Schneider TSXCTY2C Detailed Product Overview
Product Introduction
The Schneider Electric TSXCTY2C is a high-performance communication module designed for use within the Modicon Premium automation platform. Specifically developed to ensure seamless data exchange and network integration, this module plays a pivotal role in industrial automation environments. The TSXCTY2C supports a variety of communication protocols, ensuring robust and reliable data transmission between controllers, field devices, and supervisory systems.
Engineered with Schneider Electric’s renowned commitment to quality and durability, the TSXCTY2C enables manufacturers and system integrators to establish high-speed, efficient networks that facilitate real-time control and monitoring. Its compact design allows easy installation into control cabinets, making it a preferred choice for space-constrained applications.
With global recognition for its reliability, the TSXCTY2C continues to be integral to smart manufacturing solutions, contributing to reduced downtime and optimized operational efficiency.
Product Advantages
-
High Reliability: Built to perform under demanding industrial conditions, ensuring continuous operation even in harsh environments.
-
Seamless Integration: Compatible with the Modicon Premium PLC series, allowing for straightforward integration into existing automation systems.
-
Flexible Communication: Supports multiple protocols for versatile application across different industries.
-
Compact Design: Space-saving footprint makes it ideal for installations with limited space.
-
Enhanced Performance: Fast data processing speeds ensure timely communication and control.
-
Robust Construction: Durable housing protects the internal circuitry, prolonging the module’s service life.
Technical Specifications
Specification | Details |
---|---|
Product Type | Communication Module |
Model Number | TSXCTY2C |
Compatibility | Modicon Premium PLC |
Supported Protocols | Serial Communication (RS485/RS232) |
Power Supply Voltage | 24 V DC |
Power Consumption | 3 W |
Dimensions | 55 ×180 × 260 mm |
Weight | 0.34 kg |
Operating Temperature | 0°C to 60°C |
Storage Temperature | -40°C to 85°C |
Relative Humidity | 5% to 95% non-condensing |
Mounting | DIN Rail |
Communication Speed | Up to 115.2 Kbps |
Certification | CE, UL, CSA |
Protection Class | IP20 |
Material | High-Grade Industrial Plastic |
Product Applications
-
Manufacturing Automation: Facilitates high-speed communication between PLCs and HMIs for real-time monitoring and control.
-
Process Control: Essential in industries such as oil and gas, chemical processing, and pharmaceuticals for reliable data exchange.
-
Material Handling Systems: Integrates with conveyor systems and automated warehouses for improved efficiency.
-
Energy Management Systems: Supports data collection and distribution in smart grids and energy monitoring solutions.
-
Building Automation: Enables communication between controllers for HVAC, lighting, and security systems.
-
Water Treatment Facilities: Assists in maintaining control over pumps, valves, and monitoring equipment.
Compatible Models
-
Modicon Premium TSX PLC Series
-
TSX57 Series CPU Modules
-
TSXDMZ28D5
-
TSXP573634M
-
TSXP57453M
-
TSXDSY16R5
-
TSXETY4103 (Ethernet communication module)
Installation Instructions
-
Preparation:
Ensure that the power supply to the control cabinet is switched off before installation to prevent electrical shock or damage to the module. -
Mounting:
Use the DIN rail mounting method. Align the module’s mounting clip with the DIN rail and snap it firmly into place. -
Wiring:
Connect the power supply cables to the designated terminals. Use shielded cables for communication ports to reduce interference. -
Communication Setup:
Configure the communication parameters using the PLC programming software (such as Unity Pro or EcoStruxure Control Expert). -
Testing:
Power on the system and verify communication status using diagnostic LEDs on the module. -
Final Checks:
Ensure all connections are secure and settings are correctly configured before putting the system into operation.
Related Models (Same Series or Similar)
Model Number | Description | Voltage | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|
TSXCTY4C | Communication Module RS485/RS232 | 24 V DC | 100 x 40 x 115 | 0.36 |
TSXETY4103 | Ethernet Communication Module | 24 V DC | 130 x 45 x 130 | 0.40 |
TSXP57103M | Premium CPU Module | 24 V DC | 125 x 45 x 130 | 0.38 |
TSXDMZ28D5 | Digital Mixed I/O Module | 24 V DC | 140 x 50 x 130 | 0.42 |
TSXDSY16R5 | Digital Output Module | 24 V DC | 140 x 50 x 130 | 0.44 |
TSXP57453M | High-Performance CPU Module | 24 V DC | 140 x 50 x 140 | 0.46 |
Popular Schneider Models
Model Number | Description | Voltage | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|
BMXP342020 | Modicon M340 CPU Module | 24 V DC | 150 x 55 x 140 | 0.45 |
BMENOC0301 | Communication Module Ethernet | 24 V DC | 160 x 60 x 140 | 0.48 |
ATV320U22N4B | Altivar 320 Drive | 380-500 V | 143 x 72 x 152 | 1.60 |
LC1D12BD | TeSys Contactor | 24 V DC | 90 x 45 x 95 | 0.32 |
NSX100F TM100D | Compact Circuit Breaker | 100-240 V | 138 x 105 x 80 | 1.45 |
XB5AA31 | Pushbutton Head | 24 V DC | 30 x 30 x 45 | 0.05 |
HMISTU655 | Touchscreen HMI | 24 V DC | 206 x 156 x 38 | 0.65 |
SM6-24 | Medium Voltage Switchgear | 230-400 V | 750 x 650 x 1800 | 90.00 |
FAQs (Q&A Format)
Q1: What is the primary function of the Schneider TSXCTY2C module?
A1: The TSXCTY2C is primarily designed to facilitate serial communication between Modicon Premium PLCs and peripheral devices, ensuring reliable data exchange within industrial automation systems.
Q2: Can the TSXCTY2C module be used in outdoor environments?
A2: No, the TSXCTY2C is intended for indoor use within control cabinets. It has an IP20 protection class and requires a controlled environment to function optimally.
Q3: How do I configure the TSXCTY2C communication settings?
A3: Configuration is performed using Schneider’s PLC programming software such as EcoStruxure Control Expert (formerly Unity Pro), where you can set baud rates, parity, stop bits, and other parameters.
Q4: Does the TSXCTY2C support firmware updates?
A4: Yes, Schneider Electric provides firmware updates for its communication modules to enhance performance and security. Updates can be applied through the configuration software.
Q5: What maintenance is required for the TSXCTY2C?
A5: The module requires minimal maintenance. Regular checks for secure wiring connections, clean environments, and periodic diagnostic tests are recommended.
Q6: Is the TSXCTY2C compatible with third-party devices?
A6: Yes, as long as the third-party devices support compatible serial communication standards (RS485/RS232), integration is possible with correct configuration.
Schneider TSXCTY2C Measurement and counter module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |