Yokogawa AIP171 TRANSCEIVER CONTROL MODULE

Short Description:

Product Introduction – Yokogawa AIP171 The Yokogawa AIP171 is an Analog Input Module designed for use in the Yokogawa CENTUM VP distributed control system (DCS). Engineered to provide reliable and ……


  • Manufacturer: Yokogawa
  • Product Number: AIP171
  • Product Type: TRANSCEIVER CONTROL MODULE
  • Origin: Japan
  • Dimensions: 27.9 x 130 x 180 mm
  • Weight: 0.4 kg
  • Condition: New & In Stock
  • Payment Methods: T/T, PayPal, Western Union
  • Shipping Port: Xiamen, China
  • Lead Time: 1-3 Working Days
  • Warranty: One Year
  • Certificate: COO
  • Courier partners: DHL, UPS, TNT, FedEx and EMS.
4

Product Detail

Contact Us

Frequently FAQ

Real photos

Comment

Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat +8615980777398
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Product Introduction – Yokogawa AIP171

The Yokogawa AIP171 is an Analog Input Module designed for use in the Yokogawa CENTUM VP distributed control system (DCS). Engineered to provide reliable and accurate analog signal acquisition, the AIP171 serves as a critical interface between field instrumentation and control logic, making it indispensable in process automation environments. This module ensures high-precision analog input conversion, contributing to improved system control accuracy and process optimization.

The AIP171 supports a wide range of analog input signal types, including 1–5 V, 4–20 mA, and thermocouple input types, and features built-in isolation and diagnostics to enhance system safety and performance. It is typically installed in a Field Control Station (FCS) and used for applications involving temperature, pressure, flow, and other analog measurements.


Product Advantages

  • High Signal Accuracy: Offers precision analog-to-digital conversion for reliable signal acquisition from field devices.

  • Multi-Input Capability: Supports multiple signal types including voltage, current, and thermocouple inputs.

  • Channel Isolation: Ensures safe and independent signal transmission with galvanic isolation between channels.

  • Robust Diagnostics: Built-in self-diagnostics help detect wiring errors, signal failure, or degradation.

  • Environmental Durability: Designed to operate in industrial conditions with resistance to temperature, vibration, and electrical interference.

  • Easy Integration: Seamlessly integrates into CENTUM VP and CENTUM CS 3000 control systems, reducing setup time.


Technical Specifications – Yokogawa AIP171

Parameter Specification
Module Type Analog Input Module (AI)
Signal Input Types 1–5 V DC, 4–20 mA DC, Thermocouple, RTD
Number of Channels 16 analog input channels
Resolution 16-bit ADC
Isolation Channel-to-channel and channel-to-ground isolation
Input Impedance 250 Ω (for current), >1 MΩ (for voltage)
Accuracy ±0.1% of full scale
Voltage Requirement 24 V DC (supplied from I/O base)
Power Consumption Approx. 3.5 W
Dimensions (W x H x D) 27.9 x 130 x 180 mm
Weight  0.4 kg
Operating Temperature 0 to 60°C
Storage Temperature -20 to 70°C
Humidity Range 5% to 95% RH (non-condensing)
EMC/EMI Compliance IEC/EN standards
Mounting Mounted on V-bus baseplate

Application Areas

The Yokogawa AIP171 Analog Input Module is suitable for use in a wide variety of industries and applications, such as:

  • Oil and Gas Refining

  • Petrochemical and Chemical Plants

  • Power Generation

  • Water and Wastewater Treatment

  • Pharmaceutical Manufacturing

  • Food and Beverage Processing

  • Pulp and Paper Industry

  • Metals and Mining

It is commonly applied in systems requiring accurate and real-time monitoring of temperature, flow rate, pressure, and other analog process variables.


Compatible and Accessory Models

The AIP171 is typically used with the following Yokogawa control system modules and components:

  • Yokogawa CPU Module (e.g., CP471)

  • Power Supply Modules (e.g., PW482, PW402)

  • Communication Modules (e.g., EC401, ALR121)

  • Terminal Blocks (e.g., TB805A)

  • Baseplate (NFBP Series)

  • CENTUM VP Field Control Station (FCS)

These modules collectively form the robust architecture of the CENTUM VP DCS, with AIP171 acting as the analog input interface.


Installation Instructions

  1. Preparation
    Ensure the system is powered down before beginning installation. Verify that the baseplate is correctly installed and grounded.

  2. Module Placement
    Insert the AIP171 module into the designated slot on the I/O baseplate, ensuring it aligns correctly with the guide rails.

  3. Secure the Module
    Gently press the module into place and tighten the locking levers or screws to prevent vibration-based displacement.

  4. Wiring the Inputs
    Connect the analog input wires to the corresponding terminal block, ensuring correct polarity and channel mapping.

  5. Configuration
    Use the system engineering tool to configure input types, scaling, and tag assignments. Perform signal simulation for testing.

  6. Power On and Test
    Power up the system and verify proper communication between the AIP171 and the controller. Check for diagnostic messages or errors.


Related or Same-Series Models

Model Description Channels Signal Type Mounting
AIP171 Analog Input Module 16 Voltage/Current Baseplate
AIP172 Enhanced Analog Input Module 16 Voltage/Current/RTD Baseplate
AIP161 Analog Input Module (Standard Version) 8 Voltage/Current Baseplate
AIP163 High-Density Analog Input Module 32 4–20 mA Baseplate
AIP511 AI Module for ProSafe-RS SIS 16 4–20 mA, HART Safety Baseplate
AIP523 AI Module (Temperature-focused) 8 RTD/Thermocouple Safety Baseplate

Popular Yokogawa Models

Model Description Type Dimensions (mm) Weight (kg) Voltage
CP471 FCS Processor Module CPU 30 x 130 x 180 0.5 24 V DC
AIP171 Analog Input Module I/O 27.9 x 130 x 180 0.4 24 V DC
AOP151 Analog Output Module I/O 27.9 x 130 x 180 0.45 24 V DC
DVP143 Digital Input Module I/O 27.9 x 130 x 180 0.4 24 V DC
CP451-10 Compact CPU for FCS CPU 35 x 130 x 180 0.52 24 V DC
NFAI143-S50 Field Analog Input Module Remote I/O 40 x 130 x 180 0.55 24 V DC
NFCP100 Compact Processor for Remote I/O CPU 35 x 130 x 180 0.45 24 V DC
NFDV161-P50 Digital Input Module (Field I/O) Remote I/O 40 x 130 x 180 0.5 24 V DC

Frequently Asked Questions (FAQs)

Q1: What type of signals does the Yokogawa AIP171 support?
A1: The AIP171 supports a wide range of analog signals, including 1–5 V DC, 4–20 mA DC, RTDs, and thermocouples. It is versatile for various measurement needs in industrial automation.

Q2: Is the AIP171 compatible with both CENTUM VP and CS 3000 systems?
A2: Yes, the AIP171 is fully compatible with both CENTUM VP and CENTUM CS 3000 systems. It integrates seamlessly into the system architecture for signal processing.

Q3: How many analog input channels does the AIP171 have?
A3: The AIP171 provides 16 analog input channels, each of which can be independently configured for different signal types.

Q4: Can the AIP171 be used in safety instrumented systems (SIS)?
A4: No, the AIP171 is not SIS-certified. For safety applications, Yokogawa offers ProSafe-RS modules such as AIP511 and AIP523, which are certified for use in SIL environments.

Q5: What diagnostic features are available on the AIP171?
A5: The AIP171 includes internal diagnostics such as signal error detection, wiring fault identification, and module health status reporting.

Q6: What are the environmental conditions required for AIP171 operation?
A6: The module is designed for industrial environments and operates within 0–60°C, with humidity levels ranging from 5% to 95% non-condensing.

Yokogawa AIP171 TRANSCEIVER CONTROL MODULE

Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat +8615980777398
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China
Does this product come with a warranty?
Yes, we offer a 1-year warranty and support returns and exchanges to fully protect your rights.
How to verify products before purchase?
We can provide detailed product images upon request, and our team can arrange warehouse photos for confirmation.
How long does shipping take?
Shipping times vary by location. With our 16 global warehouses, we strive for fast delivery. Contact us for an estimated delivery time.
What is the minimum order quantity (MOQ)?
The MOQ is usually one unit. For bulk orders, please contact us for discounts and pricing details.
Can I get discounts for bulk purchases?
Yes, we offer competitive pricing for bulk purchases. Contact our sales team for a custom quote.
What payment methods do you accept for wholesale orders?
We accept various methods, including bank transfers (T/T), letters of credit (L/C), and more upon agreement.
Can I purchase different quantities of a product?
Yes, we offer flexible ordering options, whether you need a single unit or a large batch.
Are there discounts for new wholesale customers?
We occasionally offer promotional discounts for new wholesale customers. Contact us for current offers.
How can I ensure compatibility with my existing systems?
If unsure, please provide your system details, and our support team will verify compatibility before purchase.
Can I return products if they don’t meet my requirements?
Returns are accepted within 30 days if the product is unused, unopened, and in its original packaging. Return shipping costs are the buyer's responsibility.
Do you provide technical support or installation services?
Yes, we offer technical support for installation, configuration, and troubleshooting.

Yokogawa AIP171 TRANSCEIVER CONTROL MODULE

Yokogawa AIP171 TRANSCEIVER CONTROL MODULE

Yokogawa AIP171 TRANSCEIVER CONTROL MODULE

Yokogawa AIP171 TRANSCEIVER CONTROL MODULE

Comment
Please leave your comments, we value your opinions very much.
*
*
*

Hot Tags


Prev or Next


Send Us An Inquiry


Write your message here and send it to us

Send Us An Inquiry


No:86990