Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Honeywell MU-TAIH12 51304337-100
Product Introduction
The Honeywell MU-TAIH12 51304337-100 is a high-performance Analog Input Module engineered for industrial automation systems within the Honeywell TDC 3000 and Experion Process Knowledge System (PKS) platforms. Designed to deliver superior accuracy, reliability, and compatibility, the MU-TAIH12 module facilitates the acquisition and conversion of analog signals from field instruments into digital data for process control and monitoring.
This module supports up to 16 differential analog input channels, enabling seamless integration of multiple analog devices such as temperature sensors, pressure transmitters, and flow meters. Built to meet stringent industrial standards, the MU-TAIH12 ensures stable signal acquisition even under harsh environmental conditions, making it a preferred choice for critical process applications in industries such as oil & gas, petrochemicals, pharmaceuticals, and power generation.
With its compact design, robust construction, and advanced diagnostics, the MU-TAIH12 enhances overall system uptime and facilitates efficient field maintenance and configuration.
Product Advantages
-
High-Density Channel Design: Supports up to 16 analog inputs per module, reducing system footprint and wiring complexity.
-
Advanced Signal Filtering: Incorporates high-precision filtering and noise reduction for stable and accurate signal conversion.
-
Seamless Integration: Fully compatible with Honeywell’s TDC 3000 and Experion PKS systems for plug-and-play installation.
-
Robust Reliability: Industrial-grade construction offers superior performance in high-vibration, high-temperature, or high-moisture environments.
-
Easy Maintenance: Features advanced diagnostics and status indicators for efficient troubleshooting and minimal downtime.
-
Hot Swappable: Allows for online replacement without system shutdown, ensuring operational continuity.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | MU-TAIH12 |
Part Number | 51304337-100 |
Input Channels | 16 Analog Inputs |
Input Signal Range | 0–20 mA / 4–20 mA / 1–5 V / 0–10 V |
Input Type | Differential |
Resolution | 16-bit |
Accuracy | ±0.1% of full scale |
Isolation | 1500 VDC channel-to-bus |
Voltage Requirement | 24 VDC nominal |
Power Consumption | < 5 W |
Module Type | Analog Input Module |
Operating Temperature Range | -20°C to +60°C |
Storage Temperature Range | -40°C to +85°C |
Relative Humidity | 5%–95% non-condensing |
Dimensions | 120 x 80 x 50 mm |
Weight | 0.55 kg |
Mounting | DIN rail or panel-mounted |
Certifications | CE, UL, CSA, FM Class I Div 2 |
Applications
-
Oil & Gas Facilities: For accurate real-time monitoring of pressure and temperature in upstream and downstream operations.
-
Chemical and Petrochemical Plants: For analog data acquisition from process sensors in hazardous environments.
-
Power Generation: Utilized in turbine and boiler control for precise temperature and pressure feedback.
-
Pharmaceutical Manufacturing: Assures strict process control and validation via reliable analog data capture.
-
Water and Wastewater Treatment: For flow and pH monitoring and control.
-
Food and Beverage Industry: Used in process control for temperature and fluid level measurement.
Compatible Models
The MU-TAIH12 51304337-100 module is typically used in conjunction with the following Honeywell systems and components:
-
MU-TDOD12 – Digital Output Module
-
MU-TLPA02 – Logic Power Adapter
-
MU-TAMR03 – Analog Multiplexer
-
MU-TAOX12 – Analog Output Module
-
MU-TDID12 – Digital Input Module
-
MU-PDIO02 – Power Distribution Module
-
MU-PDIS12 – Digital Interface Slave
These modules work together to provide a complete distributed control system for demanding process applications.
Installation Instructions
-
Preparation: Ensure that the system is powered down or that the module is being installed in a hot-swappable slot with the appropriate safety precautions in place.
-
Mounting: Install the MU-TAIH12 module onto a DIN rail or directly to the panel using mounting screws. Ensure proper alignment with system backplane connectors.
