Yokogawa NFCP501-W05 Product Documentation
Product Introduction
The Yokogawa NFCP501-W05 is a high-performance, compact field-mounted signal conditioner designed for industrial process control applications. It provides reliable signal conversion, isolation, and transmission for various process signals, including temperature, pressure, and flow. The device is built to withstand harsh industrial environments, ensuring long-term stability and accuracy.
The NFCP501-W05 is part of Yokogawa’s extensive lineup of signal conditioners, known for their robustness and precision. It is widely used in industries such as oil & gas, chemical, power generation, and water treatment.
Product Advantages
- High Accuracy – Provides precise signal conversion with minimal deviation.
- Isolation – Offers galvanic isolation to prevent ground loops and noise interference.
- Compact Design – Space-saving construction suitable for dense panel installations.
- Durability – Built to withstand extreme temperatures, vibrations, and EMI/RFI interference.
- Easy Configuration – Simple setup via DIP switches or software configuration tools.
- Wide Compatibility – Supports multiple input/output signal types (e.g., 4-20mA, thermocouples, RTDs).
Technical Specifications
Parameter | Specification |
---|---|
Model | NFCP501-W05 |
Input Signal | 4-20mA, Thermocouple (Type K, J, etc.), RTD (Pt100) |
Output Signal | 4-20mA, 1-5V, 0-10V |
Isolation | 1500V AC (input-to-output-to-power) |
Accuracy | ±0.1% of span |
Power Supply | 24V DC (20-30V DC range) |
Operating Temp. | -20°C to +60°C |
Dimensions (W×H×D) | 49.7 x 130 x 146.5 mm |
Weight | 0.6 kg |
Mounting | DIN rail or panel mount |
Certifications | CE, UL, IECEx, ATEX |
Applications
- Process Control Systems – Signal conditioning for PLCs and DCS.
- Temperature Monitoring – Converts thermocouple/RTD signals for control systems.
- Pressure & Flow Measurement – Interfaces with transmitters for accurate signal transmission.
- Hazardous Areas – Suitable for Ex-rated environments (with appropriate certifications).
Compatible Models for Integration
The NFCP501-W05 can be used alongside:
- Yokogawa NFP90 (Field Power Supply)
- Yokogawa NXR202 (Relay Output Module)
- Yokogawa NX100 (Signal Conditioner for RTDs)
- Yokogawa NX-Series (Additional signal conditioning modules)
Installation Instructions
- Mounting – Secure the unit on a DIN rail or panel using the provided clips.
- Wiring – Connect input/output signals and power supply as per the terminal diagram.
- Configuration – Set DIP switches or use Yokogawa’s configuration software for signal type selection.
- Testing – Verify signal accuracy using a calibrated multimeter or process calibrator.
- Enclosure – Ensure proper IP rating if installed in outdoor or harsh environments.
Recommended Related Models (Same Series)
Model | Input Signal | Output Signal | Isolation | Power Supply | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
NFCP501-W10 | 4-20mA, RTD | 4-20mA, 0-10V | 1500V AC | 24V DC | 22.5×100×115 | 200g |
NFCP502-W05 | Thermocouple (Type K) | 1-5V | 1500V AC | 24V DC | 22.5×100×115 | 210g |
NFCP503-W05 | Frequency Input | Relay Output | 1500V AC | 24V DC | 22.5×100×115 | 220g |
NFCP504-W05 | 0-10V Input | 4-20mA | 1500V AC | 24V DC | 22.5×100×115 | 200g |
NFCP505-W05 | RTD (Pt100) | 0-5V | 1500V AC | 24V DC | 22.5×100×115 | 200g |
NFCP506-W05 | Digital Input | Digital Output | 1500V AC | 24V DC | 22.5×100×115 | 210g |
Popular Yokogawa Models (Other Series)
Model | Type | Input/Output | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
YTA510 | Temperature Transmitter | RTD/T/C | 12-30V DC | 44×92×58 | 300g |
EJX110A | Differential Pressure Transmitter | 4-20mA+HART | 10.5-42V DC | 110×155×135 | 2.5kg |
AXF Series | Magnetic Flowmeter | 4-20mA/Pulse | 100-240V AC | Varies by size | 3-15kg |
UTAdvanced | Ultrasonic Level Meter | 4-20mA/RS485 | 24V DC | 150×200×100 | 1.8kg |
FA-M3 | Programmable Controller | Digital/Analog I/O | 24V DC | 90×130×60 | 500g |
DPharp EJA Series | Pressure Transmitter | 4-20mA+HART | 10.5-42V DC | 108×155×135 | 2.3kg |
CX1000 | Paperless Recorder | Multi-input | 100-240V AC | 144×144×150 | 2.0kg |
VigilantPlant | Control System | Modular I/O | 24V DC/AC | Rack-mounted | Varies |
Frequently Asked Questions (FAQ)
Q1: What is the maximum operating temperature for the NFCP501-W05?
A1: The NFCP501-W05 operates reliably within a range of -20°C to +60°C.
Q2: Can this model be used in hazardous areas?
A2: Yes, it is certified for use in Ex zones (check specific certifications like ATEX/IECEx).
Q3: Does it support HART communication?
A3: No, the NFCP501-W05 is a basic signal conditioner and does not support HART protocol.
Q4: What is the typical lifespan of this device?
A4: With proper installation and maintenance, it can last over 10 years in industrial environments.
Q5: Is external calibration required?
A5: Periodic calibration is recommended (annually) for maintaining accuracy.
Q6: Can multiple units be mounted side by side?
A6: Yes, the compact design allows dense installations with proper heat dissipation.