Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Yokogawa AAI835-H00 Product Documentation
Product Introduction
The Yokogawa AAI835-H00 is a highly reliable analog input module designed for industrial automation and process control applications. It is part of Yokogawa’s extensive lineup of signal conditioning and I/O modules, known for their precision, durability, and compatibility with various control systems.
This module is widely used in industries such as oil & gas, chemical, power generation, and water treatment, where accurate signal conversion and transmission are critical. The AAI835-H00 supports multiple input signals, including voltage and current, making it a versatile solution for diverse industrial environments.
Product Advantages
- High Accuracy – Provides precise signal conversion with minimal error, ensuring reliable data acquisition.
- Wide Input Range – Supports various analog input signals, including 4-20mA, 0-10V, and more.
- Robust Construction – Designed to withstand harsh industrial conditions, including high temperatures and electrical noise.
- Easy Integration – Compatible with Yokogawa’s control systems and third-party PLCs/DCS.
- Low Maintenance – Built for long-term reliability, reducing downtime and operational costs.
- Flexible Configuration – Allows customization of input ranges and scaling for specific application needs.
Technical Specifications
Parameter | Specification |
---|---|
Model | AAI835-H00 |
Input Type | Analog (Voltage/Current) |
Input Range | 4-20mA, 0-10V, ±10V (selectable) |
Accuracy | ±0.1% of full scale |
Resolution | 16-bit |
Isolation | 1500V AC (channel-to-system) |
Power Supply | 24V DC (±10%) |
Power Consumption | 3.5W max |
Operating Temp. | -20°C to +60°C |
Dimensions | 107.5 × 32.8 × 130 mm |
Weight | 0.3 kg |
Mounting | DIN rail or panel mount |
Applications
- Process Control Systems – Used in DCS/PLC-based automation for monitoring process variables.
- Power Plants – Measures critical parameters such as pressure, temperature, and flow.
- Oil & Gas – Ensures accurate signal transmission in hazardous environments.
- Water/Wastewater Treatment – Monitors pH, level, and other process signals.
- Manufacturing Automation – Integrates with robotic and assembly line controls.
Compatible & Recommended Models
Same Series / Related Models
Model | Type | Input/Output | Voltage | Dimensions | Weight |
---|---|---|---|---|---|
AAI143-H00 | Analog Input | 4-20mA, 0-10V | 24V DC | 45×130×110mm | 500g |
AAO835-H00 | Analog Output | 4-20mA, 0-10V | 24V DC | 45×130×110mm | 500g |
ADI835-H00 | Digital Input | 24V DC/AC | 24V DC | 45×130×110mm | 500g |
ADO835-H00 | Digital Output | Relay/Transistor | 24V DC | 45×130×110mm | 500g |
AAV835-H00 | Voltage Converter | Signal Isolation | 24V DC | 45×130×110mm | 500g |
AAR835-H00 | RTD Input | Pt100, Pt1000 | 24V DC | 45×130×110mm | 500g |
Popular Yokogawa Models
Model | Type | Input/Output | Voltage | Dimensions | Weight |
---|---|---|---|---|---|
UTAdvanced | Controller | Multi-functional | 100-240V AC | 200×150×80mm | 1.5kg |
DX1000 | Data Acquisition | High-speed logging | 24V DC | 150×100×50mm | 800g |
EJX110A | Pressure Transmitter | Differential Pressure | 10.5-42V DC | 110×110×85mm | 1.2kg |
F3RS01-0N | Flowmeter | Electromagnetic | 24V DC | 150×150×120mm | 2.0kg |
ISC40G | pH Sensor | Industrial pH/ORP | 24V DC | 120×40mm (dia) | 300g |
WM2000 | Weighing Module | Load Cell Input | 24V DC | 100×80×50mm | 600g |
YTA320 | Temp. Transmitter | Thermocouple/RTD | 12-30V DC | 55×135mm | 400g |
YVP110 | Valve Positioner | Pneumatic Control | 24V DC | 150×100×70mm | 1.0kg |
Installation Instructions
- Mounting – Secure the module on a DIN rail or panel using the provided clips.
- Wiring – Connect input signals and power supply according to the terminal diagram.
- Grounding – Ensure proper grounding to minimize electrical noise interference.
- Configuration – Set the input range and scaling via DIP switches or software.
- Testing – Verify signal accuracy using a calibrated source before full operation.
- Maintenance – Periodically check connections and clean dust/debris.
FAQ (Frequently Asked Questions)
Q1: What is the maximum input voltage supported by the AAI835-H00?
A1: The module supports up to ±10V DC, depending on the configured range.
Q2: Can the AAI835-H00 be used in hazardous areas?
A2: Yes, when installed with appropriate safety barriers or in an Ex-rated enclosure.
Q3: How do I change the input range settings?
A3: Adjust the DIP switches on the module or configure via compatible software.
Q4: What is the typical lifespan of this module?
A4: With proper usage, the module can operate reliably for over 10 years.
Q5: Is the AAI835-H00 compatible with non-Yokogawa systems?
A5: Yes, it can interface with standard PLCs/DCS using universal signal standards.
Q6: What should I do if the module fails to read signals correctly?
A6: Check wiring, power supply, and grounding first. If issues persist, contact Yokogawa support.
Yokogawa AAI835-h00 Analog I/O Modules
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |