📘 Product Overview – Yokogawa AAI543-H50
The Yokogawa AAI543-H50 is an advanced Analog Input Module used within the CENTUM CS 3000/VP control system, designed for precise and reliable analog signal acquisition. It is a high-performance 16-channel input card that supports 4-20 mA DC signals, commonly utilized in demanding industrial automation and process control environments.
The AAI543-H50 is engineered with high isolation and noise immunity, making it highly suitable for critical applications where signal integrity and system stability are essential. It also offers HART communication support, enabling enhanced diagnostic and monitoring capabilities.
✅ Product Advantages
-
High-Density Analog Input: 16 channels in a single module for compact and efficient input handling.
-
HART Protocol Support: Enables advanced diagnostics and remote device configuration.
-
Excellent Accuracy: Superior signal resolution and low drift ensure reliable performance.
-
Robust Electrical Isolation: Channel-to-channel and channel-to-ground isolation protects the system from faults and noise.
-
Long-Term Reliability: Built with industrial-grade components for extended field operation.
-
Easy Integration: Seamlessly integrates into Yokogawa’s control systems with minimal configuration.
📊 Technical Specifications
Parameter | Specification |
---|---|
Model | AAI543-H50 |
Channels | 16 Analog Input Channels |
Input Signal Range | 4–20 mA DC (with HART support) |
Resolution | 16-bit |
Isolation | Channel-to-Channel and Channel-to-Ground |
Input Resistance | 250 Ω |
Power Supply Voltage | 24 V DC (supplied from node) |
Dimensions | 107.5 × 32.8 × 130 mm |
Weight | 0.4 kg |
Operating Temperature | 0°C to 50°C |
Storage Temperature | -20°C to +70°C |
Relative Humidity | 5% to 95% (non-condensing) |
Voltage Withstanding | 1500 V AC (1 min) |
Status Indication | LEDs for module status |
Certifications | CE, CSA, FM, ATEX |
Mounting Method | Mounted on I/O base or node unit |
🏭 Applications
-
Oil & Gas Processing Plants
-
Petrochemical Refineries
-
Pharmaceutical Manufacturing
-
Power Generation Facilities
-
Water & Wastewater Treatment Plants
-
Food & Beverage Automation Systems
This module plays a critical role in analog signal acquisition from transmitters, flow meters, level sensors, and other field devices requiring precise and reliable measurement input.
🔗 Compatible Models / Modules
The AAI543-H50 is typically used in combination with the following Yokogawa components for optimal functionality:
-
Yokogawa ATB150 – Terminal block
-
Yokogawa ALR121 – Base plate for mounting
-
Yokogawa FCS (Field Control Station) – Control unit integration
-
Yokogawa HART multiplexer – For advanced HART communication routing
-
Yokogawa AAI143-H50 – Analog input module (non-HART)
-
Yokogawa AAI841-H50 – Analog input module for temperature inputs
🧰 Installation Instructions
-
Power Down the control system before installing the module to prevent damage or injury.
-
Mount the AAI543-H50 onto the dedicated terminal base (e.g., ATB150) ensuring correct orientation and firm connection.
-
Connect Analog Inputs using shielded cables to minimize electrical noise. Terminate the signal wires according to the wiring diagram provided by Yokogawa.
-
Ground Properly to ensure electrical safety and to avoid signal interference.
-
Configure the Module using the engineering tool of the CENTUM system. Assign channels and enable HART communication if required.
-
Perform Diagnostics and Validation after installation to ensure all channels are correctly receiving input and functioning.
-
Document all Wiring and Configuration settings for future reference or maintenance.
🔁 6 Related or Similar Models
Model | Description |
---|---|
AAI143-H50 | 16-channel AI module without HART support |
AAI841-H50 | AI module designed for thermocouple inputs |
ADV151-P00 | 8-channel voltage analog input module |
AAI543-S50 | Safety-rated version of AAI543 |
AAI135-H50 | 8-channel high-speed analog input module |
AAI141-H50 | 16-channel AI module, cost-optimized |
⭐ 8 Popular Yokogawa Models (With Key Parameters)
Model | Channels | Signal Type | Dimensions (mm) | Weight (kg) | Voltage |
---|---|---|---|---|---|
AAI543-H50 | 16 | 4–20 mA (HART) | 27.4 x 130 x 176 | 0.25 | 24 V DC |
AAI143-H50 | 16 | 4–20 mA | 27.4 x 130 x 176 | 0.23 | 24 V DC |
AAI841-H50 | 8 | TC/RTD | 27.4 x 130 x 176 | 0.26 | 24 V DC |
AAI135-H50 | 8 | 4–20 mA | 27.4 x 130 x 176 | 0.22 | 24 V DC |
ADV151-P00 | 8 | Voltage Input | 27.4 x 130 x 176 | 0.24 | 24 V DC |
ADV151-H50 | 8 | 4–20 mA | 27.4 x 130 x 176 | 0.25 | 24 V DC |
AAI141-H50 | 16 | 4–20 mA | 27.4 x 130 x 176 | 0.23 | 24 V DC |
AAI543-S50 | 16 | 4–20 mA (Safe) | 27.4 x 130 x 176 | 0.27 | 24 V DC |
❓ Frequently Asked Questions (FAQ)
Q1: What is the main difference between AAI543-H50 and AAI143-H50?
A1: The AAI543-H50 supports HART communication, allowing for enhanced field device diagnostics and configuration, whereas the AAI143-H50 does not support HART.
Q2: Can I use the AAI543-H50 with non-HART devices?
A2: Yes, it fully supports standard 4–20 mA signals. HART functionality is optional and only utilized when connected to HART-capable field devices.
Q3: What maintenance is required for the AAI543-H50?
A3: It requires minimal maintenance. Periodic validation of input channels and checking terminal tightness is recommended. Firmware updates may be needed occasionally.
Q4: How many modules can be installed in a single rack?
A4: This depends on the system configuration and available power. Typically, multiple AAI543-H50 modules can be installed, provided the rack has sufficient power and I/O capacity.
Q5: Is the AAI543-H50 suitable for safety instrumented systems (SIS)?
A5: No, the standard AAI543-H50 is not certified for use in SIS. Use the AAI543-S50 or other safety-rated modules for such applications.
Q6: Does this module support hot swapping?
A6: No, hot swapping is not supported. Always power down the system before removing or inserting the module to avoid damage.
Yokogawa AAI543-h50 Analog Output Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |