Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Yokogawa SAI143-H53 Comprehensive Product Description
Product Introduction
The Yokogawa SAI143-H53 is a high-performance input/output (I/O) module, designed for integration within the CENTUM VP distributed control system (DCS). Built with precision engineering, the SAI143-H53 is specifically developed to handle multiple types of analog inputs, supporting both current and voltage signal ranges. This module ensures accurate signal acquisition, real-time processing, and reliable data communication between field devices and control systems.
The SAI143-H53 is part of Yokogawa’s reputable I/O suite, providing high channel density, superior isolation, and exceptional noise immunity. Its robust design makes it suitable for the most demanding industrial applications, ranging from oil & gas facilities to advanced chemical processing plants.
With seamless plug-and-play integration, advanced diagnostics, and long-term operational reliability, the SAI143-H53 empowers plant operators to achieve superior process visibility and control accuracy.
Product Advantages
-
High Channel Density
Supports multiple input channels within a compact form factor, optimizing cabinet space and reducing installation costs. -
Superior Signal Accuracy
Delivers precise analog signal acquisition for both voltage and current inputs, ensuring high-fidelity data processing. -
Robust Electrical Isolation
Features advanced galvanic isolation between channels and system bus, enhancing operational safety and preventing signal interference. -
Wide Application Compatibility
Compatible with a wide range of sensors and field instruments, increasing system flexibility. -
Enhanced Diagnostics
Built-in diagnostics provide real-time status monitoring, helping to proactively identify and troubleshoot faults. -
Simplified Maintenance
Modular design allows for easy replacement and reduces downtime during maintenance procedures. -
High Reliability and Longevity
Engineered to perform reliably under harsh industrial conditions, including extreme temperatures and vibrations.
Technical Specifications
Parameter | Specification |
---|---|
Model | Yokogawa SAI143-H53 |
Function | Analog Input Module |
Input Signal Type | 4–20 mA, 1–5 V DC |
Number of Channels | 16 channels per module |
Resolution | 16-bit |
Isolation | Galvanic isolation between channels |
Power Supply Voltage | 24 V DC |
Power Consumption | Approx. 4.0 W |
Operating Temperature | -20°C to +70°C |
Storage Temperature | -40°C to +85°C |
Operating Humidity | 5% to 95% RH (non-condensing) |
Dimensions (W x H x D) | 130 x 107.5 x 32.8mm |
Weight | 0.39 kg |
Mounting Method | DIN rail mounting |
Communication Interface | Vnet/IP |
Certification | CE, UL, CSA, ATEX compliant |
Product Applications
-
Oil & Gas Industry
Used for precise monitoring and control of pressure, flow, and temperature in upstream and downstream operations. -
Chemical Processing Plants
Ideal for accurate data acquisition in complex chemical reactions and production lines. -
Power Generation
Supports real-time monitoring of critical electrical parameters to ensure stable power delivery. -
Pharmaceutical Manufacturing
Ensures process accuracy in sensitive environments requiring strict compliance and precision. -
Water and Wastewater Treatment
Provides reliable monitoring of water quality indicators such as pH, turbidity, and flow rates. -
Pulp and Paper Industry
Facilitates efficient control of temperature and flow rates in various stages of production.
Compatible Models
-
Yokogawa SAI143-H53 is compatible with the following Yokogawa system components:
-
ALR121-S00 (Baseplate)
-
ANB10D-420 (Field Terminal Assembly)
-
ADV151-P03 (Processor Module)
-
VPS144-S23 (Power Supply Unit)
-
Vnet/IP Network Switches
-
STARDOM FCN-500 (Controller)
-
These components work seamlessly to ensure system integrity, expandability, and reliable process control.
