Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Yokogawa AAI143-S00 Product Overview
The Yokogawa AAI143-S00 is a high-performance analog input module designed for industrial automation and process control applications. It is part of Yokogawa’s extensive lineup of I/O modules, known for their reliability, precision, and robust construction. This module is widely used in industries such as oil & gas, chemical, power generation, and water treatment, where accurate signal acquisition is critical.
Product Advantages
- High Accuracy & Precision – Delivers reliable analog signal conversion with minimal error.
- Robust Design – Built to withstand harsh industrial environments, including resistance to vibration and EMI.
- Easy Integration – Compatible with Yokogawa’s control systems, ensuring seamless system expansion.
- Wide Input Range – Supports multiple signal types (e.g., 4-20mA, 0-10V) for versatile applications.
- Diagnostic Features – Includes self-diagnostics for quick troubleshooting and maintenance.
- Long-Term Stability – Ensures consistent performance over extended periods with minimal drift.
Technical Specifications
Parameter | Specification |
---|---|
Input Type | Analog (4-20mA, 0-10V, etc.) |
Channels | 16 single-ended / 8 differential |
Resolution | 16-bit |
Accuracy | ±0.1% of full scale |
Isolation | Channel-to-channel & field-to-system |
Operating Voltage | 24V DC (±10%) |
Power Consumption | 5W max |
Dimensions | 107.5 × 32.8 × 130 mm |
Weight | 0.3 kg |
Operating Temp. | -20°C to +60°C |
Humidity Range | 10% to 90% RH (non-condensing) |
Applications
- Process Control Systems – Monitoring and controlling industrial processes.
- Data Acquisition – High-speed and high-accuracy signal measurement.
- Power Plants – Integration into distributed control systems (DCS).
- Oil & Gas – Used in refineries and offshore platforms.
- Water Treatment – Monitoring flow, pressure, and chemical levels.
Compatible Models for Integration
The AAI143-S00 can be used alongside:
- Yokogawa AAI543-S00 (Analog Output Module)
- Yokogawa ADI143-S00 (Digital Input Module)
- Yokogawa AAX143-S00 (Temperature Input Module)
- Yokogawa CPU01 (Controller Unit)
- Yokogawa N-IOU01 (Network I/O Unit)
Installation Instructions
- Mounting – Secure the module on a DIN rail or panel using the provided screws.
- Wiring – Connect input signals according to the terminal assignments (refer to the manual).
- Power Connection – Ensure proper polarity when connecting the 24V DC supply.
- Grounding – Use a dedicated ground wire to minimize noise interference.
- Configuration – Set the DIP switches or software parameters as needed.
- Testing – Verify signal readings before full operation.
Recommended Similar/Related Models
Model | Type | Channels | Input/Output | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
AAI543-S00 | Analog Output Module | 8 | 4-20mA, 0-10V | 24V DC | 45 × 130 × 120 | 500g |
ADI143-S00 | Digital Input Module | 16 | 24V DC/AC | 24V DC | 45 × 130 × 120 | 450g |
AAX143-S00 | Temp. Input Module | 8 | RTD/Thermocouple | 24V DC | 45 × 130 × 120 | 480g |
AAI163-S00 | High-Speed Analog In | 32 | ±10V, 4-20mA | 24V DC | 45 × 130 × 120 | 520g |
AAO143-S00 | Analog Output Module | 16 | 4-20mA | 24V DC | 45 × 130 × 120 | 510g |
ADM143-S00 | Digital Mix Module | 16 DI/8 DO | 24V DC | 24V DC | 45 × 130 × 120 | 490g |
Popular Yokogawa Models (Other Series)
Model | Type | Key Parameters | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
EJX110A | Differential Pressure Transmitter | 0.04% accuracy, 4-20mA+HART | 10.5-42V DC | 110 × 150 × 85 | 2.5kg |
DYR200 | Digital Controller | 1/4 DIN, PID control, 4-20mA I/O | 100-240V AC | 96 × 96 × 100 | 600g |
UTAdvanced | Ultrasonic Flow Meter | 0.5% accuracy, 4-20mA/RS-485 | 24V DC | 200 × 150 × 80 | 1.8kg |
SMARTAX | pH/ORP Sensor | Glass-free, 2-wire, 4-20mA | 12-42V DC | 120 × 45 mm (dia.) | 300g |
FLEXA | Gas Analyzer | CO2, O2, NOx measurement, Modbus | 100-240V AC | 500 × 400 × 200 | 15kg |
CENTUM VP | DCS Controller | Redundant CPU, 10,000 I/O capacity | 24V DC | 800 × 600 × 200 | 25kg |
WT3000 | Power Analyzer | 0.1% accuracy, 3-phase measurement | 100-240V AC | 215 × 132 × 370 | 5kg |
IS8000 | Integrated Safety PLC | SIL3 certified, 128 I/O points | 24V DC | 200 × 150 × 80 | 1.2kg |
FAQ (Frequently Asked Questions)
Q1: What is the maximum sampling rate of the AAI143-S00?
A1: The module supports a sampling rate of up to 100 samples per second per channel.
Q2: Can the AAI143-S00 be used in hazardous areas?
A2: Yes, but it requires an additional intrinsic safety barrier for Zone 0/1 applications.
Q3: How do I troubleshoot a communication error with the module?
A3: Check the wiring, power supply, and ensure the DIP switches are correctly configured.
Q4: Is the AAI143-S00 compatible with third-party PLCs?
A4: It is optimized for Yokogawa systems but can interface via Modbus RTU or TCP/IP with adapters.
Q5: What is the expected lifespan of this module?
A5: Under normal conditions, it operates reliably for 10+ years with proper maintenance.
Q6: Can I hot-swap the AAI143-S00 during operation?
A6: No, hot-swapping is not recommended—always power down before installation/removal.
Yokogawa AAI143-s00 Analog Input Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |