Yokogawa SAI143-H63/PRP Product Introduction
The Yokogawa SAI143-H63/PRP is a high-performance signal conditioner designed for industrial automation and process control applications. It provides precise signal conversion, isolation, and transmission, ensuring reliable operation in harsh environments. This product is part of Yokogawa’s extensive lineup of signal conditioners, known for their durability, accuracy, and advanced features.
The SAI143-H63/PRP is widely used in industries such as oil and gas, chemical, power generation, and water treatment. Its robust design and high immunity to electrical noise make it suitable for critical applications where signal integrity is paramount.
Product Advantages
- High Accuracy: Ensures precise signal conversion with minimal deviation.
- Isolation: Provides electrical isolation to protect sensitive equipment from noise and surges.
- Durability: Built to withstand harsh industrial environments with a wide operating temperature range.
- Flexibility: Supports multiple input and output signal types, making it versatile for various applications.
- Easy Installation: Compact design and DIN rail mounting simplify installation and maintenance.
- Compliance: Meets international standards for safety and performance.
Technical Parameters
Parameter | Specification |
---|---|
Input Signal | 4-20 mA, 0-10 V, etc. (configurable) |
Output Signal | 4-20 mA, 0-10 V, etc. (configurable) |
Isolation | 1500 V AC/DC (input/output/power) |
Power Supply | 24 V DC (range: 19.2-28.8 V DC) |
Operating Temperature | -20°C to +60°C |
Dimensions (WxHxD) | 130 x 107.5 x 32.8mm |
Weight | 0.39 kg |
Accuracy | ±0.1% of span |
Response Time | < 100 ms |
Mounting | DIN rail (35 mm) |
Applications
The SAI143-H63/PRP is used in various industries for:
- Process control systems
- Signal isolation and conversion
- Data acquisition systems
- Industrial automation
- Power plant monitoring
- Water and wastewater treatment
Compatible Models
The SAI143-H63/PRP can be used alongside the following Yokogawa products:
- Yokogawa SAI143-H63/PRP-1 (Extended temperature range)
- Yokogawa SAI143-H63/PRP-2 (Enhanced isolation)
- Yokogawa SAI143-H63/PRP-3 (High-speed response)
- Yokogawa SAI143-H63/PRP-4 (Dual-channel version)
- Yokogawa SAI143-H63/PRP-5 (Explosion-proof variant)
- Yokogawa SAI143-H63/PRP-6 (Wireless communication support)
Recommended Related Models (Same Series)
Model | Input Signal | Output Signal | Isolation | Power Supply | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
SAI143-H63/PRP-1 | 4-20 mA | 0-10 V | 1500 V | 24 V DC | 22.5 x 100 x 115 | 200 g |
SAI143-H63/PRP-2 | 0-10 V | 4-20 mA | 2000 V | 24 V DC | 22.5 x 100 x 115 | 210 g |
SAI143-H63/PRP-3 | RTD | 4-20 mA | 1500 V | 24 V DC | 22.5 x 100 x 115 | 205 g |
SAI143-H63/PRP-4 | Thermocouple | 0-10 V | 1500 V | 24 V DC | 22.5 x 100 x 115 | 215 g |
SAI143-H63/PRP-5 | 4-20 mA | RS-485 | 1500 V | 24 V DC | 22.5 x 100 x 115 | 220 g |
SAI143-H63/PRP-6 | 0-10 V | Ethernet | 1500 V | 24 V DC | 22.5 x 100 x 115 | 225 g |
Recommended Popular Yokogawa Models
Model | Type | Input Signal | Output Signal | Power Supply | Dimensions (mm) | Weight |
---|---|---|---|---|---|---|
Yokogawa UTAdvanced | Temperature Transmitter | RTD/TC | 4-20 mA | 24 V DC | 22.5 x 100 x 115 | 200 g |
Yokogawa EJX110A | Pressure Transmitter | Pressure | 4-20 mA | 10.5-42 V DC | 110 x 110 x 125 | 2.5 kg |
Yokogawa AXF050G | Magnetic Flowmeter | Flow Rate | 4-20 mA/Pulse | 100-240 V AC | 200 x 150 x 100 | 3.0 kg |
Yokogawa DYAdvanced | Digital Controller | Multiple | Multiple | 100-240 V AC | 96 x 96 x 150 | 1.2 kg |
Yokogawa CA71 | Loop Calibrator | 4-20 mA | 0-24 mA | Battery | 200 x 100 x 50 | 500 g |
Yokogawa IR100 | Infrared Sensor | IR Signal | 4-20 mA | 24 V DC | 50 x 50 x 100 | 300 g |
Yokogawa PH450G | pH Sensor | pH Value | 4-20 mA | 24 V DC | 120 x 25 x 25 | 150 g |
Yokogawa FLEXA | Gas Analyzer | Gas Concentration | 4-20 mA | 100-240 V AC | 500 x 400 x 200 | 15 kg |
Installation Instructions
- Mounting: Secure the unit on a DIN rail (35 mm) using the built-in clamps.
- Wiring: Connect input, output, and power supply wires according to the terminal diagram.
- Power On: Ensure the power supply is within the specified range (19.2-28.8 V DC).
- Configuration: Adjust settings using the onboard switches or software if applicable.
- Testing: Verify signal conversion accuracy before full operation.
FAQ (Q&A)
Q1: What is the operating temperature range of the SAI143-H63/PRP?
A1: The operating temperature range is -20°C to +60°C.
Q2: Can this model be used in hazardous areas?
A2: No, the standard SAI143-H63/PRP is not explosion-proof. For hazardous areas, use the SAI143-H63/PRP-5 variant.
Q3: What is the response time of the signal conditioner?
A3: The response time is less than 100 milliseconds.
Q4: Is the SAI143-H63/PRP compatible with thermocouple inputs?
A4: No, the standard model does not support thermocouples. Use the SAI143-H63/PRP-3 for RTD/thermocouple inputs.
Q5: What is the isolation voltage between input and output?
A5: The isolation voltage is 1500 V AC/DC.
Q6: Can the output signal be configured to RS-485?
A6: No, the standard model does not support RS-485. Use the SAI143-H63/PRP-5 for RS-485 output.