Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introduction
The Yokogawa ASD533 is a high-performance analog output module designed for integration within distributed control systems (DCS). As part of Yokogawa’s reliable I/O subsystem, it offers precise analog signal output for control and monitoring tasks. Engineered with robust circuitry and seamless communication protocols, the ASD533 is tailored for critical industrial applications where signal accuracy, reliability, and real-time responsiveness are essential.
The ASD533 serves as an essential component for interfacing between control logic and analog output devices such as control valves, actuators, and indicators. It is built to operate under demanding conditions, with full compliance to industrial standards for electromagnetic compatibility, thermal resistance, and vibration endurance.
Product Advantages
-
High Accuracy Output: Delivers stable and precise analog signals, ensuring optimal control of field devices.
-
Robust Environmental Tolerance: Designed to withstand harsh industrial environments including temperature fluctuations, dust, and electrical interference.
-
Seamless Integration: Fully compatible with Yokogawa DCS systems, especially CENTUM VP and CS 3000 series.
-
Modular Architecture: Enables easy replacement, configuration, and maintenance, reducing downtime and operational costs.
-
Advanced Diagnostics: Offers comprehensive self-diagnostic features and loop monitoring, contributing to improved system reliability and ease of troubleshooting.
-
Long Operational Life: Constructed using industrial-grade components for extended field use without degradation of performance.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | ASD533 |
Product Type | Analog Output Module |
Output Channels | 4 channels |
Output Signal Type | 4–20 mA DC (analog current output) |
Load Resistance Range | 0–750 ohms |
Resolution | 12 bits |
Accuracy | ±0.1% of span |
Output Update Rate | 10 ms |
Operating Voltage | 24 V DC nominal (19.2–28.8 V DC range) |
Power Consumption | 3.0 W (typical) |
Operating Temperature | -20°C to +60°C |
Storage Temperature | -40°C to +85°C |
Relative Humidity | 5% to 95% RH (non-condensing) |
Dimensions | 107.5 × 130 × 32.8 mm |
Weight | 0.3 kg |
Mounting Type | DIN rail or baseplate mounted |
Isolation | Channel-to-Channel and Channel-to-Ground |
Certifications | CE, CSA, UL, RoHS compliant |
Applications
The Yokogawa ASD533 analog output module is extensively used across a variety of industries and process control environments, including:
-
Oil & Gas: Control of valves and actuators in upstream and downstream operations
-
Chemical & Petrochemical: Accurate chemical dosing and temperature modulation
-
Power Generation: Turbine control and environmental regulation systems
-
Pharmaceutical: Precision fluid control for manufacturing processes
-
Water & Wastewater Treatment: Regulating pumps and valves in treatment cycles
-
Food & Beverage: Controlling steam, flow, and pressure in processing lines
Compatible Models for Integration
The ASD533 is fully compatible with the following Yokogawa systems and I/O bases:
-
Yokogawa CP451-50 – Processor Module
-
Yokogawa ALR121 – Power Supply Unit
-
Yokogawa AMM12C – Analog Input Module
-
Yokogawa AAI143-H00 – Enhanced Analog Input Module
-
Yokogawa ANB10D – Node Interface Unit
-
Yokogawa ADV151 – Digital Output Module
Installation Instructions
-
Safety First: Ensure the control system is powered down and locked out before installing the module.
-
Mounting: Mount the ASD533 module securely onto a compatible baseplate or DIN rail within the control panel.
-
Wiring: Connect each output channel to the corresponding field device. Use shielded twisted-pair cables for analog signals to reduce noise interference.
-
Power Supply: Ensure the module receives 24 V DC power from a regulated source.
-
Configuration: Use Yokogawa’s engineering tool (e.g., CENTUM VP’s System View) to configure channel parameters, output ranges, and diagnostics.
-
Testing: After installation, perform loop checks to verify signal transmission and output accuracy.
-
Commissioning: Finalize the setup by integrating the module into the DCS logic and validating system performance.
Related Models (Same Series or Function)
Model | Description | Output Type | Voltage | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|---|
ASD531 | 2-channel analog output module | 4–20 mA DC | 24 V DC | 30 x 130 x 100 | 0.22 |
ASD534 | 8-channel analog output module | 4–20 mA DC | 24 V DC | 50 x 130 x 100 | 0.30 |
AAI543-H00 | High-speed analog output module | ±10V | 24 V DC | 30 x 130 x 100 | 0.26 |
ADV151 | Digital output (complementary model) | 24 V DC digital | 24 V DC | 30 x 130 x 100 | 0.24 |
AAI143-S00 | Analog input module | 4–20 mA DC | 24 V DC | 30 x 130 x 100 | 0.25 |
AAR181-S00 | Control processor interface module | N/A | 24 V DC | 30 x 130 x 100 | 0.28 |
Popular Yokogawa Models
Model | Description | Function | Voltage | Dimensions (mm) | Weight (kg) |
---|---|---|---|---|---|
CP451-50 | Central Processor Module | CPU | 24 V DC | 50 x 150 x 130 | 0.45 |
AAI143-H00 | Analog Input Module | AI (4–20 mA) | 24 V DC | 30 x 130 x 100 | 0.25 |
AAR181-S00 | Control Processor Interface Module | Processor Interface | 24 V DC | 30 x 130 x 100 | 0.28 |
ADV151 | Digital Output Module | DO (24 V) | 24 V DC | 30 x 130 x 100 | 0.24 |
PW402 | Power Supply Unit | Power Supply | 24 V DC | 50 x 150 x 120 | 0.50 |
NFDV161-P50 | Field Control Station | I/O Terminal Block | 24 V DC | 60 x 140 x 120 | 0.40 |
F3LE11-0T | Logic Input Module | DI (logic) | 24 V DC | 30 x 130 x 100 | 0.22 |
AAI835-H00 | High-Density AI Module | AI (16 channels) | 24 V DC | 50 x 130 x 100 | 0.32 |
Frequently Asked Questions (FAQs)
Q1: What is the primary function of the Yokogawa ASD533?
A1: The ASD533 is an analog output module designed to transmit 4–20 mA DC signals to field devices such as control valves or indicators, based on control commands from a Yokogawa DCS.
Q2: Can the ASD533 be used in hazardous environments?
A2: While the module itself is not intrinsically safe, it can be installed in systems using intrinsic safety barriers or in approved enclosures for hazardous environments.
Q3: How do I test if a channel on the ASD533 is working correctly?
A3: Use a multimeter to measure current output across the terminal blocks while the system is in test mode. You can also utilize the DCS diagnostics for live data feedback.
Q4: Is there a need for external isolation when using the ASD533?
A4: No, the ASD533 includes internal isolation between channels and from ground, eliminating the need for external isolation in most cases.
Q5: How many ASD533 modules can be installed in one system?
A5: This depends on the I/O capacity of the system node. Multiple modules can be installed as long as power and addressing constraints are observed.
Q6: Does Yokogawa provide software for configuring the ASD533?
A6: Yes, the module is configured via Yokogawa’s engineering tools such as CENTUM VP or the system configuration console used in CS 3000 systems.
Yokogawa ASD533 Digital Output Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |