Product Introduction – Honeywell MC-PSTX03 51304516-250
The Honeywell MC-PSTX03 51304516-250 is a high-performance I/O module specifically engineered for use in industrial automation and process control systems. As part of the Honeywell Experion PKS and TDC 3000 control platform, this module functions as a Primary Station Transmitter I/O, facilitating precise signal acquisition and communication between field instruments and control units. The module is integrated with Honeywell’s robust fault-tolerant architecture, making it a reliable solution for continuous plant operations.
It supports intelligent field devices and seamlessly handles analog or digital signal processing, depending on system requirements. With industrial-grade components and advanced diagnostics, the MC-PSTX03 ensures process integrity, data accuracy, and operational safety in demanding control environments such as oil & gas, chemical, pharmaceutical, and power generation sectors.
Product Advantages
-
High Reliability: Designed for mission-critical environments, ensuring continuous operation without interruptions.
-
Seamless Integration: Compatible with Honeywell Experion and TDC systems, reducing configuration and commissioning time.
-
Advanced Diagnostics: Real-time fault detection and diagnostics for proactive maintenance.
-
Compact Design: Optimized for cabinet space with lightweight construction, suitable for both retrofit and new installations.
-
Robust Communication: Enhanced I/O performance with high-speed signal transmission and minimal latency.
-
Reduced Downtime: Hot-swappable module support allows for field replacement without system shutdown.
Technical Specifications
Parameter | Description |
---|---|
Model Number | MC-PSTX03 |
Part Number | 51304516-250 |
Manufacturer | Honeywell |
Module Type | Primary Station Transmitter I/O Module |
System Compatibility | Experion PKS, TDC 3000 |
Input Channels | Multiple configurable analog or digital inputs |
Operating Voltage | 18–32 VDC |
Power Consumption | < 5 W |
Communication Protocol | Proprietary Honeywell protocol |
Operating Temperature | -40°C to +70°C |
Storage Temperature | -40°C to +85°C |
Humidity | 5% to 95% non-condensing |
Dimensions (W x H x D) | 100 mm x 150 mm x 40 mm |
Weight | 0.35kg |
Mounting Type | DIN rail or panel mounting |
Protection Rating | IP20 |
Applications
-
Oil and Gas Refineries: Monitoring pressure, temperature, and flow signals from field sensors.
-
Chemical Processing Plants: Acquiring analog input signals from transmitters for process control.
-
Pharmaceutical Manufacturing: Integrating precise I/O modules for controlled environments.
-
Power Generation Facilities: Collecting data from remote sensors for turbine control and monitoring.
-
Water Treatment Plants: Interfacing with instrumentation to maintain fluid and chemical levels.
-
Food & Beverage Industry: Supporting automation for hygienic and accurate process control.
Compatible Models for System Integration
-
Honeywell MC-TDODI4 – Digital Output Module
-
Honeywell MC-TDOY22 – Output Module
-
Honeywell MC-PDOY22 – Power Digital Output
-
Honeywell MC-TAMR03 – Analog Module Receiver
-
Honeywell MC-TDIY22 – Digital Input Module
-
Honeywell MC-TAIH14 – Analog Input Module
Installation Instructions
-
Power Down System: Always ensure the main control system is powered off before installation to avoid electrical hazards.
-
Mount the Module: Securely install the MC-PSTX03 module onto a DIN rail or flat panel in the designated control cabinet.
-
Connect Field Wiring: Use standard shielded cables for analog or digital signal connections. Ensure terminal polarity and grounding are correct.
-
Insert Module into Slot: Align the module with the backplane slot and insert it firmly until locked in position.
-
System Initialization: After installation, power on the system and allow the DCS to recognize the module automatically.
-
Configuration: Use Honeywell configuration tools or Experion software to map I/O channels and assign logic as needed.
-
Testing: Validate signal communication and perform loop checks before commissioning into live process.
Related Models in the Same Series
Model Number | Description | Voltage Range | Dimensions (mm) | Weight (g) |
---|---|---|---|---|
MC-TAMR03 | Analog Module Receiver | 18–32 VDC | 100x150x40 | 330 |
MC-TDIY22 | Digital Input Module | 18–32 VDC | 100x150x40 | 345 |
MC-TDOY22 | Digital Output Module | 18–32 VDC | 100x150x40 | 360 |
MC-PDOY22 | Power Digital Output Module | 18–32 VDC | 100x150x40 | 355 |
MC-TAIH14 | Analog Input High-Density Module | 18–32 VDC | 100x150x40 | 340 |
MC-TLPA02 | Pulse Accumulator Module | 18–32 VDC | 100x150x40 | 365 |
8 Popular Honeywell Models with Specifications
Model Number | Description | Voltage | Dimensions (mm) | Weight (g) |
---|---|---|---|---|
CC-PCF901 | Fieldbus Module | 24 VDC | 100x160x45 | 420 |
CC-TDIL01 | Digital Input Module | 24 VDC | 100x150x40 | 360 |
CC-TDOB01 | Digital Output Module | 24 VDC | 100x150x40 | 375 |
CC-PAIH01 | Analog Input Module | 24 VDC | 100x150x40 | 390 |
CC-PDIL01 | Digital Input (High Density) Module | 24 VDC | 100x150x40 | 400 |
CC-TCF901 | Control Function Module | 24 VDC | 100x150x40 | 410 |
CC-PUIO01 | Universal I/O Module | 24 VDC | 100x160x45 | 430 |
CC-TFB811 | FIM Bridge Interface Module | 24 VDC | 100x150x40 | 415 |
Frequently Asked Questions (FAQs)
Q1: What type of signals can the MC-PSTX03 module process?
A1: The MC-PSTX03 can handle both analog and digital signals depending on the configuration, making it versatile for a wide range of applications.
Q2: Is the module hot-swappable?
A2: Yes, the module supports hot-swapping, allowing for replacement without shutting down the entire system.
Q3: Can the MC-PSTX03 be used with non-Honeywell systems?
A3: While it is optimized for Honeywell systems, integration with third-party systems is limited due to proprietary protocols.
Q4: How do I perform diagnostics on this module?
A4: Diagnostic data can be accessed via the Honeywell Experion configuration tools, providing real-time fault and performance monitoring.
Q5: What is the average lifespan of this module?
A5: Under normal operating conditions, the module has an expected lifespan of over 10 years with minimal maintenance.
Q6: Does this module require external shielding?
A6: It is recommended to use shielded cables for field wiring to minimize electromagnetic interference, especially in high-noise industrial environments.
Honeywell MC-PSTX03 51304516-250 Smart Transmitter Interface Processor
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
51304516-250, Honeywell, Honeywell MC-PSTX03 51304516-250, MC-PSTX03, Smart Transmitter Interface Processor