-
Wiring: Connect input wires to the designated terminals on the terminal block. Follow Honeywell’s wiring guide to ensure correct polarity and grounding.
-
Configuration: Use the system configuration software (Experion PKS or equivalent) to define channel ranges and calibration parameters.
-
Testing: Power on the system and validate all input channels using test signals or live field devices. Confirm communication with the control system.
-
Documentation: Update the system documentation to reflect the new module installation, including channel mappings and configuration parameters.
6 Related Honeywell Models
Model Number | Description | Input Type | Channels | Dimensions (mm) | Weight (kg) | Voltage |
---|---|---|---|---|---|---|
MU-TDOD12 | Digital Output Module | Digital | 16 | 50 x 130 x 180 | 0.5 | 24 VDC |
MU-TLPA02 | Logic Power Adapter | Power Adapter | – | 50 x 130 x 180 | 0.4 | 24 VDC |
MU-TAMR03 | Analog Multiplexer | Analog | 8 | 50 x 130 x 180 | 0.45 | 24 VDC |
MU-TAOX12 | Analog Output Module | Analog Output | 8 | 50 x 130 x 180 | 0.5 | 24 VDC |
MU-TDID12 | Digital Input Module | Digital | 16 | 50 x 130 x 180 | 0.55 | 24 VDC |
MU-PDIO02 | Power Distribution I/O Module | Mixed I/O | – | 50 x 130 x 180 | 0.6 | 24 VDC |
8 Popular Honeywell Models
Model Number | Description | Type | Channels | Dimensions (mm) | Weight (kg) | Voltage |
---|---|---|---|---|---|---|
CC-TDIL01 | Digital Input Module | Digital Input | 16 | 60 x 130 x 200 | 0.58 | 24 VDC |
CC-TAOX01 | Analog Output Module | Analog Output | 8 | 60 x 130 x 200 | 0.52 | 24 VDC |
CC-PCF901 | Fieldbus Processor Module | Communication | – | 60 x 130 x 200 | 0.60 | 24 VDC |
CC-TDOR01 | Digital Output Module | Digital Output | 16 | 60 x 130 x 200 | 0.54 | 24 VDC |
CC-PAIN01 | Analog Input Module | Analog Input | 16 | 60 x 130 x 200 | 0.55 | 24 VDC |
CC-TDOB01 | Digital Output Module | Digital Output | 16 | 60 x 130 x 200 | 0.56 | 24 VDC |
CC-TDIL11 | Digital Input with HART | Digital Input | 16 | 60 x 130 x 200 | 0.59 | 24 VDC |
CC-TCF901 | ControlNet Fieldbus Module | Communication | – | 60 x 130 x 200 | 0.62 | 24 VDC |
Frequently Asked Questions (FAQs)
Q1: What is the primary function of the MU-TAIH12 module?
A1: The MU-TAIH12 is used to collect and digitize analog signals from field instruments such as pressure or temperature sensors and feed them into a Honeywell DCS system for monitoring and control.
Q2: How many input channels does the MU-TAIH12 support?
A2: It supports up to 16 independent analog input channels, making it ideal for high-density input applications.
Q3: Can the MU-TAIH12 handle different types of analog signals?
A3: Yes, it is compatible with current (0–20 mA, 4–20 mA) and voltage (1–5 V, 0–10 V) analog input signals, offering great flexibility.
Q4: Is this module hot-swappable?
A4: Yes, the MU-TAIH12 supports hot swapping, allowing for module replacement without shutting down the entire control system.
Q5: What systems are compatible with MU-TAIH12?
A5: It is compatible with Honeywell’s TDC 3000 and Experion PKS platforms, integrating seamlessly into both legacy and modern automation systems.
Q6: Does the module offer channel-to-channel isolation?
A6: No, while it provides isolation between the field and system side, it does not support individual channel-to-channel isolation.