Installation Instructions
-
Preparation
Ensure that the system power is completely turned off before beginning installation to prevent electrical hazards. -
Mounting
Install the SAI143-H53 module securely on the DIN rail within the control cabinet. Ensure that adequate spacing is provided for ventilation. -
Wiring Connections
Connect field device wiring to the appropriate terminals on the baseplate or terminal block, following the wiring diagrams provided in the manual. -
Power Supply
Connect the module to a stable 24 V DC power supply, verifying polarity to prevent damage. -
Network Configuration
Connect the communication ports to the Vnet/IP network using shielded Ethernet cables. -
System Integration
Configure the module using Yokogawa’s engineering tool (such as PRM or DCS configurator). Assign appropriate I/O channels and calibrate if necessary. -
Testing and Commissioning
Power up the system and perform diagnostics to confirm proper module recognition and communication with the controller.
Related Models (Same Series / Relevant Models)
Model | Description | Channels | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
SAI143-H50 | Analog Input Module | 16 | 24 V DC | 27.9 × 130 × 160 | 340 g |
SAI533-H53 | Analog Input Module (High Speed) | 8 | 24 V DC | 27.9 × 130 × 160 | 330 g |
SAH144-H53 | High Density Analog Module | 32 | 24 V DC | 35 × 130 × 160 | 360 g |
SAI533-H50 | Standard Analog Module | 8 | 24 V DC | 27.9 × 130 × 160 | 330 g |
SAT143-H53 | Temperature Input Module | 16 | 24 V DC | 27.9 × 130 × 160 | 350 g |
SAI144-H53 | Multi-signal Input Module | 16 | 24 V DC | 27.9 × 130 × 160 | 345 g |
Popular Yokogawa Models
Model | Description | Function | Voltage | Dimensions (mm) | Weight |
---|---|---|---|---|---|
AAI141-H50 | Analog Input Module | 4–20 mA Signal Input | 24 V DC | 27.9 × 130 × 160 | 340 g |
ADV551-P03 | Processor Module | Data Processing | 24 V DC | 50 × 150 × 160 | 450 g |
ALR121-S00 | Baseplate | Module Mounting | – | 130 × 150 × 30 | 400 g |
AMN11D | Power Supply Module | Power Distribution | 24 V DC | 40 × 130 × 160 | 420 g |
SAI533-H53 | High-Speed Analog Input Module | Fast Analog Acquisition | 24 V DC | 27.9 × 130 × 160 | 330 g |
STARDOM FCN-500 | Modular Controller | Process Control | 24 V DC | 130 × 180 × 100 | 1.2 kg |
PW402 | Power Supply Unit | System Power Supply | 24 V DC | 75 × 130 × 160 | 900 g |
VJ77 | Configurator Tool | Field Device Setup | USB Powered | Handheld | 500 g |
Frequently Asked Questions (FAQ)
Q1: What type of input signals does the Yokogawa SAI143-H53 support?
A1: The SAI143-H53 supports analog input signals, specifically 4–20 mA and 1–5 V DC signals, making it highly versatile for various field devices.
Q2: Can the SAI143-H53 be used in hazardous environments?
A2: Yes, the module complies with ATEX and other international standards, making it suitable for use in hazardous industrial environments.
Q3: What is the typical installation method for the SAI143-H53?
A3: The module is designed for DIN rail mounting, which simplifies installation and allows for easy integration into control cabinets.
Q4: Does the SAI143-H53 provide channel-to-channel isolation?
A4: Yes, it features galvanic isolation between input channels and between channels and the system bus, ensuring high reliability and safety.
Q5: How is the module configured after installation?
A5: Configuration is performed through Yokogawa’s engineering tools such as PRM or DCS configurators, allowing users to assign channels and perform calibrations.
Q6: What is the expected lifespan of the SAI143-H53 in industrial environments?
A6: Designed for longevity, the SAI143-H53 typically operates reliably for over 10 years under recommended operating conditions.
Yokogawa SAI143-H53 Analog Input Module
Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8615980777398 | |||||||
+8615980777398 | ||||||||
+8615980777398 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |