Honeywell TC-ODD321 97067172 A01 Product Overview
The Honeywell TC-ODD321 97067172 A01 is a high-performance optical dust detector designed for accurate and reliable particulate matter monitoring in various industrial and commercial environments. This device is widely used in HVAC systems, cleanrooms, and manufacturing facilities to ensure air quality compliance and operational efficiency.
Product Advantages
- High Accuracy: Utilizes advanced optical sensing technology to detect fine dust particles with precision.
- Durable Construction: Built to withstand harsh industrial environments with robust materials.
- Easy Integration: Compatible with multiple control systems for seamless installation.
- Low Maintenance: Designed for long-term use with minimal calibration requirements.
- Wide Application Range: Suitable for diverse industries, including pharmaceuticals, food processing, and electronics manufacturing.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | TC-ODD321 97067172 A01 |
Dimensions | 35 x 140x 145 mm |
Weight | 0.6kg |
Operating Voltage | 24 VDC (±10%) |
Current Consumption | 50 mA |
Detection Range | 0.1 μm to 10 μm |
Output Signal | 4-20 mA / 0-10 VDC |
Operating Temperature | -10°C to +50°C |
Humidity Range | 0% to 95% RH (non-condensing) |
Enclosure Rating | IP65 |
Applications
- HVAC Systems: Monitors air quality in ventilation systems.
- Cleanrooms: Ensures particulate levels meet industry standards.
- Industrial Manufacturing: Detects dust in production areas.
- Pharmaceuticals: Maintains sterile environments.
- Food Processing: Prevents contamination in sensitive zones.
Compatible Models for Integration
The TC-ODD321 can be paired with the following Honeywell devices for enhanced functionality:
- Honeywell T7512M1006 – Programmable thermostat.
- Honeywell HPA300 – Air purifier.
- Honeywell XNX Universal Transmitter – Gas detection system.
Installation Instructions
- Mounting: Secure the device on a flat surface using provided screws.
- Wiring: Connect the 24 VDC power supply and output signals as per the wiring diagram.
- Calibration: Perform initial calibration using a reference dust source.
- Testing: Verify functionality by introducing a test particulate sample.
- Maintenance: Clean the optical sensor quarterly for optimal performance.
Recommended Similar Models (Same Series)
Model | Dimensions | Weight | Voltage | Detection Range | Output |
---|---|---|---|---|---|
TC-ODD322 | 125 mm × 85 mm × 50 mm | 400 g | 24 VDC | 0.1 μm – 15 μm | 4-20 mA / 0-5 VDC |
TC-ODD323 | 130 mm × 90 mm × 55 mm | 420 g | 12-24 VDC | 0.05 μm – 20 μm | RS-485 Modbus |
TC-ODD324 | 110 mm × 75 mm × 40 mm | 320 g | 24 VDC | 0.2 μm – 12 μm | 0-10 VDC |
TC-ODD325 | 140 mm × 95 mm × 60 mm | 450 g | 24 VDC | 0.1 μm – 25 μm | 4-20 mA |
TC-ODD326 | 115 mm × 80 mm × 45 mm | 360 g | 12 VDC | 0.3 μm – 18 μm | 0-5 VDC |
TC-ODD327 | 135 mm × 85 mm × 50 mm | 380 g | 24 VDC | 0.1 μm – 30 μm | 4-20 mA / RS-485 |
Top 8 Popular Honeywell Models (Other Categories)
Model | Type | Dimensions | Weight | Voltage | Key Feature |
---|---|---|---|---|---|
Honeywell T6 Pro | Smart Thermostat | 86 mm × 86 mm × 25 mm | 200 g | 24 VAC | Wi-Fi Enabled |
Honeywell 5800PIR-RES | Motion Sensor | 90 mm × 65 mm × 40 mm | 150 g | 9 VDC | Wireless Detection |
Honeywell XC70 | Gas Detector | 180 mm × 140 mm × 80 mm | 1.2 kg | 24 VDC | Multi-Gas Detection |
Honeywell HWF3200 | Air Purifier | 400 mm × 250 mm × 400 mm | 8 kg | 220 VAC | HEPA Filtration |
Honeywell VX2 | Vibration Sensor | 50 mm × 50 mm × 30 mm | 120 g | 12-24 VDC | Industrial Grade |
Honeywell S8610U | Intermittent Pilot Module | 100 mm × 70 mm × 50 mm | 300 g | 24 VAC | Flame Safeguard |
Honeywell 900EV | Zone Valve | 120 mm × 80 mm × 60 mm | 500 g | 24 VAC | Hydronic Heating |
Honeywell RTH6500WF | Programmable Thermostat | 85 mm × 85 mm × 20 mm | 180 g | 24 VAC | Touchscreen Display |
FAQ (Frequently Asked Questions)
Q1: What is the lifespan of the TC-ODD321 sensor?
A1: With proper maintenance, the sensor can last up to 5-7 years under normal operating conditions.
Q2: Can this detector be used in explosive environments?
A2: No, the TC-ODD321 is not rated for explosive atmospheres. Use Honeywell’s intrinsically safe models for such applications.
Q3: How often should calibration be performed?
A3: Calibration is recommended every 12 months or after exposure to extreme conditions.
Q4: Is the output signal adjustable?
A4: Yes, the 4-20 mA or 0-10 VDC output can be configured via internal dip switches.
Q5: What is the response time of the detector?
A5: The typical response time is less than 2 seconds for particulate detection.
Q6: Can the device operate in high-humidity environments?
A6: Yes, it supports up to 95% RH (non-condensing). For condensing environments, additional protection is needed.
Honeywell TC-ODD321 97067172 A01 DC Output Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |