Yokogawa AAI543-h50 Analog Output Module

Short Description:

📘 Product Overview – Yokogawa AAI543-H50 The Yokogawa AAI543-H50 is an advanced Analog Input Module used within the CENTUM CS 3000/VP control system, designed for precise and reliable analog signal……


  • Manufacturer: Yokogawa
  • Product Number: AAI543-h50
  • Product Type: Analog Output Module
  • Origin: Japan
  • Dimensions: 107.5 × 32.8 × 130 mm
  • Weight: 0.4 kg
  • Condition: New & In Stock
  • Payment Methods: T/T, PayPal, Western Union
  • Shipping Port: Xiamen, China
  • Lead Time: 1-3 Working Days
  • Warranty: One Year
  • Certificate: COO
  • Courier partners: DHL, UPS, TNT, FedEx and EMS.
8

Product Detail

Contact Us

Frequently FAQ

Real photos

Comment

Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat +8615980777398
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

📘 Product Overview – Yokogawa AAI543-H50

The Yokogawa AAI543-H50 is an advanced Analog Input Module used within the CENTUM CS 3000/VP control system, designed for precise and reliable analog signal acquisition. It is a high-performance 16-channel input card that supports 4-20 mA DC signals, commonly utilized in demanding industrial automation and process control environments.

The AAI543-H50 is engineered with high isolation and noise immunity, making it highly suitable for critical applications where signal integrity and system stability are essential. It also offers HART communication support, enabling enhanced diagnostic and monitoring capabilities.

Product Advantages

  • High-Density Analog Input: 16 channels in a single module for compact and efficient input handling.

  • HART Protocol Support: Enables advanced diagnostics and remote device configuration.

  • Excellent Accuracy: Superior signal resolution and low drift ensure reliable performance.

  • Robust Electrical Isolation: Channel-to-channel and channel-to-ground isolation protects the system from faults and noise.

  • Long-Term Reliability: Built with industrial-grade components for extended field operation.

  • Easy Integration: Seamlessly integrates into Yokogawa’s control systems with minimal configuration.

📊 Technical Specifications

Parameter Specification
Model AAI543-H50
Channels 16 Analog Input Channels
Input Signal Range 4–20 mA DC (with HART support)
Resolution 16-bit
Isolation Channel-to-Channel and Channel-to-Ground
Input Resistance 250 Ω
Power Supply Voltage 24 V DC (supplied from node)
Dimensions 107.5 × 32.8 × 130 mm
Weight 0.4 kg
Operating Temperature 0°C to 50°C
Storage Temperature -20°C to +70°C
Relative Humidity 5% to 95% (non-condensing)
Voltage Withstanding 1500 V AC (1 min)
Status Indication LEDs for module status
Certifications CE, CSA, FM, ATEX
Mounting Method Mounted on I/O base or node unit

🏭 Applications

  • Oil & Gas Processing Plants

  • Petrochemical Refineries

  • Pharmaceutical Manufacturing

  • Power Generation Facilities

  • Water & Wastewater Treatment Plants

  • Food & Beverage Automation Systems

This module plays a critical role in analog signal acquisition from transmitters, flow meters, level sensors, and other field devices requiring precise and reliable measurement input.

🔗 Compatible Models / Modules

The AAI543-H50 is typically used in combination with the following Yokogawa components for optimal functionality:

  • Yokogawa ATB150 – Terminal block

  • Yokogawa ALR121 – Base plate for mounting

  • Yokogawa FCS (Field Control Station) – Control unit integration

  • Yokogawa HART multiplexer – For advanced HART communication routing

  • Yokogawa AAI143-H50 – Analog input module (non-HART)

  • Yokogawa AAI841-H50 – Analog input module for temperature inputs

🧰 Installation Instructions

  1. Power Down the control system before installing the module to prevent damage or injury.

  2. Mount the AAI543-H50 onto the dedicated terminal base (e.g., ATB150) ensuring correct orientation and firm connection.

  3. Connect Analog Inputs using shielded cables to minimize electrical noise. Terminate the signal wires according to the wiring diagram provided by Yokogawa.

  4. Ground Properly to ensure electrical safety and to avoid signal interference.

  5. Configure the Module using the engineering tool of the CENTUM system. Assign channels and enable HART communication if required.

  6. Perform Diagnostics and Validation after installation to ensure all channels are correctly receiving input and functioning.

