412 works seamlessly with the following Honeywell products:
- CC-PDIL01 (I/O Module)
- CC-PDIL51 (Redundant I/O Module)
- CC-PAIM01 (Analog Input Module)
- CC-PAOX01 (Analog Output Module)
- CC-PDOR01 (Digital Output Module)
- CC-TAOX11 (Terminal Assembly)
Installation Instructions
- Mounting – Secure the module in a DIN rail or panel-mounted enclosure.
- Wiring – Connect the 24V DC power supply and Foundation Fieldbus cables as per the wiring diagram.
- Grounding – Ensure proper grounding to avoid electrical interference.
- Configuration – Use Honeywell’s Control Builder software to configure the module.
- Testing – Verify communication with field devices before full operation.
6 Related Models in the Same Series
Model | Type | Voltage | Dimensions | Weight | Key Feature |
---|---|---|---|---|---|
CC-TFB401 | Foundation Fieldbus Module | 24V DC | 120x80x40mm | 0.5 kg | Basic FF communication |
CC-TFB402 | Redundant FF Module | 24V DC | 120x80x40mm | 0.55 kg | Dual-channel redundancy |
CC-TFB411 | Enhanced FF Module | 24V DC | 120x80x40mm | 0.52 kg | Higher noise immunity |
CC-TFB414 | High-Speed FF Module | 24V DC | 120x80x40mm | 0.53 kg | Faster data transfer |
CC-TFB415 | IS (Intrinsically Safe) FF Module | 24V DC | 120x80x40mm | 0.56 kg | Hazardous area use |
CC-TFB416 | Advanced Diagnostics FF Module | 24V DC | 120x80x40mm | 0.54 kg | Built-in diagnostics |
8 Popular Honeywell Models (Other Series)
Model | Type | Voltage | Dimensions | Weight | Key Feature |
---|---|---|---|---|---|
CC-TAOX01 | Analog Output Terminal | 24V DC | 100x60x30mm | 0.3 kg | 16-channel AO |
CC-PDIL51 | Digital Input Module | 24V DC | 120x80x40mm | 0.5 kg | 32-channel DI |
CC-PAIM01 | Analog Input Module | 24V DC | 120x80x40mm | 0.48 kg | 16-channel AI |
CC-PAOX01 | Analog Output Module | 24V DC | 120x80x40mm | 0.49 kg | 8-channel AO |
CC-PDOR01 | Digital Output Module | 24V DC | 120x80x40mm | 0.51 kg | 16-channel DO |
CC-TDOB01 | Discrete Output Base | 24V DC | 100x60x30mm | 0.35 kg | DO termination |
CC-TAIB02 | Analog Input Base | 24V DC | 100x60x30mm | 0.34 kg | AI termination |
CC-TAOB01 | Analog Output Base | 24V DC | 100x60x30mm | 0.33 kg | AO termination |
6 Frequently Asked Questions (Q&A)
Q1: What is the maximum cable length supported by the CC-TFB412?
A1: The module supports up to 1,900 meters with standard Foundation Fieldbus cabling.
Q2: Is the CC-TFB412 compatible with non-Honeywell systems?
A2: Yes, it follows the Foundation Fieldbus standard, making it compatible with third-party FF systems.
Q3: Can the CC-TFB412 operate in hazardous areas?
A3: Yes, it is ATEX and IECEx certified for use in explosive atmospheres.
Q4: Does the CC-TFB412 support hot swapping?
A4: Yes, it supports hot swapping for minimal downtime during maintenance.
Q5: What software is needed to configure the CC-TFB412?
A5: Honeywell’s Control Builder or Experion PKS software is required for configuration.
Q6: What is the MTBF (Mean Time Between Failures) of the CC-TFB412?
A6: The MTBF is approximately 200,000 hours under normal operating conditions.
Honeywell CC-TFB412 51308311-275 Fieldbus 4 Link RED I0TA Interface Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
51308311-275, CC-TFB412, Fieldbus 4 Link RED I0TA Interface Module, Honeywell, Honeywell CC-TFB412 51308311-275