Yokogawa EC402-51 Product Introduction
The Yokogawa EC402-51 is a high-performance electrochemical analyzer designed for precise measurement and control of pH, ORP (Oxidation-Reduction Potential), and conductivity in industrial processes. It is widely used in water treatment, chemical processing, pharmaceuticals, and food & beverage industries. The EC402-51 features advanced diagnostics, robust construction, and user-friendly operation, making it a reliable choice for critical applications.
The analyzer is equipped with a large, easy-to-read LCD display and supports multiple communication protocols, including 4-20 mA output, HART, and Modbus. Its modular design allows for flexible configurations to meet specific process requirements.
Product Advantages
- High Accuracy and Stability: The EC402-51 delivers precise measurements with minimal drift, ensuring long-term reliability.
- Advanced Diagnostics: Built-in self-diagnostics and alarm functions reduce maintenance time and improve operational efficiency.
- Durable Construction: Designed to withstand harsh industrial environments, including high temperatures and corrosive conditions.
- User-Friendly Interface: Intuitive menu navigation and a clear display simplify operation and setup.
- Flexible Communication Options: Supports multiple communication protocols for seamless integration into control systems.
- Low Maintenance: Features like automatic calibration and cleaning reduce the need for manual intervention.
Technical Parameters
Parameter | Specification |
---|---|
Measurement Range | pH: 0-14, ORP: ±2000 mV, Conductivity: 0-2000 µS/cm |
Accuracy | pH: ±0.01, ORP: ±1 mV, Conductivity: ±0.5% FS |
Display | Backlit LCD with 4-line display |
Outputs | 4-20 mA, HART, Modbus (optional) |
Power Supply | 100-240 VAC, 50/60 Hz |
Dimensions (WxHxD) | 130 x 129.5 x 32.8mm |
Weight | 0.24kg |
Operating Temp. | -10 to 55°C |
Ingress Protection | IP65 |
Applications
The EC402-51 is suitable for a wide range of applications, including:
- Water Treatment: Monitoring pH and conductivity in purification systems.
- Chemical Processing: Precise control of reaction processes.
- Pharmaceuticals: Ensuring compliance with strict quality standards.
- Food & Beverage: Maintaining optimal conditions for production.
- Power Plants: Monitoring water quality in boilers and cooling systems.
Compatible Models for Integration
The EC402-51 can be paired with the following Yokogawa sensors and accessories:
- Sensors: PH8E, SC8E, OR8E
- Transmitters: EXAxt450, EXAxt400
- Accessories: YTA110 temperature transmitter, YFGW410 field wireless converter
Installation Instructions
- Mounting: Secure the analyzer on a DIN rail or panel using the provided brackets.
- Wiring: Connect power and signal cables according to the wiring diagram in the manual.
- Sensor Connection: Attach the compatible sensor to the designated input terminals.
- Calibration: Perform initial calibration using standard solutions for accurate measurements.
- Testing: Verify functionality by simulating process conditions.
Ensure the installation environment is free from excessive vibration, dust, and moisture to prolong the device’s lifespan.
Recommended Related Models (Same Series)
Model | Measurement | Accuracy | Dimensions | Weight | Voltage |
---|---|---|---|---|---|
EC402-52 | pH/ORP | ±0.01 pH | 96 x 96 x 135mm | 1.2 kg | 100-240 VAC |
EC402-53 | Conductivity | ±0.5% FS | 96 x 96 x 135mm | 1.2 kg | 100-240 VAC |
EC402-54 | pH/Conductivity | ±0.01 pH | 96 x 96 x 135mm | 1.3 kg | 100-240 VAC |
EC402-55 | ORP/Conductivity | ±1 mV | 96 x 96 x 135mm | 1.2 kg | 100-240 VAC |
EC402-56 | Multi-parameter | ±0.01 pH | 96 x 96 x 135mm | 1.4 kg | 100-240 VAC |
EC402-57 | High Temp. pH | ±0.02 pH | 96 x 96 x 135mm | 1.3 kg | 100-240 VAC |
Popular Yokogawa Models (Other Series)
Model | Type | Key Features | Dimensions | Weight | Voltage |
---|---|---|---|---|---|
EXAxt450 | pH/ORP Transmitter | Dual-channel, HART communication | 144 x 144 x 180mm | 2.1 kg | 100-240 VAC |
EXAxt400 | Conductivity Transmitter | High accuracy, modular design | 144 x 144 x 180mm | 2.0 kg | 100-240 VAC |
YTA110 | Temperature Transmitter | Wireless, compact design | 55 x 55 x 108mm | 0.3 kg | 24 VDC |
YFGW410 | Field Wireless Converter | Supports multiple sensors | 96 x 96 x 135mm | 1.0 kg | 100-240 VAC |
PH8E | pH Sensor | High durability, gel-filled electrode | 12 mm diameter | 0.5 kg | N/A |
SC8E | Conductivity Sensor | Wide range, PTFE body | 12 mm diameter | 0.6 kg | N/A |
OR8E | ORP Sensor | Platinum tip, high stability | 12 mm diameter | 0.5 kg | N/A |
FLXA402 | Multi-analyzer | 4-channel, modular design | 144 x 144 x 180mm | 2.5 kg | 100-240 VAC |
FAQ (Q&A)
Q1: What is the lifespan of the EC402-51?
A1: With proper maintenance, the EC402-51 can operate reliably for 5-10 years, depending on the environment.
Q2: Can the EC402-51 be used in hazardous areas?
A2: Yes, it is available with ATEX and IECEx certifications for hazardous area installation.
Q3: How often should calibration be performed?
A3: Calibration frequency depends on usage, but typically every 1-3 months is recommended for critical applications.
Q4: Is the EC402-51 compatible with third-party sensors?
A4: No, it is optimized for Yokogawa sensors to ensure accuracy and reliability.
Q5: What is the warranty period for this product?
A5: Yokogawa offers a standard 2-year warranty for the EC402-51.
Q6: Can the EC402-51 be integrated with SCADA systems?
A6: Yes, it supports Modbus and HART protocols for seamless SCADA integration.
Yokogawa EC402-51 ESB Bus Coupler Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |