Yokogawa AIP171-S2 Module
Product Introduction
The Yokogawa AIP171-S2 is a high-performance analog input module designed for integration with the CENTUM VP Distributed Control System (DCS). Engineered for reliability and precision, the AIP171-S2 supports a wide range of analog signal inputs, including voltage and current signals, making it suitable for a broad spectrum of industrial automation applications.
This module features isolated input channels that enhance signal integrity and prevent ground loop issues. With its rugged build quality, modular architecture, and hot-swappable capability, the AIP171-S2 ensures seamless operation even in harsh environments. It is widely used in industries such as oil & gas, petrochemical, power generation, water treatment, and more.
Product Advantages
-
High Channel Density: Accommodates up to 16 analog input channels, optimizing control panel space.
-
Advanced Signal Isolation: Isolated channels help minimize noise and interference.
-
Hot Swappable: Enables maintenance without system shutdown, ensuring high system availability.
-
Precision Measurement: High-resolution input ensures accurate data acquisition.
-
Robust Build Quality: Suitable for use in demanding industrial environments.
-
Seamless Integration: Fully compatible with the Yokogawa CENTUM VP and ProSafe-RS systems.
Technical Specifications
Parameter | Details |
---|---|
Model Number | AIP171-S2 |
Input Channels | 16 isolated channels |
Input Signal Type | 4–20 mA DC, 1–5 V DC, others configurable |
Resolution | 16-bit |
Isolation | Channel-to-channel and channel-to-ground |
Input Accuracy | ±0.1% of full scale |
Operating Voltage | 24 V DC (supplied via base unit) |
Power Consumption | Approx. 4.5 W |
Operating Temperature | 0 to 50°C |
Storage Temperature | -20 to 70°C |
Relative Humidity | 5% to 95% RH (non-condensing) |
Dimensions (W x H x D) | 27.2 × 130 × 176 mm |
Weight | 0.3 kg |
Mounting | Mounted on N-IO base unit |
Certifications | CE, CSA, ATEX (select models) |
Product Applications
-
Oil & Gas Industry: Monitoring pressure, temperature, and flow sensors on offshore and onshore rigs.
-
Chemical & Petrochemical Plants: Input for chemical reaction process control and monitoring.
-
Power Generation: Measurement of analog signals from turbines, boilers, and transformers.
-
Water & Wastewater Treatment: Continuous monitoring of water quality parameters.
-
Pulp and Paper Mills: Analog input from instrumentation in pulp preparation and paper machines.
-
Food & Beverage Processing: Signal input from temperature and humidity sensors in processing lines.
Compatible and Supported Models
The AIP171-S2 is designed to operate with the following Yokogawa systems and modules:
-
VP6B1710 (Base Unit for Analog I/O)
-
PW402 (Power Supply Module)
-
ALR121-S1 (Loop Relay Module)
-
YCB301 (Control Bus Cable)
-
CPU Modules: AFV10D / AFV30D (CENTUM VP Controller)
-
Yokogawa Field Instruments (Temperature transmitters, flowmeters, etc.)
Installation Instructions
-
Safety First: Ensure all power sources to the control panel are switched off before installation.
-
Mounting the Module: Insert the AIP171-S2 module vertically into the designated slot on the base unit (VP6B1710).
-
Secure the Module: Once inserted, lock the module using the side latches to ensure firm mechanical contact.
-
Wiring the Inputs: Connect the analog input signals to the screw terminals on the base unit associated with the AIP171-S2.
-
Power Connection: Ensure the base unit is powered by a regulated 24 V DC source. The module receives power from the base.
-
System Configuration: Using the CENTUM VP engineering tool, configure each input channel for signal type, scaling, and diagnostics.
-
Hot Swap: The module can be replaced without shutting down the system, thanks to the hot-swappable feature.
-
Final Checks: Power up the system and verify module recognition and input signal readings from the HMI or engineering station.
6 Related Models (Same or Similar Series)
Model | Function | Channels | Signal Type | Dimensions (mm) | Weight | Voltage |
---|---|---|---|---|---|---|
AIP171-S1 | Analog Input Module | 16 | 4–20 mA | 27.2×130×176 | 0.3 kg | 24 V DC |
AOP171-S2 | Analog Output Module | 8 | 4–20 mA | 27.2×130×176 | 0.3 kg | 24 V DC |
AIP411 | High-Speed Analog Input Module | 8 | ±10 V | 27.2×130×176 | 0.35 kg | 24 V DC |
AIP132 | 32-Channel Analog Input Module | 32 | 1–5 V | 40×130×176 | 0.5 kg | 24 V DC |
ADV151-P03 | Multipoint AI with HART | 16 | 4–20 mA + HART | 27.2×130×176 | 0.4 kg | 24 V DC |
AIP502 | Field I/O Analog Input | 8 | 4–20 mA | 27.2×130×176 | 0.35 kg | 24 V DC |
8 Popular Yokogawa Models (With Specifications)
Model | Type | Function | Channels | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
AIP171-S2 | Analog Input Module | 16 AI channels | 16 | 24 V DC | 27.2×130×176 | 0.3 kg |
AOP171-S2 | Analog Output Module | 8 AO channels | 8 | 24 V DC | 27.2×130×176 | 0.3 kg |
CP451-50 | CPU Module | Controller for DCS | — | 5 V DC | 50×180×176 | 0.6 kg |
NFAI143-S50 | Analog Input Module | 16 HART-enabled AI | 16 | 24 V DC | 27.2×130×176 | 0.35 kg |
F3LE11-0T | Digital I/O Module | 16 DO channels | 16 | 24 V DC | 27.2×130×176 | 0.3 kg |
NFDV161-P50 | Digital Input Module | 16 DI channels | 16 | 24 V DC | 27.2×130×176 | 0.3 kg |
ADV551-P03 | Analog Output (HART) | 8 AO HART channels | 8 | 24 V DC | 27.2×130×176 | 0.35 kg |
AMM12C | Multiplexed Analog Input | 32-channel AI | 32 | 24 V DC | 40×130×176 | 0.5 kg |
FAQ (Frequently Asked Questions)
Q1: What is the primary function of the AIP171-S2 module?
A1: The AIP171-S2 is designed to collect analog signals (such as 4–20 mA or 1–5 V) from field instruments and transmit them to the DCS system for processing and monitoring.
Q2: Can the AIP171-S2 handle HART communication signals?
A2: No, the AIP171-S2 does not support HART. For analog input with HART protocol, the ADV151-P03 model is recommended.
Q3: Is the AIP171-S2 hot-swappable?
A3: Yes, it can be replaced or removed while the system is powered on, which enhances maintenance efficiency.
Q4: What tools are required to configure the AIP171-S2?
A4: Configuration is performed via Yokogawa’s CENTUM VP engineering workstation using the corresponding software environment.
Q5: How do I verify if the module is working correctly after installation?
A5: Once installed, the module’s LED indicators will show its operational status, and signal readings can be confirmed from the operator station or engineering interface.
Q6: What is the difference between AIP171-S2 and AIP171-S1?
A6: The AIP171-S2 is an updated version with improved noise immunity and stability. Both offer similar input specifications but may differ in firmware compatibility.
Yokogawa AIP171-S2 Transceiver Control Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |