Yokogawa AAI141-H50 Product Introduction
The Yokogawa AAI141-H50 is a high-performance analog input module designed for industrial automation and control systems. It is part of Yokogawa’s extensive lineup of I/O modules, known for their reliability, precision, and durability in harsh environments. The AAI141-H50 is widely used in process control, manufacturing, and energy management systems, providing accurate analog signal acquisition for critical applications.
This module supports multiple input channels, offering flexibility and scalability for complex systems. Its robust design ensures long-term stability and minimal maintenance, making it a preferred choice for industries requiring high accuracy and reliability.
Product Advantages
- High Accuracy: The AAI141-H50 delivers precise analog signal conversion with minimal error, ensuring reliable data acquisition.
- Robust Construction: Built to withstand harsh industrial environments, including extreme temperatures and electromagnetic interference.
- Multi-Channel Support: Allows for simultaneous processing of multiple analog inputs, reducing the need for additional modules.
- Easy Integration: Compatible with Yokogawa’s control systems and other industrial automation platforms.
- Low Maintenance: Designed for long-term operation with minimal downtime, reducing total cost of ownership.
- Scalability: Can be easily expanded or integrated into larger systems, providing flexibility for future upgrades.
Technical Parameters
Parameter | Specification |
---|---|
Model | Yokogawa AAI141-H50 |
Input Channels | 16 channels |
Input Signal Type | 4-20 mA, 0-20 mA, 1-5 V, 0-5 V, 0-10 V |
Accuracy | ±0.1% of full scale |
Resolution | 16-bit |
Sampling Rate | 10 ms per channel |
Isolation | Channel-to-channel and channel-to-ground |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +85°C |
Humidity Range | 10% to 90% RH (non-condensing) |
Voltage Supply | 24 VDC (±10%) |
Power Consumption | 5 W max |
Dimensions | 107.5×32.8×130 mm |
Weight | 0.2 kg |
Communication Interface | Backplane communication (vendor-specific) |
Certifications | CE, UL, IEC 61010 |
Applications
The AAI141-H50 is suitable for a wide range of industrial applications, including:
- Process Control: Monitoring and controlling analog signals in chemical, oil, and gas industries.
- Manufacturing Automation: Integrating with PLCs and DCS for real-time data acquisition.
- Energy Management: Measuring and analyzing power consumption in smart grids.
- Water Treatment: Monitoring flow rates, pressure, and chemical levels in treatment plants.
- HVAC Systems: Controlling temperature and humidity in large-scale facilities.
Compatible Products
The AAI141-H50 can be used alongside the following Yokogawa products:
- Yokogawa AAR145-S00: Analog output module for complementary signal control.
- Yokogawa ADM11B: Signal conditioner for enhanced signal processing.
- Yokogawa PLCs (e.g., FA-M3 series): For integrated control systems.
- Yokogawa DCS (e.g., CENTUM VP): For large-scale distributed control.
- Yokogawa SIS (ProSafe-RS): For safety instrumented systems.
Installation Instructions
- Pre-Installation Check: Ensure the power supply is turned off and the environment meets the module’s operating conditions.
- Mounting: Secure the module to a DIN rail or panel using the provided brackets.
- Wiring: Connect the analog input signals and power supply according to the wiring diagram. Ensure proper grounding.
- Configuration: Use Yokogawa’s configuration software to set up the input ranges and communication parameters.
- Testing: Power on the system and verify signal accuracy using a calibrated source.
- Final Inspection: Ensure all connections are secure and the module is functioning as expected.
Recommended Related Models (Same Series)
Model | Channels | Input Type | Accuracy | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
AAI143-H50 | 8 | 4-20 mA, 0-10 V | ±0.1% | 24 VDC | 120 x 130 x 60 | 450 g |
AAI142-H50 | 32 | 4-20 mA, 1-5 V | ±0.15% | 24 VDC | 150 x 130 x 60 | 600 g |
AAI145-H50 | 16 | Thermocouple, RTD | ±0.2% | 24 VDC | 120 x 130 x 60 | 500 g |
AAI146-H50 | 16 | 0-20 mA, 0-5 V | ±0.1% | 24 VDC | 120 x 130 x 60 | 500 g |
AAI147-H50 | 8 | 4-20 mA, 0-10 V | ±0.05% | 24 VDC | 120 x 130 x 60 | 450 g |
AAI148-H50 | 16 | 4-20 mA, 1-5 V | ±0.1% | 24 VDC | 120 x 130 x 60 | 500 g |
Recommended Popular Yokogawa Models
Model | Type | Key Parameters | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
AAR145-S00 | Analog Output Module | 16 channels, 4-20 mA, ±0.1% accuracy | 24 VDC | 120 x 130 x 60 | 500 g |
ADM11B | Signal Conditioner | 8 channels, 4-20 mA, ±0.05% accuracy | 24 VDC | 100 x 120 x 50 | 400 g |
FA-M3V10 | PLC Module | 32 I/O points, 24 VDC, 10 ms cycle time | 24 VDC | 150 x 140 x 70 | 800 g |
CENTUM VP | DCS Controller | Scalable, 1000+ I/O points, 24 VDC | 24 VDC | 200 x 200 x 100 | 2 kg |
ProSafe-RS | Safety System | SIL3 certified, 24 VDC, 16 channels | 24 VDC | 180 x 160 x 80 | 1.5 kg |
WT3000 | Power Analyzer | 0.1% accuracy, 3-phase, 600 V max | 100-240 VAC | 250 x 150 x 200 | 3 kg |
DX1000 | Data Acquisition | 64 channels, 24-bit resolution, 24 VDC | 24 VDC | 200 x 180 x 90 | 1.8 kg |
UM33A | Recorder | 12 channels, 0.1% accuracy, 24 VDC | 24 VDC | 220 x 160 x 100 | 2.2 kg |
FAQ (Q&A)
Q1: What is the maximum sampling rate of the AAI141-H50?
A1: The maximum sampling rate is 10 ms per channel.
Q2: Can the AAI141-H50 be used in hazardous environments?
A2: Yes, it is designed to operate in harsh industrial environments but may require additional enclosures for hazardous areas.
Q3: What communication protocols does the AAI141-H50 support?
A3: It supports backplane communication protocols specific to Yokogawa’s control systems.
Q4: Is the AAI141-H50 compatible with third-party PLCs?
A4: Compatibility depends on the PLC’s communication interface. Additional signal conditioners may be required.
Q5: What is the warranty period for the AAI141-H50?
A5: Yokogawa typically offers a 2-year warranty for this product.
Q6: How do I troubleshoot signal inaccuracies?
A6: Verify wiring, grounding, and input signal range settings. Use a calibrated source to test individual channels.