Yokogawa AAR145 RTD/POT 16-channel input module

Short Description:

📘 Product Introduction: Yokogawa AAR145 The Yokogawa AAR145 is a high-performance analog input module designed for use in Yokogawa’s DCS (Distributed Control System) environments. Built with precis……


  • Manufacturer: Yokogawa
  • Product Number: AAR145
  • Product Type: RTD/POT 16-channel input module
  • Origin: Japan
  • Dimensions: 130 x 127.2 x 32.8mm
  • Weight: 0.3 kg
  • Condition: New & In Stock
  • Payment Methods: T/T, PayPal, Western Union
  • Shipping Port: Xiamen, China
  • Lead Time: 1-3 Working Days
  • Warranty: One Year
  • Certificate: COO
  • Courier partners: DHL, UPS, TNT, FedEx and EMS.
0

Product Detail

Contact Us

Frequently FAQ

Real photos

Comment

Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat +8615980777398
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

📘 Product Introduction: Yokogawa AAR145

The Yokogawa AAR145 is a high-performance analog input module designed for use in Yokogawa’s DCS (Distributed Control System) environments. Built with precision and industrial-grade reliability, this module enables the accurate acquisition and processing of analog signals in critical automation systems. It offers seamless integration with the CENTUM VP and ProSafe-RS control systems and is typically installed in a baseplate or rack system, allowing flexible configuration in scalable process automation.

This module supports multiple analog input types and delivers real-time data acquisition for precise control and monitoring in process industries such as oil & gas, petrochemical, power generation, and water treatment facilities.

The AAR145 ensures secure and reliable operation in harsh industrial conditions, providing users with high signal integrity, minimal noise interference, and excellent long-term stability.


🌟 Product Advantages

  • High Signal Accuracy: Designed with high-resolution A/D converters, ensuring accurate analog data acquisition.

  • Modular Design: Allows flexible expansion and integration with existing Yokogawa control systems.

  • Noise Immunity: Robust EMC protection and shielding, ideal for electrically noisy industrial environments.

  • Industrial Reliability: Withstands extreme temperature, humidity, and vibration conditions common in industrial settings.

  • Easy Maintenance: Built-in diagnostics and hot-swappable design simplify field maintenance and replacement.

  • Broad Compatibility: Fully compatible with Yokogawa CENTUM VP and ProSafe-RS systems, ensuring system coherence.


📊 Technical Specifications of Yokogawa AAR145

Parameter Specification
Model Number AAR145
Product Type Analog Input Module
Number of Channels 16 channels
Input Signal Type 1-5V, 4-20mA, Thermocouple (TC), RTD
Resolution 16-bit A/D conversion
Accuracy ±0.1% of full scale
Input Impedance ≥1MΩ (voltage input)
Update Rate 100 ms per channel
Power Supply Voltage 24 V DC (supplied via base unit)
Operating Temperature 0 to 60°C
Storage Temperature -20 to 70°C
Humidity 5 to 95% RH (non-condensing)
Dimensions 130 x 127.2 x 32.8mm
Weight 0.3 kg
Mounting Method Rack-mounted (Baseplate configuration)
Certifications CE, RoHS, UL, CSA
Communication Interface Via I/O bus connector

🏭 Applications

  • Oil & Gas Processing Plants
    For accurate field signal acquisition in upstream and downstream operations.

  • Chemical and Petrochemical Industries
    Monitoring temperature, pressure, and flow parameters in reactors and distillation units.

  • Power Generation Facilities
    Capturing real-time analog values for turbine and boiler controls.

  • Water and Wastewater Treatment
    Handling analog inputs for pH, turbidity, flow, and chemical dosing control.

  • Pharmaceutical Manufacturing
    Recording critical temperature and humidity levels for GMP compliance.

  • Food & Beverage Processing
    Maintaining temperature-sensitive environments for production lines.


🔗 Compatible Models

The Yokogawa AAR145 module is typically used in conjunction with the following Yokogawa components:

  • ADV151 – Analog Output Module

  • CP451 – Processor Module

  • ANB10D – I/O Node Interface Module

  • AMM12C – Analog Input Module for large-scale input systems

  • PWR001 – Power Supply Unit

  • AFV10D – Voltage Input Module

  • NFCP100 – Field Control Processor

These compatible models ensure seamless communication and operational continuity within the CENTUM VP and ProSafe-RS environments.


🛠️ Installation Instructions

  1. Power Off the System:
    Before installation, ensure that the power to the baseplate or rack is turned off to prevent electrical hazards.

  2. Slot Positioning:
    Identify the designated I/O slot on the baseplate where the AAR145 is to be inserted.

  3. Module Insertion:
    Align the module with the guide rails and push it firmly into place until it locks securely into the backplane connector.

  4. Wiring Connections:
    Connect analog signal wires to the appropriate terminal blocks or input connector per wiring diagram provided in the manual.

  5. System Configuration:
    Use Yokogawa’s engineering tools (such as PRM or SENG) to configure channel types, ranges, and scaling parameters.

  6. Diagnostics and Testing:
    Power on the system and perform a self-diagnosis to confirm successful module recognition and channel integrity.

  7. Commissioning:
    Verify that analog inputs are correctly mapped and signals are being read accurately before commissioning.


🔁 6 Related Models (Same Series or Functionally Similar)

Model Description Channels Signal Type Voltage Dimensions (mm) Weight
AAR111 Analog Input Module 8 Voltage/Current 24 VDC 30x130x150 230g
AAR121 High-Density Analog Input Module 16 Voltage/TC 24 VDC 30x130x150 240g
AAR181 Thermocouple Input Module 8 TC 24 VDC 30x130x150 250g
AMM12C Multi-Channel AI Module 32 Voltage/Current 24 VDC 45x130x150 400g
AAV141 Voltage Input Module 8 Voltage 24 VDC 30x130x150 230g
AIP827-2 Isolated AI Module 16 Current 24 VDC 35x130x160 260g

🔝 8 Popular Yokogawa Models (All Categories)

Model Category Description Voltage Dimensions (mm) Weight
CP451-50 CPU Module Main processor for CENTUM VP 5V/24V 60x130x160 500g
ADV151 Analog Output Module Provides analog control signals 24 VDC 30x130x150 250g
AAI143-S00 Analog Input Module For TC, RTD input types 24 VDC 30x130x150 260g
AAI841-H00 High-Density AI 32-channel analog input module 24 VDC 50x130x160 500g
NFAI143-S50 Non-Isolated AI 16-channel voltage input 24 VDC 30x130x150 250g
NFCP100 Field Control Proc. DCS processor module 5V/24V 65x130x160 520g
PW402 Power Supply Module Dual-channel redundant power unit 24 VDC 60x130x150 600g
AAM50C AI for FOUNDATION™ Fieldbus analog input module 24 VDC 35x130x150 290g

FAQs (Q&A Format)

Q1: What types of signals can the AAR145 handle?
A1: The AAR145 supports a variety of analog signals including 1–5 V, 4–20 mA, thermocouples (TC), and RTDs, making it suitable for a wide range of industrial sensors.

<br>

Q2: Can the AAR145 be hot-swapped without shutting down the system?
A2: Yes, the AAR145 supports hot-swapping when used in a compatible rack with redundancy features. However, it is recommended to perform this operation under guided maintenance conditions.

<br>

Q3: Is the AAR145 compatible with non-Yokogawa DCS systems?
A3: No, the AAR145 is specifically designed for integration with Yokogawa systems such as CENTUM VP and ProSafe-RS and may not be compatible with third-party control systems.

<br>

Q4: How do I configure each channel’s input type?
A4: Configuration is done through Yokogawa’s engineering workstation using system configuration tools. Each channel can be independently set to handle different input types.

<br>

Q5: What kind of maintenance is required for the AAR145?
A5: Periodic inspection of terminal connections, firmware updates (if applicable), and monitoring of diagnostic indicators are typically sufficient. No calibration is usually required unless specified.

<br>

Q6: Does the AAR145 have internal fault diagnostics?
A6: Yes, it includes built-in self-diagnostic features that detect input failures, connection errors, and communication faults, which are logged and communicated to the host system.

Yokogawa AAR145 RTD/POT 16-channel input module

Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat +8615980777398
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China
Does this product come with a warranty?
Yes, we offer a 1-year warranty and support returns and exchanges to fully protect your rights.
How to verify products before purchase?
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation.
How long does shipping take?
Shipping times vary by location. With our 16 global warehouses, we strive for fast delivery. Contact us for an estimated delivery time.
What is the minimum order quantity (MOQ)?
The MOQ is usually one unit. For bulk orders, please contact us for discounts and pricing details.
Can I get discounts for bulk purchases?
Yes, we offer competitive pricing for bulk purchases. Contact our sales team for a custom quote.
What payment methods do you accept for wholesale orders?
We accept various methods, including bank transfers (T/T), letters of credit (L/C), and more upon agreement.
Can I purchase different quantities of a product?
Yes, we offer flexible ordering options, whether you need a single unit or a large batch.
Are there discounts for new wholesale customers?
We occasionally offer promotional discounts for new wholesale customers. Contact us for current offers.
How can I ensure compatibility with my existing systems?
If unsure, please provide your system details, and our support team will verify compatibility before purchase.
Can I return products if they don’t meet my requirements?
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Return shipping costs are the buyer's responsibility.
Do you provide technical support or installation services?
Yes, we offer technical support for installation, configuration, and troubleshooting.

Yokogawa AAR145 RTD/POT 16-channel input module

Yokogawa AAR145 RTD/POT 16-channel input module

Yokogawa AAR145 RTD/POT 16-channel input module

Yokogawa AAR145 RTD/POT 16-channel input module

Comment
Please leave your comments, we value your opinions very much.
*
*
*

Hot Tags


Prev or Next


Send Us An Inquiry


Write your message here and send it to us

Send Us An Inquiry


No:86990