  7. Document all Wiring and Configuration settings for future reference or maintenance.

🔁 6 Related or Similar Models

Model Description
AAI143-H50 16-channel AI module without HART support
AAI841-H50 AI module designed for thermocouple inputs
ADV151-P00 8-channel voltage analog input module
AAI543-S50 Safety-rated version of AAI543
AAI135-H50 8-channel high-speed analog input module
AAI141-H50 16-channel AI module, cost-optimized

8 Popular Yokogawa Models (With Key Parameters)

Model Channels Signal Type Dimensions (mm) Weight (kg) Voltage
AAI543-H50 16 4–20 mA (HART) 27.4 x 130 x 176 0.25 24 V DC
AAI143-H50 16 4–20 mA 27.4 x 130 x 176 0.23 24 V DC
AAI841-H50 8 TC/RTD 27.4 x 130 x 176 0.26 24 V DC
AAI135-H50 8 4–20 mA 27.4 x 130 x 176 0.22 24 V DC
ADV151-P00 8 Voltage Input 27.4 x 130 x 176 0.24 24 V DC
ADV151-H50 8 4–20 mA 27.4 x 130 x 176 0.25 24 V DC
AAI141-H50 16 4–20 mA 27.4 x 130 x 176 0.23 24 V DC
AAI543-S50 16 4–20 mA (Safe) 27.4 x 130 x 176 0.27 24 V DC

Frequently Asked Questions (FAQ)

Q1: What is the main difference between AAI543-H50 and AAI143-H50?
A1: The AAI543-H50 supports HART communication, allowing for enhanced field device diagnostics and configuration, whereas the AAI143-H50 does not support HART.

Q2: Can I use the AAI543-H50 with non-HART devices?
A2: Yes, it fully supports standard 4–20 mA signals. HART functionality is optional and only utilized when connected to HART-capable field devices.

Q3: What maintenance is required for the AAI543-H50?
A3: It requires minimal maintenance. Periodic validation of input channels and checking terminal tightness is recommended. Firmware updates may be needed occasionally.

Q4: How many modules can be installed in a single rack?
A4: This depends on the system configuration and available power. Typically, multiple AAI543-H50 modules can be installed, provided the rack has sufficient power and I/O capacity.

Q5: Is the AAI543-H50 suitable for safety instrumented systems (SIS)?
A5: No, the standard AAI543-H50 is not certified for use in SIS. Use the AAI543-S50 or other safety-rated modules for such applications.

Q6: Does this module support hot swapping?
A6: No, hot swapping is not supported. Always power down the system before removing or inserting the module to avoid damage.

Yokogawa AAI543-h50 Analog Output Module

Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat +8615980777398
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China
Does this product come with a warranty?
Yes, we offer a 1-year warranty and support returns and exchanges to fully protect your rights.
How to verify products before purchase?
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation.
How long does shipping take?
Shipping times vary by location. With our 16 global warehouses, we strive for fast delivery. Contact us for an estimated delivery time.
What is the minimum order quantity (MOQ)?
The MOQ is usually one unit. For bulk orders, please contact us for discounts and pricing details.
Can I get discounts for bulk purchases?
Yes, we offer competitive pricing for bulk purchases. Contact our sales team for a custom quote.
What payment methods do you accept for wholesale orders?
We accept various methods, including bank transfers (T/T), letters of credit (L/C), and more upon agreement.
Can I purchase different quantities of a product?
Yes, we offer flexible ordering options, whether you need a single unit or a large batch.
Are there discounts for new wholesale customers?
We occasionally offer promotional discounts for new wholesale customers. Contact us for current offers.
How can I ensure compatibility with my existing systems?
If unsure, please provide your system details, and our support team will verify compatibility before purchase.
Can I return products if they don’t meet my requirements?
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Return shipping costs are the buyer's responsibility.
Do you provide technical support or installation services?
Yes, we offer technical support for installation, configuration, and troubleshooting.

Yokogawa AAI543-h50 Analog Output Module

Yokogawa AAI543-h50 Analog Output Module

Yokogawa AAI543-h50 Analog Output Module

Yokogawa AAI543-h50 Analog Output Module

Comment
Please leave your comments, we value your opinions very much.
*
*
*

Hot Tags


Prev or Next


Send Us An Inquiry


Write your message here and send it to us

Send Us An Inquiry


No:86990