okogawa A2SAM105 Product Overview
The Yokogawa A2SAM105 is a high-performance signal conditioner designed for industrial automation and process control applications. It provides reliable signal conversion, isolation, and amplification, ensuring accurate data transmission in harsh environments.
This product is widely used in industries such as oil & gas, chemical, power generation, and water treatment, where signal integrity and noise immunity are critical.
Product Advantages
- High Accuracy & Stability
The A2SAM105 delivers precise signal conditioning with minimal drift, ensuring long-term reliability. - Robust Isolation
Features galvanic isolation to protect sensitive equipment from ground loops and electrical noise. - Wide Input/Output Range
Supports various signal types (mA, mV, V, thermocouple, RTD) for flexible integration. - Compact & Durable Design
Built to withstand industrial environments with high resistance to vibration and temperature fluctuations. - Easy Configuration
User-friendly setup with DIP switches or software configuration options. - Compliance with Industry Standards
Meets international safety and EMC standards for industrial applications.
Technical Specifications
Parameter | Specification |
---|---|
Input Signal | 4-20 mA, 0-10 V, thermocouple (J, K, T, etc.), RTD (Pt100) |
Output Signal | 4-20 mA, 0-10 V, pulse, relay |
Isolation | 1500 V AC (input/output/power) |
Accuracy | ±0.1% of span |
Operating Temperature | -20°C to +60°C |
Power Supply | 24 V DC (10-30 V DC range) |
Dimensions (W×H×D) | 130 x 12.8 x 40 mm |
Weight | 0.1 kg |
Mounting | DIN rail or panel mount |
Certifications | CE, UL, IEC 61010, IEC 61326 |
Applications
- Process Control Systems – Signal conditioning for PLCs and DCS.
- Power Plants – Monitoring and control of critical parameters.
- Oil & Gas – Isolation and conversion of field sensor signals.
- Water & Wastewater – Reliable signal transmission in corrosive environments.
- Manufacturing Automation – Integration with motor controls and robotics.
Compatible & Recommended Accessories
Model | Description |
---|---|
A2SAM101 | Basic signal conditioner (4-20 mA input/output) |
A2SAM102 | Dual-channel isolator |
A2SAM103 | Thermocouple/RTD signal converter |
A2SAM104 | Frequency/pulse converter |
A2SAM106 | High-density signal conditioner |
A2SAM107 | Advanced communication interface model |
Installation Instructions
- Mounting – Secure the unit on a DIN rail or panel using the provided clips.
- Wiring – Connect input/output/power terminals as per the wiring diagram.
- Configuration – Set DIP switches or use software for desired signal conversion.
- Testing – Verify signal accuracy before full operation.
- Maintenance – Periodically check for dust accumulation and secure connections.
Recommended Related Models (Same Series)
Model | Input | Output | Isolation | Dimensions (mm) | Weight | Voltage |
---|---|---|---|---|---|---|
A2SAM101 | 4-20 mA | 4-20 mA | 1500 V AC | 22.5×100×115 | 180 g | 24 V DC |
A2SAM102 | Dual 4-20 mA | Dual 4-20 mA | 1500 V AC | 45×100×115 | 250 g | 24 V DC |
A2SAM103 | Thermocouple | 4-20 mA | 1500 V AC | 22.5×100×115 | 190 g | 24 V DC |
A2SAM104 | Frequency | 4-20 mA | 1500 V AC | 22.5×100×115 | 200 g | 24 V DC |
A2SAM106 | Multi-signal | Multi-signal | 1500 V AC | 45×100×115 | 300 g | 24 V DC |
A2SAM107 | RS-485 Modbus | 4-20 mA | 1500 V AC | 22.5×100×115 | 210 g | 24 V DC |
Top 8 Popular Yokogawa Models
Model | Type | Input | Output | Dimensions (mm) | Weight | Voltage |
---|---|---|---|---|---|---|
YTA510 | Temperature Transmitter | RTD/Thermocouple | 4-20 mA | 44×92×108 | 300 g | 12-30 V DC |
EJX110A | Differential Pressure Transmitter | Pressure | 4-20 mA | 96×96×155 | 1.5 kg | 10.5-45 V DC |
AXF050G | Magnetic Flowmeter | Liquid flow | 4-20 mA, pulse | 150×150×200 | 3.5 kg | 100-240 V AC |
UTAdvanced | Ultrasonic Level Meter | Level | 4-20 mA, relay | 185×135×120 | 1.8 kg | 24 V DC |
UM33A | pH/ORP Sensor | pH/ORP | 4-20 mA | 90×140×60 | 500 g | 24 V DC |
FV101 | Vortex Flowmeter | Gas/Liquid flow | 4-20 mA | 80×80×150 | 2 kg | 24 V DC |
DPharp EJA | Pressure Transmitter | Pressure | 4-20 mA | 104×104×132 | 1.2 kg | 10.5-42 V DC |
SMARTPH | Smart Pressure Gauge | Pressure | 4-20 mA | 50×50×50 | 200 g | 24 V DC |
FAQ (Frequently Asked Questions)
Q1: What is the maximum isolation voltage of the A2SAM105?
A1: It provides 1500 V AC isolation between input, output, and power supply.
Q2: Can the A2SAM105 handle RTD inputs?
A2: Yes, it supports RTD (Pt100) inputs along with thermocouples and standard analog signals.
Q3: What is the operating temperature range?
A3: It operates reliably between -20°C and +60°C.
Q4: Is the A2SAM105 compatible with Modbus communication?
A4: No, for Modbus support, consider the A2SAM107 model.
Q5: How is the device powered?
A5: It requires a 24 V DC power supply (10-30 V DC range).
Q6: Can it be mounted on a DIN rail?
A6: Yes, it supports both DIN rail and panel mounting.
Yokogawa A2SAM105 Current Input/Voltage Input Adaptor
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |