Product Introduction – Yokogawa AIP171
The Yokogawa AIP171 is an Analog Input Module designed for use in the Yokogawa CENTUM VP distributed control system (DCS). Engineered to provide reliable and accurate analog signal acquisition, the AIP171 serves as a critical interface between field instrumentation and control logic, making it indispensable in process automation environments. This module ensures high-precision analog input conversion, contributing to improved system control accuracy and process optimization.
The AIP171 supports a wide range of analog input signal types, including 1–5 V, 4–20 mA, and thermocouple input types, and features built-in isolation and diagnostics to enhance system safety and performance. It is typically installed in a Field Control Station (FCS) and used for applications involving temperature, pressure, flow, and other analog measurements.
Product Advantages
-
High Signal Accuracy: Offers precision analog-to-digital conversion for reliable signal acquisition from field devices.
-
Multi-Input Capability: Supports multiple signal types including voltage, current, and thermocouple inputs.
-
Channel Isolation: Ensures safe and independent signal transmission with galvanic isolation between channels.
-
Robust Diagnostics: Built-in self-diagnostics help detect wiring errors, signal failure, or degradation.
-
Environmental Durability: Designed to operate in industrial conditions with resistance to temperature, vibration, and electrical interference.
-
Easy Integration: Seamlessly integrates into CENTUM VP and CENTUM CS 3000 control systems, reducing setup time.
Technical Specifications – Yokogawa AIP171
Parameter | Specification |
---|---|
Module Type | Analog Input Module (AI) |
Signal Input Types | 1–5 V DC, 4–20 mA DC, Thermocouple, RTD |
Number of Channels | 16 analog input channels |
Resolution | 16-bit ADC |
Isolation | Channel-to-channel and channel-to-ground isolation |
Input Impedance | 250 Ω (for current), >1 MΩ (for voltage) |
Accuracy | ±0.1% of full scale |
Voltage Requirement | 24 V DC (supplied from I/O base) |
Power Consumption | Approx. 3.5 W |
Dimensions (W x H x D) | 27.9 x 130 x 180 mm |
Weight | 0.4 kg |
Operating Temperature | 0 to 60°C |
Storage Temperature | -20 to 70°C |
Humidity Range | 5% to 95% RH (non-condensing) |
EMC/EMI Compliance | IEC/EN standards |
Mounting | Mounted on V-bus baseplate |
Application Areas
The Yokogawa AIP171 Analog Input Module is suitable for use in a wide variety of industries and applications, such as:
-
Oil and Gas Refining
-
Petrochemical and Chemical Plants
-
Power Generation
-
Water and Wastewater Treatment
-
Pharmaceutical Manufacturing
-
Food and Beverage Processing
-
Pulp and Paper Industry
-
Metals and Mining
It is commonly applied in systems requiring accurate and real-time monitoring of temperature, flow rate, pressure, and other analog process variables.
Compatible and Accessory Models
The AIP171 is typically used with the following Yokogawa control system modules and components:
-
Yokogawa CPU Module (e.g., CP471)
-
Power Supply Modules (e.g., PW482, PW402)
-
Communication Modules (e.g., EC401, ALR121)
-
Terminal Blocks (e.g., TB805A)
-
Baseplate (NFBP Series)
-
CENTUM VP Field Control Station (FCS)
These modules collectively form the robust architecture of the CENTUM VP DCS, with AIP171 acting as the analog input interface.
Installation Instructions
-
Preparation
Ensure the system is powered down before beginning installation. Verify that the baseplate is correctly installed and grounded. -
Module Placement
Insert the AIP171 module into the designated slot on the I/O baseplate, ensuring it aligns correctly with the guide rails. -
Secure the Module
Gently press the module into place and tighten the locking levers or screws to prevent vibration-based displacement. -
Wiring the Inputs
Connect the analog input wires to the corresponding terminal block, ensuring correct polarity and channel mapping. -
Configuration
Use the system engineering tool to configure input types, scaling, and tag assignments. Perform signal simulation for testing. -
Power On and Test
Power up the system and verify proper communication between the AIP171 and the controller. Check for diagnostic messages or errors.
Related or Same-Series Models
Model | Description | Channels | Signal Type | Mounting |
---|---|---|---|---|
AIP171 | Analog Input Module | 16 | Voltage/Current | Baseplate |
AIP172 | Enhanced Analog Input Module | 16 | Voltage/Current/RTD | Baseplate |
AIP161 | Analog Input Module (Standard Version) | 8 | Voltage/Current | Baseplate |
AIP163 | High-Density Analog Input Module | 32 | 4–20 mA | Baseplate |
AIP511 | AI Module for ProSafe-RS SIS | 16 | 4–20 mA, HART | Safety Baseplate |
AIP523 | AI Module (Temperature-focused) | 8 | RTD/Thermocouple | Safety Baseplate |
Popular Yokogawa Models
Model | Description | Type | Dimensions (mm) | Weight (kg) | Voltage |
---|---|---|---|---|---|
CP471 | FCS Processor Module | CPU | 30 x 130 x 180 | 0.5 | 24 V DC |
AIP171 | Analog Input Module | I/O | 27.9 x 130 x 180 | 0.4 | 24 V DC |
AOP151 | Analog Output Module | I/O | 27.9 x 130 x 180 | 0.45 | 24 V DC |
DVP143 | Digital Input Module | I/O | 27.9 x 130 x 180 | 0.4 | 24 V DC |
CP451-10 | Compact CPU for FCS | CPU | 35 x 130 x 180 | 0.52 | 24 V DC |
NFAI143-S50 | Field Analog Input Module | Remote I/O | 40 x 130 x 180 | 0.55 | 24 V DC |
NFCP100 | Compact Processor for Remote I/O | CPU | 35 x 130 x 180 | 0.45 | 24 V DC |
NFDV161-P50 | Digital Input Module (Field I/O) | Remote I/O | 40 x 130 x 180 | 0.5 | 24 V DC |
Frequently Asked Questions (FAQs)
Q1: What type of signals does the Yokogawa AIP171 support?
A1: The AIP171 supports a wide range of analog signals, including 1–5 V DC, 4–20 mA DC, RTDs, and thermocouples. It is versatile for various measurement needs in industrial automation.
Q2: Is the AIP171 compatible with both CENTUM VP and CS 3000 systems?
A2: Yes, the AIP171 is fully compatible with both CENTUM VP and CENTUM CS 3000 systems. It integrates seamlessly into the system architecture for signal processing.
Q3: How many analog input channels does the AIP171 have?
A3: The AIP171 provides 16 analog input channels, each of which can be independently configured for different signal types.
Q4: Can the AIP171 be used in safety instrumented systems (SIS)?
A4: No, the AIP171 is not SIS-certified. For safety applications, Yokogawa offers ProSafe-RS modules such as AIP511 and AIP523, which are certified for use in SIL environments.
Q5: What diagnostic features are available on the AIP171?
A5: The AIP171 includes internal diagnostics such as signal error detection, wiring fault identification, and module health status reporting.
Q6: What are the environmental conditions required for AIP171 operation?
A6: The module is designed for industrial environments and operates within 0–60°C, with humidity levels ranging from 5% to 95% non-condensing.
Yokogawa AIP171 TRANSCEIVER CONTROL MODULE