📘 Product Introduction: Yokogawa AAR145
The Yokogawa AAR145 is a high-performance analog input module designed for use in Yokogawa’s DCS (Distributed Control System) environments. Built with precision and industrial-grade reliability, this module enables the accurate acquisition and processing of analog signals in critical automation systems. It offers seamless integration with the CENTUM VP and ProSafe-RS control systems and is typically installed in a baseplate or rack system, allowing flexible configuration in scalable process automation.
This module supports multiple analog input types and delivers real-time data acquisition for precise control and monitoring in process industries such as oil & gas, petrochemical, power generation, and water treatment facilities.
The AAR145 ensures secure and reliable operation in harsh industrial conditions, providing users with high signal integrity, minimal noise interference, and excellent long-term stability.
🌟 Product Advantages
-
High Signal Accuracy: Designed with high-resolution A/D converters, ensuring accurate analog data acquisition.
-
Modular Design: Allows flexible expansion and integration with existing Yokogawa control systems.
-
Noise Immunity: Robust EMC protection and shielding, ideal for electrically noisy industrial environments.
-
Industrial Reliability: Withstands extreme temperature, humidity, and vibration conditions common in industrial settings.
-
Easy Maintenance: Built-in diagnostics and hot-swappable design simplify field maintenance and replacement.
-
Broad Compatibility: Fully compatible with Yokogawa CENTUM VP and ProSafe-RS systems, ensuring system coherence.
📊 Technical Specifications of Yokogawa AAR145
Parameter | Specification |
---|---|
Model Number | AAR145 |
Product Type | Analog Input Module |
Number of Channels | 16 channels |
Input Signal Type | 1-5V, 4-20mA, Thermocouple (TC), RTD |
Resolution | 16-bit A/D conversion |
Accuracy | ±0.1% of full scale |
Input Impedance | ≥1MΩ (voltage input) |
Update Rate | 100 ms per channel |
Power Supply Voltage | 24 V DC (supplied via base unit) |
Operating Temperature | 0 to 60°C |
Storage Temperature | -20 to 70°C |
Humidity | 5 to 95% RH (non-condensing) |
Dimensions | 130 x 127.2 x 32.8mm |
Weight | 0.3 kg |
Mounting Method | Rack-mounted (Baseplate configuration) |
Certifications | CE, RoHS, UL, CSA |
Communication Interface | Via I/O bus connector |
🏭 Applications
-
Oil & Gas Processing Plants
For accurate field signal acquisition in upstream and downstream operations. -
Chemical and Petrochemical Industries
Monitoring temperature, pressure, and flow parameters in reactors and distillation units. -
Power Generation Facilities
Capturing real-time analog values for turbine and boiler controls. -
Water and Wastewater Treatment
Handling analog inputs for pH, turbidity, flow, and chemical dosing control. -
Pharmaceutical Manufacturing
Recording critical temperature and humidity levels for GMP compliance. -
Food & Beverage Processing
Maintaining temperature-sensitive environments for production lines.
🔗 Compatible Models
The Yokogawa AAR145 module is typically used in conjunction with the following Yokogawa components:
-
ADV151 – Analog Output Module
-
CP451 – Processor Module
-
ANB10D – I/O Node Interface Module
-
AMM12C – Analog Input Module for large-scale input systems
-
PWR001 – Power Supply Unit
-
AFV10D – Voltage Input Module
-
NFCP100 – Field Control Processor
These compatible models ensure seamless communication and operational continuity within the CENTUM VP and ProSafe-RS environments.
🛠️ Installation Instructions
-
Power Off the System:
Before installation, ensure that the power to the baseplate or rack is turned off to prevent electrical hazards. -
Slot Positioning:
Identify the designated I/O slot on the baseplate where the AAR145 is to be inserted. -
Module Insertion:
Align the module with the guide rails and push it firmly into place until it locks securely into the backplane connector. -
Wiring Connections:
Connect analog signal wires to the appropriate terminal blocks or input connector per wiring diagram provided in the manual. -
System Configuration:
Use Yokogawa’s engineering tools (such as PRM or SENG) to configure channel types, ranges, and scaling parameters. -
Diagnostics and Testing:
Power on the system and perform a self-diagnosis to confirm successful module recognition and channel integrity. -
Commissioning:
Verify that analog inputs are correctly mapped and signals are being read accurately before commissioning.
🔁 6 Related Models (Same Series or Functionally Similar)
Model | Description | Channels | Signal Type | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
AAR111 | Analog Input Module | 8 | Voltage/Current | 24 VDC | 30x130x150 | 230g |
AAR121 | High-Density Analog Input Module | 16 | Voltage/TC | 24 VDC | 30x130x150 | 240g |
AAR181 | Thermocouple Input Module | 8 | TC | 24 VDC | 30x130x150 | 250g |
AMM12C | Multi-Channel AI Module | 32 | Voltage/Current | 24 VDC | 45x130x150 | 400g |
AAV141 | Voltage Input Module | 8 | Voltage | 24 VDC | 30x130x150 | 230g |
AIP827-2 | Isolated AI Module | 16 | Current | 24 VDC | 35x130x160 | 260g |
🔝 8 Popular Yokogawa Models (All Categories)
Model | Category | Description | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
CP451-50 | CPU Module | Main processor for CENTUM VP | 5V/24V | 60x130x160 | 500g |
ADV151 | Analog Output Module | Provides analog control signals | 24 VDC | 30x130x150 | 250g |
AAI143-S00 | Analog Input Module | For TC, RTD input types | 24 VDC | 30x130x150 | 260g |
AAI841-H00 | High-Density AI | 32-channel analog input module | 24 VDC | 50x130x160 | 500g |
NFAI143-S50 | Non-Isolated AI | 16-channel voltage input | 24 VDC | 30x130x150 | 250g |
NFCP100 | Field Control Proc. | DCS processor module | 5V/24V | 65x130x160 | 520g |
PW402 | Power Supply Module | Dual-channel redundant power unit | 24 VDC | 60x130x150 | 600g |
AAM50C | AI for FOUNDATION™ | Fieldbus analog input module | 24 VDC | 35x130x150 | 290g |
❓ FAQs (Q&A Format)
Q1: What types of signals can the AAR145 handle?
A1: The AAR145 supports a variety of analog signals including 1–5 V, 4–20 mA, thermocouples (TC), and RTDs, making it suitable for a wide range of industrial sensors.
<br>
Q2: Can the AAR145 be hot-swapped without shutting down the system?
A2: Yes, the AAR145 supports hot-swapping when used in a compatible rack with redundancy features. However, it is recommended to perform this operation under guided maintenance conditions.
<br>
Q3: Is the AAR145 compatible with non-Yokogawa DCS systems?
A3: No, the AAR145 is specifically designed for integration with Yokogawa systems such as CENTUM VP and ProSafe-RS and may not be compatible with third-party control systems.
<br>
Q4: How do I configure each channel’s input type?
A4: Configuration is done through Yokogawa’s engineering workstation using system configuration tools. Each channel can be independently set to handle different input types.
<br>
Q5: What kind of maintenance is required for the AAR145?
A5: Periodic inspection of terminal connections, firmware updates (if applicable), and monitoring of diagnostic indicators are typically sufficient. No calibration is usually required unless specified.
<br>
Q6: Does the AAR145 have internal fault diagnostics?
A6: Yes, it includes built-in self-diagnostic features that detect input failures, connection errors, and communication faults, which are logged and communicated to the host system.