Honeywell FS-BLIND-COM Product Introduction
The Honeywell FS-BLIND-COM is a high-performance blind communication module designed for integration with Honeywell’s fire and gas detection systems. This module facilitates seamless communication between blind sensors and the control panel, ensuring reliable and real-time monitoring of hazardous environments. It is widely used in industrial applications where safety and precision are critical.
The FS-BLIND-COM is engineered to meet stringent industry standards, offering robust performance in harsh conditions. Its compact design and easy installation make it a preferred choice for system integrators and safety engineers.
Product Advantages
- Reliable Communication: Ensures uninterrupted data transmission between blind sensors and the control panel.
- Durability: Built to withstand extreme temperatures, humidity, and corrosive environments.
- Easy Integration: Compatible with Honeywell’s fire and gas detection systems for seamless setup.
- Low Maintenance: Designed for long-term operation with minimal upkeep.
- Compact Design: Space-saving form factor ideal for crowded control panels.
- Compliance: Meets international safety and performance standards.
Technical Specifications
Parameter | Value |
---|---|
Dimensions | 140mm x 70mm x 25mm |
Weight | 0.25kg |
Operating Voltage | 24 VDC (±10%) |
Current Consumption | 50 mA (max) |
Communication Protocol | RS-485 / Modbus RTU |
Operating Temperature | -20°C to +60°C |
Humidity Range | 10% to 90% (non-condensing) |
Enclosure Rating | IP66 |
Certifications | ATEX, IECEx, UL |
Applications
The FS-BLIND-COM is suitable for:
- Oil and gas refineries
- Chemical processing plants
- Power generation facilities
- Pharmaceutical manufacturing
- Mining operations
- Any environment requiring reliable fire and gas detection
Compatible Products
The FS-BLIND-COM is designed to work with the following Honeywell models:
- FS-BLIND-SENSOR: Blind sensor for gas detection.
- FS-CONTROL-PANEL: Central control unit for system integration.
- FS-POWER-SUPPLY: 24V DC power supply module.
- FS-ALARM-MODULE: Alarm output module for notifications.
- FS-ISOLATOR: Signal isolator for noise reduction.
- FS-TERMINAL-BLOCK: Terminal block for wiring connections.
Installation Instructions
- Mounting: Secure the module to a DIN rail or flat surface using provided screws.
- Wiring: Connect the communication cables (RS-485) and power supply (24V DC) as per the wiring diagram.
- Configuration: Set the module address and communication parameters via the control panel.
- Testing: Verify communication with the blind sensors and control panel before finalizing installation.
- Enclosure: Ensure the enclosure is properly sealed to maintain IP66 rating.
Recommended Similar or Related Models
Model | Dimensions | Weight | Voltage | Key Feature |
---|---|---|---|---|
FS-BLIND-SENSOR | 100 mm x 50 mm x 30 mm | 0.3 kg | 24 VDC | Blind gas detection sensor |
FS-COMM-EXT | 150 mm x 90 mm x 45 mm | 0.7 kg | 24 VDC | Extended communication module |
FS-ANALOG-IO | 120 mm x 80 mm x 40 mm | 0.6 kg | 24 VDC | Analog I/O module for signal processing |
FS-DISPLAY-LCD | 200 mm x 120 mm x 50 mm | 1.2 kg | 24 VDC | LCD display for system monitoring |
FS-RELAY-OUT | 100 mm x 70 mm x 35 mm | 0.4 kg | 24 VDC | Relay output module for alarms |
FS-ISOLATOR-EX | 110 mm x 75 mm x 40 mm | 0.5 kg | 24 VDC | Explosion-proof signal isolator |
Popular Honeywell Models
Model | Dimensions | Weight | Voltage | Key Feature |
---|---|---|---|---|
Honeywell XNX | 180 mm x 140 mm x 60 mm | 1.5 kg | 24 VDC | Universal gas detector |
Honeywell Midas | 200 mm x 150 mm x 70 mm | 2.0 kg | 24 VDC | High-performance gas detector |
Honeywell SPS | 160 mm x 120 mm x 50 mm | 1.3 kg | 24 VDC | Smart pressure sensor |
Honeywell FS20 | 120 mm x 80 mm x 40 mm | 0.6 kg | 24 VDC | Flame detector |
Honeywell FS400 | 250 mm x 200 mm x 80 mm | 3.0 kg | 24 VDC | Multi-spectrum IR flame detector |
Honeywell FS10X | 100 mm x 70 mm x 30 mm | 0.4 kg | 24 VDC | Compact flame detector |
Honeywell FSG | 150 mm x 100 mm x 50 mm | 1.0 kg | 24 VDC | Gas detection controller |
Honeywell FST | 130 mm x 90 mm x 45 mm | 0.8 kg | 24 VDC | Toxic gas detector |
FAQ (Frequently Asked Questions)
Q1: What is the purpose of the FS-BLIND-COM module?
A1: The FS-BLIND-COM acts as a communication bridge between blind sensors and the control panel, ensuring real-time data transmission for safety monitoring.
Q2: Is the FS-BLIND-COM compatible with non-Honeywell systems?
A2: No, it is designed specifically for Honeywell fire and gas detection systems.
Q3: What is the maximum communication distance supported?
A3: The module supports up to 1200 meters over RS-485 with proper cabling.
Q4: Can the FS-BLIND-COM operate in explosive environments?
A4: Yes, it is ATEX and IECEx certified for use in hazardous areas.
Q5: How do I troubleshoot communication issues?
A5: Check wiring, address settings, and ensure the control panel supports Modbus RTU protocol.
Q6: What maintenance is required for the FS-BLIND-COM?
A6: Periodic inspection of connections and enclosure integrity is recommended, but no routine maintenance is needed.