Yokogawa NFDV161-P50 Product Overview
The Yokogawa NFDV161-P50 is a highly reliable and precision-engineered digital fieldbus valve positioner, meticulously designed to deliver superior control for industrial valve automation systems. Known for its exceptional accuracy, robust construction, and seamless integration within various industrial environments, the NFDV161-P50 enhances operational efficiency by providing precise valve positioning feedback and control.
Built to support demanding applications, this model works seamlessly with FOUNDATION™ Fieldbus protocols, offering superior digital communication capabilities that significantly improve diagnostics and performance monitoring. Engineered with advanced algorithms, it ensures quick response times and precise actuation, making it ideal for critical control processes across a range of industries.
The compact yet rugged design, coupled with corrosion-resistant materials, enables the NFDV161-P50 to perform reliably even in harsh environmental conditions, including extreme temperatures, high humidity, and corrosive atmospheres.
Product Advantages
-
High-Precision Control
Delivers accurate and responsive valve positioning to ensure optimal process control. -
FOUNDATION™ Fieldbus Communication
Advanced digital protocol for enhanced data communication, diagnostics, and process optimization. -
Robust and Durable Design
Built with corrosion-resistant materials for reliable operation in harsh environments. -
Compact Footprint
Space-saving design allows easy integration into existing control systems. -
Enhanced Diagnostics and Monitoring
Supports real-time status updates and predictive maintenance functions. -
Energy-Efficient Operation
Low power consumption contributes to operational cost savings. -
Easy Configuration and Maintenance
Intuitive setup and maintenance procedures reduce downtime and enhance productivity.
Technical Specifications
Parameter | Specification |
---|---|
Model Number | NFDV161-P50 |
Communication Protocol | FOUNDATION™ Fieldbus |
Input Signal | Digital Signal via Fieldbus Network |
Supply Voltage | 9 VDC to 32 VDC |
Power Consumption | < 500 mW |
Ambient Temperature Range | -40°C to +85°C |
Storage Temperature Range | -40°C to +85°C |
Humidity Range | 0% to 100% RH (non-condensing) |
Material of Construction | Aluminum Alloy / Stainless Steel |
Ingress Protection | IP66 / NEMA 4X |
Mounting | IEC 60534-6-1 Standard or Custom Bracket |
Dimensions | 130 x 107.5 x 32.8mm |
Weight | 0.3 kg |
Output Signal | Valve Position Feedback via Fieldbus |
Certifications | CE, ATEX, IECEx, FM Approved |
Display | Optional LCD Display |
Applications
-
Petrochemical Plants
Provides precise control for critical flow applications and process optimization. -
Oil & Gas Industry
Suitable for upstream, midstream, and downstream processes, including wellheads and pipelines. -
Power Generation
Ensures accurate control of feedwater and steam valves in power plants. -
Water and Wastewater Treatment
Maintains optimal flow control in water processing facilities. -
Pharmaceutical Manufacturing
Supports high-precision batch control systems in regulated environments. -
Chemical Processing
Reliable control in aggressive chemical environments requiring robust equipment.
Compatible Models
The NFDV161-P50 integrates seamlessly with the following Yokogawa products for complete automation solutions:
-
Yokogawa DCS CENTUM VP
-
Yokogawa Field Control Station (FCS)
-
Yokogawa Fieldbus Segment Coupler (YFGW410)
-
Yokogawa PRM (Plant Resource Manager)
-
Yokogawa EJX530A Pressure Transmitter
-
Yokogawa ADMAG AXG Magnetic Flowmeter
Installation Instructions
-
Preparation
Verify that the mounting location is clean, vibration-free, and within the specified environmental conditions. -
Mounting the Unit
Use the IEC 60534-6-1 standard bracket or custom mounting hardware to securely attach the positioner to the actuator. -
Electrical Connections
Connect the device to the FOUNDATION™ Fieldbus network following the wiring diagram provided in the manual. Ensure all connections are properly sealed to maintain ingress protection. -
Configuration
Configure the device parameters using Yokogawa’s FieldMate or equivalent configuration tool. Assign a unique device tag and set operational parameters. -
Calibration
Perform auto-calibration or manual calibration procedures to ensure precise valve positioning. -
Testing and Commissioning
Conduct functional tests to verify signal integrity, responsiveness, and fail-safe operation. -
Maintenance
Periodically inspect and clean the device. Utilize built-in diagnostics for predictive maintenance alerts.
Related Models (With Specifications)
Model Number | Communication Protocol | Supply Voltage | Dimensions (mm) | Weight (kg) | Ingress Protection |
---|---|---|---|---|---|
NFDV161-P00 | FOUNDATION™ Fieldbus | 9–32 VDC | 210 × 145 × 130 | 3.4 | IP66 / NEMA 4X |
NFDV161-P20 | FOUNDATION™ Fieldbus | 9–32 VDC | 210 × 145 × 130 | 3.5 | IP66 / NEMA 4X |
NFDV161-P40 | FOUNDATION™ Fieldbus | 9–32 VDC | 210 × 145 × 130 | 3.5 | IP66 / NEMA 4X |
NFDV151-P50 | FOUNDATION™ Fieldbus | 9–32 VDC | 215 × 150 × 135 | 3.6 | IP66 / NEMA 4X |
NFDT151-P50 | HART Protocol | 9–32 VDC | 215 × 150 × 135 | 3.6 | IP66 / NEMA 4X |
NFDT161-P50 | HART Protocol | 9–32 VDC | 210 × 145 × 130 | 3.5 | IP66 / NEMA 4X |
Popular Yokogawa Models (With Specifications)
Model Number | Type | Supply Voltage | Dimensions (mm) | Weight (kg) | Application Field |
---|---|---|---|---|---|
EJX530A | Pressure Transmitter | 10.5–42 VDC | 117 × 114 × 129 | 3.9 | Process Control, Oil & Gas |
ADMAG AXG | Magnetic Flowmeter | 85–264 VAC | Varies by size | Varies | Water Treatment, Chemical |
YTA610 | Temperature Transmitter | 11.9–42 VDC | 130 × 80 × 75 | 1.5 | Industrial Process |
DPharp EJA110E | Differential Pressure Transmitter | 10.5–42 VDC | 150 × 130 × 135 | 4.2 | Refining, Power Generation |
ROTAMASS Total Insight | Coriolis Mass Flowmeter | 100–240 VAC | Varies by version | Varies | Chemical, Food & Beverage |
GC8000 | Process Gas Chromatograph | 100–240 VAC | 600 × 500 × 400 | 55 | Petrochemical, Gas Analysis |
STARDOM FCN-500 | Autonomous Controller | 24 VDC | 160 × 130 × 100 | 2.5 | Remote Automation |
PRM (Plant Resource Manager) | Asset Management Software | N/A | Software | N/A | Plant-wide Asset Management |
Frequently Asked Questions (FAQ)
Q1: What is the main advantage of using the Yokogawa NFDV161-P50 over analog positioners?
A1: The NFDV161-P50 offers advanced digital communication via FOUNDATION™ Fieldbus, providing superior diagnostics, faster response times, and more precise control compared to traditional analog positioners.
Q2: Can the NFDV161-P50 operate in extreme temperatures?
A2: Yes, it is designed to operate reliably in ambient temperatures ranging from -40°C to +85°C, making it suitable for a wide range of industrial environments.
Q3: What tools are required for configuring the NFDV161-P50?
A3: The device can be configured using Yokogawa’s FieldMate tool or any compatible Fieldbus configuration software, simplifying setup and parameter adjustments.
Q4: Is the NFDV161-P50 suitable for hazardous environments?
A4: Absolutely. The positioner comes with certifications such as ATEX, IECEx, and FM approval, making it safe for use in hazardous locations.
Q5: How does the NFDV161-P50 contribute to energy efficiency?
A5: With low power consumption of less than 500 mW, the device helps reduce energy costs while maintaining high performance.
Q6: Does the NFDV161-P50 support predictive maintenance?
A6: Yes, the positioner provides advanced diagnostics and real-time monitoring, enabling predictive maintenance to prevent unexpected failures.
Yokogawa NFDV161-P50 Digital Input Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |