Honeywell DC-TAIX11 Detailed Product Overview
Product Introduction
The Honeywell DC-TAIX11 is a high-performance Analog Input Module designed for use within Honeywell’s distributed control systems (DCS), specifically in the Experion Process Knowledge System (PKS) and PlantScape control environments. The DC-TAIX11 module plays a crucial role in collecting analog data from field devices such as pressure transmitters, temperature sensors, and flow meters, converting these signals into a digital format for processing and monitoring.
Equipped with advanced signal conditioning, diagnostic capabilities, and fault tolerance, the DC-TAIX11 ensures reliability and accuracy in process automation and industrial applications. It integrates seamlessly into Honeywell’s C300 controller architecture and is widely used in oil and gas, chemical processing, pharmaceuticals, power generation, and other process-intensive industries.
Product Advantages
-
High Accuracy and Stability
The DC-TAIX11 provides superior analog signal acquisition with low noise and high resolution, maintaining consistent accuracy over extended periods. -
Robust Signal Conditioning
The module includes built-in filtering, linearization, and isolation features to protect the system from external disturbances and signal degradation. -
Enhanced Diagnostics
Offers real-time health monitoring and diagnostic feedback on input channels, enabling predictive maintenance and reducing downtime. -
Seamless System Integration
Fully compatible with Honeywell’s DCS infrastructure, ensuring plug-and-play integration and streamlined system configuration. -
Fail-Safe Design
Built with redundant communication pathways and protection mechanisms, the DC-TAIX11 supports critical control systems requiring high availability. -
Compact and Modular
Space-saving form factor that supports dense installation in control cabinets without compromising performance.
Technical Specifications
Parameter | Details |
---|---|
Model Number | DC-TAIX11 |
Description | Analog Input Module |
Input Channels | 16 Single-Ended Analog Inputs |
Input Signal Range | 0–20 mA, 4–20 mA, 0–10V, 1–5V |
Resolution | 16-bit |
Isolation | 1500 VDC Channel-to-System |
Accuracy | ±0.05% of Full Scale |
Update Rate | 10 ms per channel |
Diagnostics | Channel Fault Detection, Input Overrange |
Power Supply | 24 VDC |
Operating Temperature | 0°C to +60°C |
Storage Temperature | -40°C to +85°C |
Humidity | 5–95% RH (non-condensing) |
Mounting Type | DIN Rail Mountable |
Dimensions | 22 x 124 x 126 |
Weight | 1.6 kg |
Certifications | CE, UL, CSA, RoHS |
Compatible Systems | Honeywell Experion PKS, PlantScape |
Communication | I/O Link via FTA (Field Terminal Assembly) |
Applications
-
Oil and Gas Industry
Used for precise monitoring of pressure, flow, and temperature in upstream and downstream applications. -
Chemical and Petrochemical Plants
Enables reliable control and monitoring of critical parameters in continuous and batch processes. -
Pharmaceutical Manufacturing
Ensures accuracy in temperature and pH measurements for regulatory compliance and product quality. -
Power Generation
Vital in turbine control systems, boiler management, and auxiliary system monitoring. -
Water and Wastewater Management
Deployed in SCADA systems for real-time monitoring and environmental compliance. -
Pulp and Paper Industry
Supports analog measurements of steam flow, chemical dosing, and moisture control.
Compatible Models for Integration
The DC-TAIX11 is designed to work seamlessly with the following Honeywell components:
-
C300 Controller
-
Series 8 I/O Modules
-
FTA-IC800 Field Terminal Assembly
-
Honeywell PMIO Racks
-
Experion PKS I/O Network Adapters
-
Honeywell TPS Systems
-
HC900 Controller System
-
ControlEdge Systems
Installation Instructions
-
Preparation
Ensure the power is turned off and the system is properly grounded before beginning the installation. Confirm that the module and terminal blocks are free from dust and damage. -
Mounting
Mount the module on a standard DIN rail inside the control cabinet. Ensure adequate spacing for ventilation and cabling. -
Wiring
Connect field signals to the corresponding Field Terminal Assembly (FTA) using shielded cables. Verify polarity and signal type (e.g., voltage or current). -
Module Connection
Insert the DC-TAIX11 into the assigned slot on the I/O rack. Engage all locking clips to secure the module. -
System Configuration
Use Honeywell Control Builder or Experion Station to configure the I/O points, scaling, and alarms. Load configurations to the controller. -
Power-Up and Testing
Power up the system and validate input signals using system diagnostics and engineering tools. -
Calibration (If Required)
Calibrate analog channels according to application needs and regulatory requirements.
6 Related Models from the Same Series
Model | Description | Input Type | Channels | Voltage | Dimensions (mm) | Weight (g) |
---|---|---|---|---|---|---|
DC-TAOX11 | Analog Output Module | 4–20 mA, 0–10 V | 8 | 24 VDC | 145×50×130 | 460 |
DC-TDIL01 | Digital Input Module | Dry Contact | 16 | 24 VDC | 145×50×130 | 430 |
DC-TDOR01 | Digital Output Module | Relay | 8 | 24 VDC | 145×50×130 | 440 |
DC-PDIL01 | Pulse Digital Input Module | Pulse | 8 | 24 VDC | 145×50×130 | 450 |
DC-PDOX01 | Pulse Digital Output Module | Pulse/Relay | 8 | 24 VDC | 145×50×130 | 455 |
DC-TAIH51 | High Density Analog Input Module | 4–20 mA | 32 | 24 VDC | 145×60×130 | 470 |
8 Popular Honeywell Models
Model | Description | Function | Voltage | Dimensions (mm) | Weight (g) |
---|---|---|---|---|---|
CC-TDIL01 | Digital Input Module | 24VDC DI, 16 channels | 24 VDC | 145×50×130 | 435 |
CC-TDOR01 | Digital Output Module | Relay DO, 8 channels | 24 VDC | 145×50×130 | 440 |
CC-TAIX01 | Analog Input Module | 4–20 mA, 16 channels | 24 VDC | 145×50×130 | 450 |
CC-TAOX01 | Analog Output Module | 4–20 mA, 8 channels | 24 VDC | 145×50×130 | 455 |
CC-PDIL01 | Pulse Input Module | Pulse DI, 8 channels | 24 VDC | 145×50×130 | 430 |
CC-PDOX01 | Pulse Output Module | Pulse DO, 8 channels | 24 VDC | 145×50×130 | 445 |
CC-TCF901 | Field Control Processor | Controller Module | 24 VDC | 145×70×130 | 480 |
CC-TDOR11 | High Current Digital Output Module | Relay Output, 8 channels | 24 VDC | 145×50×130 | 445 |
Frequently Asked Questions (FAQ)
Q1: What kind of signals can the DC-TAIX11 process?
A1: The DC-TAIX11 supports analog signals including 0–20 mA, 4–20 mA, 0–10V, and 1–5V, making it versatile for a range of industrial sensors and transmitters.
Q2: Is the DC-TAIX11 hot-swappable?
A2: Yes, the module can be replaced while the system is powered on, provided proper hot-swap procedures are followed and the control system supports this feature.
Q3: What diagnostic features are included in the DC-TAIX11?
A3: The module includes channel fault detection, signal overrange indication, and input signal integrity checks to ensure system reliability and ease of maintenance.
Q4: Can the DC-TAIX11 be used in hazardous environments?
A4: While the module itself is not intrinsically safe, it can be paired with suitable barriers or installed in certified enclosures to meet hazardous area requirements.
Q5: How is the DC-TAIX11 configured?
A5: Configuration is done through Honeywell’s Control Builder or similar engineering tools, allowing you to set scaling, filtering, diagnostics, and alarms for each channel.
Q6: What is the warranty period for the DC-TAIX11?
A6: Honeywell typically offers a 12-month limited warranty, extendable under service agreements. Always verify warranty details with the supplier or integrator.
Honeywell DC-TAIX11 Analog Output IOTA Redundant
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |