Product Introduction:
The Yokogawa AAI135-S00 Analog Input Module is a high-performance module designed for use in industrial control systems. It is a part of Yokogawa’s extensive offering of fieldbus-compatible modules used in various process control applications. This module provides analog input capabilities with high accuracy and reliability, making it ideal for a wide range of automation applications.
The AAI135-S00 module is widely used in industries like oil and gas, chemical processing, and power generation, where it interfaces with various field devices to acquire data for monitoring and control. Its compact design, ease of installation, and versatility make it a preferred choice for enhancing the reliability and flexibility of industrial automation systems.
Technical Specifications:
Parameter | Specification |
---|---|
Model | AAI135-S00 |
Input Channels | 8 channels |
Input Range | 0 to 10 VDC, 4 to 20 mA |
Resolution | 16 bits |
Accuracy | ±0.1% of FS |
Power Supply | 24 VDC (±10%) |
Dimensions | 107.5 × 32.8 × 130 mm |
Weight | 0.3 kg |
Operating Temperature | -20 to 60°C |
Mounting | DIN Rail or Panel Mounting |
Communication | Fieldbus (Modbus, Profibus) |
Applications:
The Yokogawa AAI135-S00 Analog Input Module is designed to be used in applications requiring high-precision analog data acquisition. Typical applications include:
-
Process Control: For precise measurement and monitoring of various process parameters such as temperature, pressure, and flow rate.
-
Data Logging: Used in industries to capture and record data for later analysis.
-
Automation Systems: Integrates with distributed control systems (DCS) and programmable logic controllers (PLC) for seamless automation.
-
Energy Management: Helps in monitoring energy usage in facilities, ensuring optimized energy consumption.
-
Chemical & Pharmaceutical: Critical in maintaining strict process control in industries that demand high standards, such as pharmaceuticals.
Advantages:
-
High Accuracy: With a 16-bit resolution and ±0.1% FS accuracy, it ensures reliable data measurement, enhancing overall system performance.
-
Compact Design: Its small form factor of 107.5 × 32.8 × 130 mm allows for easy integration into space-constrained control cabinets or panels.
-
Wide Input Range: Supports both 0-10 VDC and 4-20 mA input signals, making it adaptable to various industrial field devices.
-
Easy Integration: The module’s compatibility with fieldbus communication protocols, such as Modbus and Profibus, ensures smooth integration into existing systems.
-
Rugged and Reliable: Designed to operate in challenging environments with a wide operating temperature range of -20 to 60°C, ensuring consistent performance in extreme conditions.
Related Models:
Here are five related models from the same series or with similar functionality:
Model | Description | Key Features |
---|---|---|
AAI135-S01 | 8-channel analog input module | Similar to AAI135-S00, but with enhanced filtering capabilities for noisy environments. |
AAI135-S02 | 4-channel analog input module | Compact version with lower channel count but same high accuracy. |
AAI141-S00 | 16-channel analog input module | Expanded channel count for large-scale automation systems. |
AAI145-S00 | High-speed analog input module | Faster data acquisition for high-frequency measurement applications. |
AAI100-S00 | Analog input with integrated signal conditioning | Offers signal conditioning capabilities for specific sensor types. |
Popular Yokogawa Models:
Here are five popular models from Yokogawa, which are widely used in industrial automation:
Model | Description | Key Features |
---|---|---|
F3RP70-A01 | Temperature controller | High-precision temperature control with dual outputs. |
AIP500-S00 | Intelligent pressure module | Measures pressure with high sensitivity and reliability. |
EJA210E | Differential pressure transmitter | Measures differential pressure for various applications, including flow and level monitoring. |
EJX910A | Transmitter with integrated HART communication | Advanced diagnostics and remote communication capabilities. |
FLXA202 | pH/ORP transmitter | Accurate pH/ORP measurement for water treatment processes. |
Product Installation Instructions:
-
Prepare the Installation Site: Ensure the installation environment meets the temperature, humidity, and power supply specifications.
-
Mounting the Module: The module can be mounted on a DIN rail or directly on a panel. Ensure that it is securely fixed to avoid vibration during operation.
-
Wiring: Connect the input signals from the field devices (e.g., sensors) to the corresponding terminals on the module. Ensure that the wiring is correct and secure.
-
Power Supply: Connect the module to a 24V DC power supply, ensuring the polarity is correct to avoid damage.
-
Fieldbus Communication: Connect the module to the fieldbus network (e.g., Modbus or Profibus) for communication with the controller.
-
Verification: Once the wiring is complete, power on the system and check the data output to ensure proper operation.
Frequently Asked Questions (FAQs):
Q1: What is the input signal range for the AAI135-S00 module?
A1: The input signal range is 0-10 VDC and 4-20 mA.
Q2: What is the power supply requirement for this module?
A2: The module requires a 24 VDC power supply with ±10% tolerance.
Q3: How many input channels does the AAI135-S00 module support?
A3: The module supports 8 input channels.
Q4: What is the accuracy of the module?
A4: The accuracy of the module is ±0.1% of full scale (FS).
Q5: Can this module be used in outdoor environments?
A5: The module is designed for indoor use, but it can operate in a wide temperature range of -20°C to 60°C.
Q6: How do I integrate this module into an existing fieldbus system?
A6: The module supports Modbus and Profibus communication protocols, making integration into existing systems straightforward.
Q7: Is this module suitable for hazardous environments?
A7: The AAI135-S00 is not intrinsically safe for hazardous areas. For such environments, a different module may be required.
Q8: What is the weight of the AAI135-S00 module?
A8: The weight of the module is 0.3 kg.
Q9: How can I configure the module?
A9: Configuration can be done through the fieldbus network interface or by using a dedicated configuration tool.
Q10: What is the warranty period for the AAI135-S00 module?
A10: The warranty period typically lasts for 1 year.
Yokogawa AAI135-S00 Analog Input Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |